Diablo-logo

Diablo DSP-10-LV Loop Detector

Diablo-DSP-10-LV-Loop-Detector-product

WIRING
The pin assignments for the detector and the optional wiring harness are:

PinWire ColorFunction
1BlackDC + or AC Line
2WhiteDC – or AC Neutral
3OrangeRelay B N.O.
4GreenChassis Ground
5YellowRelay A Common
6BlueRelay A N.O.
PinWire ColorFunction
7GrayLoop
8BrownLoop
9RedRelay B Common
10Pink or White/BlackRelay A N.C.
11Violet or White/RedRelay B N.C.

DIP SWITCHES

1Function
OFFDetect Immediately on Entry
ON2 Second Detect Delay on Entry
23Function
OFFOFFNo Extension
ONOFF2 Second Extension Time
OFFON5 Second Extension Time
ONON10 Second Extension Time
4Function
OFFNormal Sensitivity
ONSensitivity Boost During Detect
56Function
OFFOFFRelay B is Presence
ONOFFRelay B is an “Entry” Pulse
OFFONRelay B is an “Exit” Pulse
ONONRelay B is a “Fail” Condition
56Function
OFFOFFRelay B is Presence
ONOFFRelay B is an “Entry” Pulse
OFFONRelay B is an “Exit” Pulse
ONONRelay B is a “Fail” Condition
8Function
OFFInductive Loop
ONFree Exit Probe (Magnetometer)
910Function
OFFOFFHighest Frequency
ONOFFMedium Highest Frequency
OFFONMedium Lowest Frequency
ONONLowest Frequency

SENSITIVITY

The factory default is 5 and should work for most installations.

Setting0123456789
%ΔL/L0.480.320.240.160.120.080.060.040.030.02
Response70 ms ± 10 ms140 ms ± 20 ms

INDICATORS

Green Power LED
Steady on when operating normally. See fault table for a flashing condition.

FaultDisplay for Current FaultDisplay for Prior Fault
Low Voltage2 Hz with 50% duty cycleNONE
Open Sensor1 flash ON every 2 seconds1 flash OFF every 2 seconds
Shorted Sensor2 flashes ON every 2 seconds2 flashes OFF every 2 seconds
Large Change3 flashes ON every 2 seconds3 flashes OFF every 2 seconds

Red Detect A LED
The LED will turn on when a vehicle is over the loop detection area. If delay is programmed, the LED will blink slowly during the delay interval. If extension is programmed, the LED will blink fast during the extension interval.

FAIL-SAFE or FAIL-SECURE

There are three jumpers internal to the detector that are used to select Fail-Safe or Fail-Secure modeof operation for the Relay A output. This setting determines what states the relay output should be in if a loop failure is detected. Fail-Safe operation has the relay activated. Fail-Secure has the relay deactivated. Most applications that are not high security will use the Fail-Safe mode of operation. The detector is shipped in the Fail-Safe mode from the factory. Additional information is available at the Diablo Controls website www.diablocontrols.com or contact technical support at 866-395-6677.