DWIN DT322X220034 DT Analog Camera Screen
Application Introduction
DT series analog camera screen products use T5L ASIC as the main control chip, combined with T9-10videodecoding module as a co-processor, to achieve efficient video signal decoding and processing, suitable for AHD and CVBS high-definition analog cameras. Meet the needs of different industries for high-definition video displays.
Product Features
- Supports single channel 1080P high-definition AHD camera display, or dual channel 720PAHD camera display on the same screen.
- Supports two CVBS cameras switching display.
- Supports full-screen, picture-in-picture, floating icon, and floating character display effects.
- Support camera zooming, screenshot saving, rotating mirror, and other functions.
- The frame rate for image transmission is 24 frames/s, resulting in smooth and high-definition images.
- Support customized video recording function.
Product Selection
Model |
Size |
Resolution on | LCD
Type |
Touch Type |
Color |
Operating Voltage
(V) |
Operating Temperature
(℃) |
DT322X220034 Z240201A |
4.3 |
800*480 |
IPS |
No touch |
24-bit,16.7M |
9~36 |
-20~70 |
DT322X220034 Z240201B |
4.3 |
800*480 |
IPS |
Resistive touch |
24-bit,16.7M |
9~36 |
-20~70 |
DT322X220034 Z240201C |
4.3 |
800*480 |
IPS |
Capacitive touch |
24-bit,16.7M |
9~36 |
-20~70 |
DT322X220034 Z240201D |
7.0 |
1024*600 |
IPS |
No touch |
24-bit,16.7M |
9~36 |
-20~70 |
DT322X220034 Z240201E |
7.0 |
1024*600 |
IPS |
Resistive touch |
24-bit,16.7M |
9~36 |
-20~70 |
DT322X220034 Z240201F |
7.0 |
1024*600 |
IPS |
Capacitive touch |
24-bit,16.7M |
9~36 |
-20~70 |
DT322X220034 Z240201G |
7.0 |
800*480 |
TN |
No touch |
24-bit,16.7M |
9~36 |
-20~70 |
DT322X220034 Z240201H |
7.0 |
800*480 |
TN |
Resistive touch |
24-bit,16.7M |
9~36 |
-20~70 |
DT322X220034 Z240201I |
7.0 |
800*480 |
TN |
Capacitive touch |
24-bit,16.7M |
9~36 |
-20~70 |
DT322X220034 Z240201J |
10.1 |
1024*600 |
IPS |
No touch |
24-bit,16.7M |
9~36 |
-20~70 |
DT322X220034 Z240201K |
10.1 |
1024*600 |
IPS |
Resistive touch |
24-bit,16.7M |
9~36 |
-20~70 |
DT322X220034 Z240201L |
10.1 |
1024*600 |
IPS |
Capacitive touch |
24-bit,16.7M |
9~36 |
-20~70 |
DT322X220034 Z240201M |
7.0 |
1280*800 |
IPS |
No touch |
24-bit,16.7M |
9~36 |
-20~70 |
DT322X220034 Z240201N |
7.0 |
1280*800 |
IPS |
Resistive touch |
24-bit,16.7M |
9~36 |
-20~70 |
DT322X220034 Z240201O |
7.0 |
1280*800 |
IPS |
Capacitive touch |
24-bit,16.7M |
9~36 |
-20~70 |
Analog camera screen selection table
System Variable Interface Description
DT series analog camera screen is controlled through the system variable interface (0x0500~0x05BF)reserved by the DGUS system.
Variable space first address |
Definition |
Length (word) |
Description |
0x0500 |
camera_resolution |
3 |
D5:4: 0x5AA5, start configuration. Clear it to zero after execution.
D3:2: Represents the resolution in the X direction. D1:0: Represents the resolution in the Y direction. |
0x0503 |
camera_mirror |
1 |
D1: 0x5A, set the image. Clear it to zero after execution. D0: 0=not mirrored, 1=mirrored. |
0x0504 |
camera_rotate |
1 |
D1: 0x5A, start configuration. Clear it to zero after execution.
D0: Rotation angle, 0=0 °, 1=90 °, 2=180 °, 3=270 °. |
0x0505 |
camera_set |
1 |
D1: 0x5A, start configuration. Clear it to zero after execution.
D0: 0x00,close all; 0x01, open channel 1; 0x02, open channel 2; 0x03, open all channels. |
0x0506 |
camera_screenshot |
1 |
D1: 0x5A, start screenshot saving. Clear it to zero after execution.
D0: 0x01, channel 1. 0x02, channel 2. |
0x0507 |
get_screenshot |
1 |
D1: 0x5A=View the image of channel 1.
0xAA=View the image of channel 1, and send it via serial port. 0x5B=View the image of channel 2. 0xAB=View the image of channel 2 and send it via serial port. Clear it to zero after execution. D0: 00=view in reverse order, 01=view in order. |
0x0508 |
set_camera_type |
1 |
D1: 0x5A=Start setting, clear it to zero after execution (if N5 cannot automatically recognize the camera, it can be manually set by changing the interface).
D0: Corresponding setting data. 0x01=N-mode of CVBS. 0x02=P-mode of CVBS. 0x0A=AHD 720P. 0x10= AHD_1080P. Please note that setting up the camera may cause the kernel to restart. The factory default of the camera is AHD_1080P mode, which can be set only once when powered on. |
Variable space first address |
Definition |
Length (word) |
Description |
0x0509 |
set_n5_reg |
3 |
D5: 0x5A=Start setting, clear it to zero after execution. D4: Command type.
0xFF =Query the N5 register, and output via R11 UART 0, D3 is valid. 0xEE =Set the N5 register, D3-D0 are valid. 0x5A=Set the actual position, D3-D0 are valid. D3: 0xEE=Register address 0. 0xFF=Return of the query, 0-255. 0x5A= X high byte of the screenshot. D2: 0xEE=Set value 0. 0x5A=X low byte of the screenshot. D1: 0xEE=Register address 1. 0x5A=Y high byte of the screenshot. D0: 0xEE=Set value 1. 0x5A=Y low byte of the screenshot. |
0x050C |
camera_auto_config |
1 |
D1: 0x5A=When the camera is turned on, the image resolution is automatically set according to the size of the interface controls. The other value is invalid.
D0: 0x5A=The function of automatically opening the camera is not processed when switching pages. Other value=The function of automatically opening the camera is processed. |
0x050D | reserved | 21 | Undefined. |
0x051E | camera_state | 1 | D1:0: 0x00=Close all, 0x01=Open channel 1, 0x02=Open
channel 2, 0x03=Open all channels. Read only. |
0x051F |
R11_state |
1 |
D1: 5A= R11 is started.
Other value=Not started. At this time, the 0x500- 0x51D settings will not be processed. Read only. D0: The camera mode is activated by R11, with the same type as 0x508, which is only valid when D1 is 5A.Read only. |
0x0520-0x053F |
camera_driver_info |
32 |
The mapping location of the memory used by the camera driver .Read only. |
0x0540-0x055F |
camera1_display_size |
32 |
Data transmit control. Its size is the same as the control of camera 1. |
0x0560-0x057F |
camera2_display_size |
32 |
Data transmit control. Its size is the same as the control of camera 2. |
0x0580-0x059F | camera1_display_sp | 32 | Icon overlay, SP of display control for camera 1, VP: FF00. |
0x05A0-0x05BF | camera2_display_sp | 32 | Icon overlay, SP of display control for camera 2 ,VP: FF00. |
System Variable Interface Definition
The functions corresponding to each system variable address used by the analog camera are shown in the following table.
Note
- If you need to view the saved pictures, turn off all cameras.
- Save the screenshot to the SD card. Create folders “1” and “2” in the root directory to save the screscreenshotschannel 1 and channel 2 respectively.
- Please use the CFG file to enable the verification function of UART 2 and UART
- CFGfile canbe modified by using the DGUS tool, as shown in the following figure.
Application Instance
For example, adjusting the resolution through the system variable interface 0x0500 can be achieved by sending commands through the serial port or using DGUS “Return Key Code” control.
- Serial port command. 82/83 command: 5AA5 09 82 0500 5AA5 0320 01E0
- Command meaning: Frame header Command length 82 (write variable space)
- SySystem variableddressStartresolution processing once Resolution in X and Y direction
Note: After the serial port command is issued, the camera screen will be adjusted to 800 * 480.
DGUS control
- The resolution in the X and Y directions can be modified through the “Variables Input” control, and the parameter settings refer to the following figure.
- Making the resolution effective can be achieved through the “Return Key Code” control, with parameter settings shown in the following figure.
Camera Interface DGUS Development
The DGUS project simulating the camera interface requires the use of two controls: “Data transmit” and”Icon Overlay”.Takeg the camera 1 set as an example, Overlay and place
together, and refer to the following content to set the control parameters. The predefined data “5AA5” in the “Data transmit” control means that the camera will automatically open upon entering the page, while the rest of the values aren’t automatically turned on. It is noted that the display area size of the two controls should be consistent.
Revision Records
Version | Revise Date | Content | Editor |
V1.0 | 2024-07-15 | First Edition | Xu Ying |
V1.1 | 2024-08-19 | Add the description about the CVBS camera | Xu Ying |
Please contact us if you have any questions about the use of this document or our products, or if youwouldliketoknow the latest information about our products:
- Customer service Tel: +86 400 018 9008
- Customer service email: dwinhmi@dwin.com.cn
- DWIN Developer Forum: https://forums.dwin-global.com/
Thank you all for your continuous support of DWIN, and your approval is the driving force of our progress!
Documents / Resources
![]() |
DWIN DT322X220034 DT Analog Camera Screen [pdf] User Guide DT322X220034 DT Analog Camera Screen, DT322X220034, DT Analog Camera Screen, Analog Camera Screen, Camera Screen |