EAE-LOGO

EAE KMG103 R4.0 KNX PSU and KNX-Modbus TCP Gateway

EAE-KMG103-R4-0-KNX-PSU-and-KNX-Modbus-TCP-Gateway-PRODUCT

Product Specifications:

  • Type of protection: CE
  • Safety class: IP 20
  • Over voltage category: EN 60 529 II
  • Pollution degree: EN 61 140 III
  • Main supply: EN 60 664-1
  • Output:
    • Input voltage (220 V): 150-275V AC, 50-60Hz
    • Input voltage (110 V): 85-160V AC, 50-60Hz
    • Power consumption: 7 W
  • Connections:
    • KNX BUS: 30 VDC +1/-2 V, (choke)
    • KNX AUX: 30 VDC
  • Display elements: Link/Act, KNX LED, Modbus LED, Occupancy LED,Configuration LED
  • Operating elements: Reset/Factory Reset Button, Power Led,Overload Led, Reset Button
  • Installation: 35mm DIN rail mount (EN 60 715 TH 35-75)
  • Temperature range: Operation – Max. 93% non condense, Storage – Max. 93% non condense
  • Dimensions: H x W x L – 66 mm x 108 mm x 90 mm

Product Usage Instructions

Installation:

  1. Mount the device on a 35mm DIN rail according to the provided guidelines.
  2. Connect the necessary cables to their respective ports as indicated in the manual.

Operation:

  1. Ensure a stable power supply within the specified input voltage range.
  2. Observe the various LEDs to monitor device status and connectivity.

Cleaning:
If the device gets dirty, use a dry cloth for cleaning. Avoid using wet cloths, caustics, or solvents.

Commissioning:
The device can only be programmed using the KMG Configurator Software available for download on the manufacturer’s website.

General Description

  • EAE KMG103 can be used to control and monitor KNX installations via SCADA visualization software.
  • IP address of device can be given by DHCP server or by manual configuration.
  • EAE KMG103 features a KNG IP interface that supports up to 4 simultaneous KNXnet/IP tunneling connections.
  • EAE KMG103 includes patent-pending logic controller that enables room energy saver system without using card holder.
  • Device has 2 physical inputs for door and window sensing.
  • EAE KMG103 has built-in two models which are 320mA or 640 mA KNX bus power supply for KNX devices.
  • KNX Power supply output is short-circuit and overload protected.
  • Power, overload and reset statuses are indicated with three different LED indicators.
  • Power supply can be restarted by pressing reset button on the device.

Device Peripherals

EAE-KMG103-R4-0-KNX-PSU-and-KNX-Modbus-TCP-Gateway-FIG- (1)

No Function No Function
1 RJ45/Ethernet Connection 9 Reset/Factory Reset Button
2 Ethernet Connection/Transmission LED 10 KNX Connection Terminal
3 KNX Connection/Transmission LED 11 Dry Contact Inputs (a, b, c)
4 Modbus Connection/Transmission LED 12 Power LED
5 Occupancy State LED 13 Overload LED
6 PC Configurator Software Connection LED 14 Physical address label
7 Model Name Label 15 Power Supply Input
8 KNX Reset LED 16 KNX Auxiliary Output – 30V

Operating LEDs

Link/Act
It turns on steady when there is an Ethernet connection and flashes during data transfer.

KNX LED
During the initial reading of all KNX group objects, it flashes periodically. It then lights up constantly. Flashes during KNX communication.

Modbus LED
Steady when a Modbus client is connected to the device. It flashes periodically during Modbus communication. It turns off when the Modbus client connection is lost.

Occupancy LED
Indicates the Room Presence status. When KMG103 determines that the room is occupied, LED turns on steadily. When KMG103 determines that the room is empty, LED turns off.

Configuration LED
Steady when a client is connected to the configuration server. It turns off when the client disconnected from configuration server. It flashes periodically while communicating with the configuration server.

Cleaning

If device becomes dirty, only a dry cloth can be used for cleaning. It is not suitable to use wet cloths, caustics and solvents.

Commissioning
Device can be programmed by KMG Configurator Software only. Software can be downloaded in our website.

Technical Data

Type of protection IP 20 EN 60 529
Safety class II EN 61 140
Over voltage

category

III EN 60 664-1
Pollution

degree

2 EN 60 664-1
Main supply Input voltage (220 V) Input voltage (110 V)

Power consumption

150-275V AC, 50-60Hz

85-160V AC, 50-60Hz

7 W

Output KNX BUS KNX AUX

BUS + AUX Total Current

30 VDC +1/-2 V, (choke)

30 VDC

640 mA / 320 mA

  Short-circuit current for PSU320

Short-circuit current for PSU640

1 A

1,5 A

Connections IP Line RJ45 socket for 10/100BaseT
 

 

 

 

Display elements

Link/Act KNX

Modbus Occupancy Configuration Power

 

Overload

Ethernet Connection KNX Connection Modbus Connection Occupancy Status

Conf. Software Connection St.

Led on green if there is mains voltage (110V or 220V AC)

Led on red if the current output (KNX +

AUX) is above 320 or 640mA

Operating

elements

Reset Button

(for KNX Line reset)

 
Installation 35mm DIN rail mount EN 60 715 TH 35-75
Temperature

range

Operation

Storage

-5° C + 45° C

-20° C + 60° C

Humidity   Max. 93 % non condense
Dimensions H x W x L Width W in mm

Width W in units 18 mm

66 mm x W x 90 mm 108 mm

6 modules

Box Plastic PA66 housing

grey

 
 

CE

in accordance with EMC and low voltage guidelines

Device complies with, EN 50090-2-2, IEC 6

 

 

0664-1

Technical Drawings

EAE-KMG103-R4-0-KNX-PSU-and-KNX-Modbus-TCP-Gateway-FIG- (2)

©EAE Technology
Ikitelli Org. San. Bol. Ziya Gokalp Mah. Eski Turgut Ozal Cad.
No: 20, 34490 Basaksehir/Istanbul Tel: +90 212 549 97 13

www.eaetechnology.com

FAQs

Can the device be used without the KMG Configurator Software?

No, the device can only be programmed using the KMG Configurator Software.

What should I do if the Overload LED turns on?

If the Overload LED turns on, it indicates that the current output is above the specified limit. Check for any excessive load or short circuits and rectify them.