DEVI 140F1172 Programmable Timer Thermostat

Specifications
- Product Name: DEVIregTM Solo (White)
- Type: Energy-efficient programmable indoor thermostat
- Control Modes: Floor, Room + Floor, only Room*, Power regulation* (*available ONLY for concrete floor construction with tiles flooring!)
- Modulation: Pulse Width Modulation (PWM)
- Mounting: Wall mounting in standard EU boxes (in and on wall)
- Frame System Compatibility: 55×55 (inner geometry) framing systems
- Features: Designed for total heating and comfort heating control.
Introduction
The DEVIreg™ Solo is a thermostat for use with electric floor heating. The thermostat has multiple control modes: Floor, Room + Floor, only Room*, and Power regulation*. The thermostat has Pulse Width Modulation which provides an efficient way of controlling your electric floor heating system. *available ONLY for concrete floor construction with tiles flooring! The thermostat is specifically designed for wall mounting in standard EU boxes, in and on wall, and can be used for control of total heating as well as comfort heating of the room. The thermostat supports a selection of commonly used frame systems for 55×55 (inner geometry) framing systems. Among others, the thermostat has the following features and advantages:
- ECO design LOT20 compliance.
- A color touchscreen display.
- User friendly all-in-one setup from the thermostat.
- Compatible with multiple 3rd party NTC sensors.
- Support for 55×55 mm like frame systems.
- Manual sensors temperature calibration.
- Fully standalone operation – no mobile apps, no connectivity dependencies.
Box contents


Installation guide
Before beginning installation, please ensure that all the following items are included in the box:
- Front display of the thermostat, 1 pc.
- Power supply, 1 pc.
- Frame 55×55 mm, 1 pc.
- Floor sensor, DEVI 15 kOhm @ 25 °C, 3 m
- Installation guide, 1 pc.
Note: If any items are missing or damaged, please contact customer support before installation.
Installation guideline
Thermostat placement
Install the thermostat on the wall at an appropriate height (usually 150 cm).
It is always recommended to install a floor sensor but MANDATORY for wooden or similar materials floor constructions.
DO NOT place the thermostat in a place where it is exposed to direct sunlight or heating appliances.
DO NOT install the thermostat in direct wet areas (Zones 0, 1 and 2). Always follow local regulations regarding IP classes; this doesn’t mean that the thermostats can’t be installed in bathrooms.
DO NOT place the thermostat on the inside of a poorly insulated exterior wall.
DO NOT install the thermostat closer than 50 cm from window and door openings.
Floor sensor and floor constructions
Insert the floor sensor into the conduit pipe and close the end part. The bending radius of the conduit pipe must be >50 mm.
Make sure the floor temperature sensor is positioned midway between the two heating cables at the same level.
ALWAYS use the floor sensor for wooden or similar materials floor constructions!
Concrete floor constructions
Wooden floor constructions
ALWAYS use the floor sensor for wooden or similar materials oor constructions!
Wire connection
- Make sure that the electric circuit is de-energized, turn off all pole disconnectors.
- Connect the wires according to the wiring diagram on back of the thermostat power supply.

- Ensure that the terminals are properly fastened and wires are securely connected.

- The screen/PE wire from the electric heating element must be connected to the PE wire from the main power supply using a separate connector.
After completing the electrical installation, turn on the all-pole switch (fuse).
Thermostat installation
- Install the thermostat power supply to the wall terminal box using screws in at least 2 of the marked holes on the power supply unit.
Make sure all pole switches are off and there is no power.
Note: place the thermostat according to the UP arrow.
- Remove the small plastic strip on the back of the front display to activate the battery backup feature.

- Attach the Front display to the frame. After that, attach these 2 parts to the power supply, pressing lightly until all parts are firmly connected.

- The assembled thermostat with all the parts looks like the picture below.

- To remove the Front display, use a narrow tool, inserting it into the slot located on the bottom of the front, and tilting the tool downwards.

User guide
Your thermostat is now ready to use. Follow the on-screen instructions to set it up when the thermostat is activated for the first time.
During the welcome screen, the thermostat checks the system for errors. If any errors appear, please refer to the ERRORS page.
- LANGUAGE Select a language from the list and click the button
in the upper right corner to confirm.
- TIME Tap the hours/minutes and use the
and
arrows to set the time. Tap to confirm .

- DATE Tap the day, month and year respectively and set the date using the
and
arrows and tapping to confirm .

- SETUP WIZARD On the SETUP information screen, tap
to start. You can always tap
button to read more about each function.
- FLOORING TYPE Use the
and
arrows to select the flooring type. Tap
to confirm.
Note: ALWAYS use a floor temperature sensor for wooden or similar materials floor constructions!
- CONTROL MODE Use the
and
arrows to select whether to use only the floor sensor or a combination of room and floor sensors. Tap
to confirm.
Note: Only Room and Power regulation options may also be available if the floor sensor is not connected and the Flooring type is Tiles. - FLOOR SENSOR TYPE Use the
and
arrows to select the installed floor sensor type. The measured resistance and corresponding temperature are shown in brackets. Tap
to confirm.
- SYSTEM OUTPUT Use the
and
arrows to select the approximate output of the heating elements. Tap
to confirm.
- FIRST SETUP is completed Now the first thermostat setup is complicated and there are 2 options: view the on-screen symbol definitions or go directly to the home screen.

SYMBOLS DEFINITION
Screen icons definitions can also be found at any time under Settings/Info menu.
HOME SCREEN
All icons on the home screen are clickable, and a pop-up window with information appears.
QUICK ACCESS
The blue touch button can be used for quick access to important functions, returning to the home screen, or for a factory reset.
FACTORY RESET
To perform a factory reset, tap and hold the touch button for 5 seconds. After 5 seconds of countdown, all settings are reset except:
- Operation time (hours)
- Relay ON (hours)
- Relay ON (shifts)

For more information, refer to the User Guide
DEVIreg™ Solo Virtual User Interface. Here you can see for yourself how smart and simple DEVIreg™ Solo is.
Technical specification


Standard Compliance
Electrical safety, Electro-Magnetic Compatibility and Radio aspects for this product is covered by compliance with the following relevant standards:
- EN/IEC 60730-1 (general)
- EN/IEC 60730-2-7 (timers and time switchers)
- EN/IEC 60730-2-9 (thermostat)
Safety instruction
Make sure that the mains power supply to the thermostat is shut off before starting the installation.
Important: If the thermostat is used to control a floor heating element, always use a floor temperature sensor and never set the maximum floor temperature higher than the manufacturer recommends for the specific floor type. The device is limited to a floor temperature of 35 °C due to compliance requirements. If the top floor is made of laminate, parquet or solid wood, the unit must be limited to a maximum floor temperature of 27 °C unless otherwise described.
- Electric heating thermostats should always be installed in accordance with local building codes and electrical regulations. Installation should be carried out by an authorized and/or qualified installer.
- The thermostat must be used in a wall-mounted installation supplied through an all-pole disconnection switch (fuse).
- Do not expose the thermostat to moisture, water, dust, or excessive heat.
- This thermostat can be used by children aged 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge, if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved, by a person responsible for their safety.
- Children should be supervised to ensure that they do not play with the thermostat.
- The device is designed for permanent operation.
Error table
Eco Design Sheet
To comply with ECO design regulations for electric local space heaters 1103/2024 the following table is to be filled in with the specifics of the heating system. Herein the thermostat information for this specific product is prefilled. Please fill any/all blank slots.
Information requirements for electric local space heaters



Control function codes

Warranty
A 5-year product warranty is valid for
thermostats including DEVIreg™ Solo.Should you, against all expectations, experience a problem with your DEVI product, you will find that Danfoss offers DEVIwarranty valid from the date of purchase that was no later than 5 years from production date on the following conditions: During the warranty period Danfoss shall offer a new comparable product or repair the product if the product is found to be faulty by reason of defective design, materials or workmanship. The decision to either repair or replace will be solely at the discretion of Danfoss. The decision to either repair or replace will be solely at the discretion of Danfoss. Danfoss shall not be liable for any consequential or incidental damages including, but not limited to, damages to property or extra utility expenses. No extension of the warranty period following repairs undertaken is granted.The warranty shall be valid only if the WARRANTY CERTIFICATE is completed correctly and in accordance with the instructions, the fault is submitted to the installer or the seller without undue delay and proof of purchase is provided. Please note that the WARRANTY CERTIFICATE must be filled in, stamped and signed by the authorized installer performing the installation (Installation date must be indicated). After the installation is performed, store and keep the WARRANTY CERTIFICATE and purchase documents (invoice, receipt or similar) during the whole warranty period. DEVIwarranty shall not cover any damage caused by incorrect conditions of use, incorrect installation or if installation has been carried out by non-authorized electricians. All work will be invoiced in full if Danfoss is required to inspect or repair faults that have arisen as a result of any of the above. The DEVIwarranty shall not extend to products which have not been paid in full. Danfoss will, at all times, provide a rapid and effective response to all complaints and inquiries from our customers. The warranty explicitly excludes all claims exceeding the above conditions. For full warranty text visit www.devi.com. devi.danfoss.com/en/warranty/
WARRANTY CERTIFICATE
Disposal instruction
This symbol on the product indicates that it may not be disposed of as household waste.It must be handed over to the applicable take-back scheme for the recycling of electrical and electronic equipment.
- Dispose of the product through channels provided for this purpose.
- Comply with all local and currently applicable laws and regulations.
- Danfoss A/S
- Nordborgvej 81
- 6430 Nordborg
- Denmark
Danfoss can accept no responsibility for possible errors in catalogues, brochures andother printed material. Danfoss reserves the right to alter its products without notice.This also applies to products already on order provided that such alterations can bemade without subsequent changes being necessary in specifcations already agreed.All trademarks in this material are property of the respective companies. DEVI and allDEVI logotypes are trademarks of Danfoss A/S. All rights reserved.140R0200 | AN543532381072en-010103Produced by Danfoss © 2026.03
customer services
140F1172DEVIreg™ Solo (White)Room thermostatFloor/Room sensors220 V-240 V~ 50/60 Hz16 A/3680 W @ 230 V5 °C to 35 °CIP21Danfoss Ltd. 22 Wycombe End HP9 1NB, DESIGNED IN DANMARK GB140R0200WWW.DEVI.COM
Troubleshooting
- If the thermostat does not power on after installation, double-check that the electric circuit is re-energized and all pole disconnectors are turned on.
- Ensure all wires are securely connected to the correct terminals as per the wiring diagram. Loose connections can prevent proper operation.
- If the floor heating is not working as expected, verify that the floor sensor is correctly installed and positioned midway between heating cables.
- If the display is blank, check if the small plastic strip on the back of the front display has been removed to activate the battery backup.
- For issues with specific control modes (Room only, Power regulation), ensure your floor construction is concrete with tile flooring, as these modes are only available for that setup.
- If the thermostat is not responding to settings, ensure it is not exposed to direct sunlight or heating appliances, which can interfere with temperature readings.
- If you suspect a fault, refer to the warranty information and contact customer support. Do not attempt to repair the device yourself.
FAQs
What is the DEVIregTM Solo used for?
The DEVIregTM Solo is an energy-efficient programmable indoor thermostat designed for use with electric floor heating systems.
Can I install the thermostat in a bathroom?
You must follow local regulations regarding IP classes. While it cannot be installed in direct wet areas (Zones 0, 1, and 2), it can be installed in other bathroom zones if local regulations permit.
Is a floor sensor always required?
It is always recommended to install a floor sensor. It is MANDATORY for wooden or similar materials floor constructions.
What are the available control modes?
The thermostat offers Floor, Room + Floor, only Room*, and Power regulation* modes. *Note: ‘only Room’ and ‘Power regulation’ modes are available ONLY for concrete floor construction with tiles flooring.
What is Pulse Width Modulation (PWM)?
PWM is a feature that provides an efficient way of controlling your electric floor heating system, optimizing energy usage.
What should I do before connecting the wires?
Always ensure that the electric circuit is de-energized by turning off all pole disconnectors before making any wire connections.
How high should I install the thermostat?
The thermostat should be installed on the wall at an appropriate height, usually 150 cm.
What is included in the box?
The box contents typically include the Front display of the thermostat, Power supply, and a Frame (55×55 mm).
Documents / Resources
![]() | 140F1172 Programmable Timer Thermostat |
References
- devi.danfoss.com/en/warranty/devi.danfoss.com
- devi.comwww.devi.com
- User Manualmanual.tools