DWIN-logo

DWIN DT322X220034 DT Analog Camera Screen

DWIN-DT322X220034-DT-Analog-Camera-Screen-produt

Application Introduction

DT series analog camera screen products use T5L ASIC as the main control chip, combined with T9-10videodecoding module as a co-processor, to achieve efficient video signal decoding and processing, suitable for AHD and CVBS high-definition analog cameras. Meet the needs of different industries for high-definition video displays.

DWIN-DT322X220034-DT-Analog-Camera-Screen-

Product Features

  1. Supports single channel 1080P high-definition AHD camera display, or dual channel 720PAHD camera display on the same screen.
  2. Supports two CVBS cameras switching display.
  3. Supports full-screen, picture-in-picture, floating icon, and floating character display effects.
  4. Support camera zooming, screenshot saving, rotating mirror, and other functions.
  5. The frame rate for image transmission is 24 frames/s, resulting in smooth and high-definition images.
  6. Support customized video recording function.

Product Selection

 

Model

 

Size

Resolution on LCD

Type

Touch Type  

Color

Operating Voltage

V

Operating Temperature

(℃)

DT322X220034 Z240201A  

4.3

 

800*480

 

IPS

 

No touch

 

24-bit,16.7M

 

9~36

 

-20~70

DT322X220034 Z240201B  

4.3

 

800*480

 

IPS

Resistive touch  

24-bit,16.7M

 

9~36

 

-20~70

DT322X220034 Z240201C  

4.3

 

800*480

 

IPS

Capacitive touch  

24-bit,16.7M

 

9~36

 

-20~70

DT322X220034 Z240201D  

7.0

 

1024*600

 

IPS

 

No touch

 

24-bit,16.7M

 

9~36

 

-20~70

DT322X220034 Z240201E  

7.0

 

1024*600

 

IPS

Resistive touch  

24-bit,16.7M

 

9~36

 

-20~70

DT322X220034 Z240201F  

7.0

 

1024*600

 

IPS

Capacitive touch  

24-bit,16.7M

 

9~36

 

-20~70

DT322X220034 Z240201G  

7.0

 

800*480

 

TN

 

No touch

 

24-bit,16.7M

 

9~36

 

-20~70

DT322X220034 Z240201H  

7.0

 

800*480

 

TN

Resistive touch  

24-bit,16.7M

 

9~36

 

-20~70

DT322X220034 Z240201I  

7.0

 

800*480

 

TN

Capacitive touch  

24-bit,16.7M

 

9~36

 

-20~70

DT322X220034 Z240201J  

10.1

 

1024*600

 

IPS

 

No touch

 

24-bit,16.7M

 

9~36

 

-20~70

DT322X220034 Z240201K  

10.1

 

1024*600

 

IPS

Resistive touch  

24-bit,16.7M

 

9~36

 

-20~70

DT322X220034 Z240201L  

10.1

 

1024*600

 

IPS

Capacitive touch  

24-bit,16.7M

 

9~36

 

-20~70

DT322X220034 Z240201M  

7.0

 

1280*800

 

IPS

 

No touch

 

24-bit,16.7M

 

9~36

 

-20~70

DT322X220034 Z240201N  

7.0

 

1280*800

 

IPS

Resistive touch  

24-bit,16.7M

 

9~36

 

-20~70

DT322X220034 Z240201O  

7.0

 

1280*800

 

IPS

Capacitive touch  

24-bit,16.7M

 

9~36

 

-20~70

Analog camera screen selection table

System Variable Interface Description
DT series analog camera screen is controlled through the system variable interface (0x0500~0x05BF)reserved by the DGUS system.

Variable space first address  

Definition

Length (word)  

Description

 

 

0x0500

 

 

camera_resolution

 

 

3

D5:4: 0x5AA5, start configuration. Clear it to zero after execution.

D3:2: Represents the resolution in the X direction. D1:0: Represents the resolution in the Y direction.

 

0x0503

 

camera_mirror

 

1

D1: 0x5A, set the image. Clear it to zero after execution. D0: 0=not mirrored, 1=mirrored.
 

0x0504

 

camera_rotate

 

1

D1: 0x5A, start configuration. Clear it to zero after execution.

D0: Rotation angle, 0=0 °, 1=90 °, 2=180 °, 3=270 °.

 

 

0x0505

 

 

camera_set

 

 

1

D1: 0x5A, start configuration. Clear it to zero after execution.

D0: 0x00,close all; 0x01, open channel 1;

0x02, open channel 2; 0x03, open all channels.

 

0x0506

 

camera_screenshot

 

1

D1: 0x5A, start screenshot saving. Clear it to zero after execution.

D0: 0x01, channel 1. 0x02, channel 2.

 

 

 

 

0x0507

 

 

 

 

get_screenshot

 

 

 

 

1

D1: 0x5A=View the image of channel 1.

0xAA=View the image of channel 1, and send it via serial port.

0x5B=View the image of channel 2.

0xAB=View the image of channel 2 and send it via serial port. Clear it to zero after execution.

D0: 00=view in reverse order, 01=view in order.

 

 

 

 

 

 

0x0508

 

 

 

 

 

 

set_camera_type

 

 

 

 

 

 

1

D1: 0x5A=Start setting, clear it to zero after execution (if N5 cannot automatically recognize the camera, it can be manually set by changing the interface).

D0: Corresponding setting data.

0x01=N-mode of CVBS. 0x02=P-mode of CVBS. 0x0A=AHD 720P.

0x10= AHD_1080P.

Please note that setting up the camera may cause the kernel to restart. The factory default of the camera is AHD_1080P mode, which can be set only once when powered on.

Variable space first address  

Definition

Length (word)  

Description

 

 

 

 

 

 

 

 

0x0509

 

 

 

 

 

 

 

 

set_n5_reg

 

 

 

 

 

 

 

 

3

D5: 0x5A=Start setting, clear it to zero after execution. D4: Command type.

0xFF =Query the N5 register, and output via R11 UART 0, D3 is valid.

0xEE =Set the N5 register, D3-D0 are valid. 0x5A=Set the actual position, D3-D0 are valid.

D3: 0xEE=Register address 0.

0xFF=Return of the query, 0-255. 0x5A= X high byte of the screenshot.

D2: 0xEE=Set value 0.

0x5A=X low byte of the screenshot.

D1: 0xEE=Register address 1.

0x5A=Y high byte of the screenshot.

D0: 0xEE=Set value 1.

0x5A=Y low byte of the screenshot.

 

 

 

 

0x050C

 

 

 

 

camera_auto_config

 

 

 

 

1

D1: 0x5A=When the camera is turned on, the image resolution is automatically set according to the size of the interface controls. The other value is invalid.

D0: 0x5A=The function of automatically opening the camera is not processed when switching pages. Other value=The function of automatically opening the camera is processed.

0x050D reserved 21 Undefined.
0x051E camera_state 1 D1:0: 0x00=Close all, 0x01=Open channel 1, 0x02=Open

channel 2, 0x03=Open all channels. Read only.

 

 

 

0x051F

 

 

 

R11_state

 

 

 

1

D1: 5A= R11 is started.

Other value=Not started. At this time, the 0x500- 0x51D settings will not be processed. Read only.

D0: The camera mode is activated by R11, with the same type as 0x508, which is only valid when D1 is 5A.Read only.

 

0x0520-0x053F

 

camera_driver_info

 

32

The mapping location of the memory used by the camera driver .Read only.
 

0x0540-0x055F

 

camera1_display_size

 

32

Data transmit control. Its size is the same as the control of camera 1.
 

0x0560-0x057F

 

camera2_display_size

 

32

Data transmit control. Its size is the same as the control of camera 2.
0x0580-0x059F camera1_display_sp 32 Icon overlay, SP of display control for camera 1, VP: FF00.
0x05A0-0x05BF camera2_display_sp 32 Icon overlay, SP of display control for camera 2 ,VP: FF00.

System Variable Interface Definition
The functions corresponding to each system variable address used by the analog camera are shown in the following table.

Note

  1. If you need to view the saved pictures, turn off all cameras.DT322X220034 DT Analog Camera Screen-FIG (1)
  2. Save the screenshot to the SD card. Create folders “1” and “2” in the root directory to save the screscreenshotschannel 1 and channel 2 respectively.DT322X220034 DT Analog Camera Screen-FIG (2)
  3. Please use the CFG file to enable the verification function of UART 2 and UART
  4. CFGfile canbe modified by using the DGUS tool, as shown in the following figure.

Application Instance
For example, adjusting the resolution through the system variable interface 0x0500 can be achieved by sending commands through the serial port or using DGUS “Return Key Code” control.

  1. Serial port command. 82/83 command: 5AA5 09 82 0500 5AA5 0320 01E0
  2. Command meaning: Frame header Command length 82 (write variable space)
  3. SySystem variableddressStartresolution processing once Resolution in X and Y direction
    Note: After the serial port command is issued, the camera screen will be adjusted to 800 * 480.

DGUS control

DT322X220034 DT Analog Camera Screen-FIG (3)

DT322X220034 DT Analog Camera Screen-FIG (4)

  1. The resolution in the X and Y directions can be modified through the “Variables Input” control, and the parameter settings refer to the following figure.DT322X220034 DT Analog Camera Screen-FIG (5)
  2. Making the resolution effective can be achieved through the “Return Key Code” control, with parameter settings shown in the following figure.

Camera Interface DGUS Development

The DGUS project simulating the camera interface requires the use of two controls: “Data transmit” and”Icon Overlay”.Takeg the camera 1 set as an example, Overlay and placeDT322X220034 DT Analog Camera Screen-FIG (6)  DT322X220034 DT Analog Camera Screen-FIG (7)together, and refer to the following content to set the control parameters. The predefined data “5AA5” in the “Data transmit” control means that the camera will automatically open upon entering the page, while the rest of the values aren’t automatically turned on. It is noted that the display area size of the two controls should be consistent.

DT322X220034 DT Analog Camera Screen-FIG (8)DT322X220034 DT Analog Camera Screen-FIG (9)

Revision Records

Version Revise Date Content Editor
V1.0 2024-07-15 First Edition Xu Ying
V1.1 2024-08-19 Add the description about the CVBS camera Xu Ying

Please contact us if you have any questions about the use of this document or our products, or if youwouldliketoknow the latest information about our products:

Thank you all for your continuous support of DWIN, and your approval is the driving force of our progress!