DEMA Fusion One User Guide

DEMA logo

DEMA Fusion One

DEMA Fusion One image

Installation and Setup Guide

Fusion One accurately blends proportioned chemical with water for cleaning, sanitizing or `needs. The dispensing system uses a pilot drive water valve designed for easy maintenance. Fusion One is engineered with 1055 approved back flow protect using DEMA’s Air Gap or Action Gap proportioning system.

Warnings

All installations must conform to local plumbing codes and use approved backflow prevention devices. A pressure indicating tee is to be installed with existing faucets according to local plumbing codes in the state of Wisconsin and any other state that requires the use of a pressure indicating tee.

ALWAYS WEAR PROTECTIVE CLOTHING AND EYEWEAR WHEN WORKING WITH CHEMICAL PRODUCTS.

Installation and Servicing

WARNING: INSTALLATION OF DEMA PRODUCTS MUST MEET ALL APPLICABLE PLUMBING CODES AND REGULATIONS ESTABLISHED BY NATIONAL, CITY, COUNTY, PARISH, PROVINCIAL OR OTHER AGENCIES. IT IS POSSIBLE THAT PLUMBING CODES AND REGULATIONS REQUIRE THAT A CERTIFIED INSTALLATION CONTRACTOR OR ENGINEER PERFORM THE PLUMBING INSTALLATION.

  1. Locate where to install the Fusion One dispenser. Keep the following in mind
    a. Mount near or over the mop sink.
    b. Mount so that discharge hoses will be above the water line.
    c. Best access to water hookup.
  2. Remove the Fusion One cover by pressing the plastic tabs on the side of the unit and swing the bottom away from the mounting bracket.DEMA Fusion One fig1
  3. Determine if the water supply connection should be on the right of left hand side of the dispenser.
    a. The entire valve and proportioner assembly can be removed from the mounting bracket (see illustration on this page).
    b. The water supply connection can be moved to either side by removing the plastic, orange retainer clips, the plug and the water connection fitting. Then replace the retainer clips.DEMA Fusion One fig2
  4. Locate the 2 key shaped mounting holes in the back plate. Mount the Fusion One using the 2 mounting screws and anchors that are included in the installation kit; with the aid of the integrated bubble level.
  5. Install the desired metering tip by threading tip into the proportioner chemical pick-up elbow.
  6. Cut the chemical supply tube to the length allows the foot valve to rest on the bottom of the chemical container. Slide the ceramic weight onto the chemical supply tube until it is against the foot valve. This will keep the foot valve at the bottom of the chemical container.
    a. Note: Chemical containers cannot be greater than 6 feet (1.8M) below the Fusion One dispenser.
  7. Cut the outlet tubing to the desired length. When using the system to fill mop buckets, it is recommended to cut the out let tubing so that it is above the intended fill line (water line).
  8. Install the Fusion One cover by positioning the top of the cover near the top of dispenser back plate and push the cover back over the valve assembly until the tab latches on side of the unit.
  9. Connect the water line to the inlet of the Fusion One.
    a. Note: The water pressure must be between 20psi and 95psi. Optimum chemical induction occurs between 30psi – 60psi.
    b. The water inlet options for the Fusion One are:
    1. Garden Hose (female)
    2.  3/8” Brass Compression Fitting (suitable for 3/8” OD soft copper water line)
    3. 3/8” John Guest Push-on Water Fitting (suitable for 3/8” OD soft copper or LDPE tubing)
    4. 3/8” Brass Barb Water Fitting (suitable for 3/8” LDPE tubing)
      c. The Fusion One can be used in conjunction with a pressure indicating tee, P/N 68.6.QD2.DEMA Fusion One fig3
  10. Removal of Button Tab to engage Locking Activation feature (for 4GPM Proportioners).
    Step 1: Remove Fusion One cover (see #2 above).
    Step 2: Break off tab with pliers.

Fusion Cover – Rear View

DEMA Fusion One fig4

Metering Tip Kits

Table 1: Fusion Metering Tips 100.15K (Provided)
 

Metering Tip Color

1 GPM Air Gap Proportioner 4 GPM Air Gap Proportioner
Oz./gal ml/L Ratio : 1 Oz./gal ml/L Ratio : 1
Tan 1.37 10.57 93.65 0.37 2.91 343.19
Orange 1.67 12.91 76.48 0.44 3.45 289.14
Turquoise 1.74 13.44 73.43 0.49 3.83 260.27
Pink 3.45 26.28 37.06 0.92 7.12 139.38
Light Blue 4.47 33.73 28.65 1.10 8.49 116.74
Brown 5.04 37.87 25.41 1.40 10.80 91.62
Red 6.89 51.08 18.58 1.78 13.70 72.01
White 7.43 54.87 17.23 1.90 14.60 67.48
Green 7.46 55.06 17.16 1.98 15.26 64.53
Blue 9.14 66.63 14.01 2.54 19.44 50.45
Yellow 14.07 99.07 9.09 4.29 32.46 29.81
Black 17.36 119.45 7.37 4.53 34.19 28.25
Purple 31.36 196.81 4.08 7.67 56.53 16.69
Gray 34.95 214.51 3.66 8.77 64.15 14.59
No Tip 35.95 219.31 3.56 10.54 76.05 12.15
Table 2: Ultra Lean Metering Tips 100.15KU (Not Provided)
 

Metering Tip Color

1 GPM Air Gap Proportioner 4 GPM Air Gap Proportioner
Oz./gal ml/L Ratio : 1 Oz./gal ml/L Ratio : 1
Copper 0.47 3.70 269.58 0.14 1.10 904.85
Pumpkin 0.75 5.80 171.35 0.22 1.71 585.42
Burgundy 0.87 6.75 147.10 0.25 1.98 503.37
Lime Green 1.07 8.26 120.14 0.31 2.44 408.69
Table 3: Fusion Metering Tips 100.15K (Provided)
 

Metering Tip Color

1 GPM Action Gap Proportioner 4 GPM Action Gap Proportioner
Oz./gal ml/L Ratio : 1 Oz./gal ml/L Ratio : 1
Tan 0.96 7.46 133.12 0.32 2.49 399.99
Orange 1.20 9.30 106.51 0.38 2.97 335.84
Turquoise 1.43 11.01 89.81 0.45 3.50 285.06
Pink 2.26 17.36 56.62 0.79 6.15 161.72
Light Blue 2.87 21.95 44.56 1.01 7.81 127.09
Brown 3.40 25.86 37.68 1.20 9.30 106.48
Red 4.10 31.08 31.18 1.42 10.99 89.99
White 4.67 35.18 27.43 1.67 12.86 76.79
Green 4.85 36.54 26.38 1.79 13.81 71.40
Blue 6.96 51.58 18.39 2.46 18.83 52.10
Yellow 10.27 74.31 12.46 3.79 28.79 33.74
Black 12.90 91.59 9.92 4.86 36.59 26.34
Purple 26.69 172.54 4.80 11.31 81.19 11.32
Gray 30.36 191.72 4.22 13.76 97.10 9.30
No Tip 45.48 262.17 2.81 24.77 162.15 5.17
Table 4: Ultra Lean Metering Tips 100.15KU (Not Provided)
 

Metering Tip Color

1 GPM Action Gap Proportioner 4 GPM Action Gap Proportioner
Oz./gal ml/L Ratio : 1 Oz./gal ml/L Ratio : 1
Copper 0.34 2.67 373.60 0.12 0.94 1060.18
Pumpkin 0.56 4.33 230.23 0.19 1.50 665.14
Burgundy 0.77 6.00 165.66 0.24 1.85 539.29
Lime Green 0.84 6.52 152.39 0.28 2.21 451.24

Replacement Parts: Fusion Unit

DEMA Fusion One fig5

Fusion One units can be connected together using the Fusion Valve Connector (41.186.1). It would replace the Plug Adapter (40.926.1) on one of the units, and the Inlet Adapter Assembly (40.925.1 & 40.925.2) of the other unit. Please use the orange retainer clips (40.854.1), to secure the connector in place. DEMA Fusion One fig6

FUSION REPLACEMENT PARTS
Item

No.

DEMA Part No. QTY DESCRIPTION
1 40.826.1 1 BASE, FUSION HK
2 40.970.1 1 FUSION BUBBLE LEVEL
3 44.116.3 3 #8 HI-LO SCREW X 1″ LONG
4 40.847.2 1 FUSION VALVE ASSEMBLY (SEE PG. #7 FOR PARTS)
5 63.78 4 O-RING-SEAL EPT (7/16″I.D. X 3/8″O.D. X 1/16″ NOM.)
6 40.853.1 1 END PLUG PILOT ACTIVATED VALVE
7 40.854.1 2 RETAINING CLIP PILOT ACTIVATED VALVE
8 40.931.1 1 BOTTOM LEVER, FUSION HK
9 40292.1 1 EXTENSION SPRING
10 40.929.1 1 BUTTON, FUSION HK
11 41.185.1 1 FRONT COVER, FUSION, W/LABELS
12 40.930.1 1 RETENTION LATCH
13 81.20.2 2 #4 X 3/8″ HI LO SCREW
14 61.22.3 1 ACTION GAP PROPORTIONER ASSEMBLY (4GPM)
15 16.30 1 ACTION GAP
16 65.10.2 1 STANDARD COUPLING, GARDEN HOSE THREAD
16 98.55.1 1 EURO COUPLING, BRITISH HOSE THREAD
17 40.852.1 1 WATER INLET FITTING, PILOT ACTIVITED VALVE
18 100.38 1 STRAINER WASHER
19 61.22.3BAG 1 AIR GAP PROPORTIONER ASSEMBLY (4GPM)
20 40.925.1 1 FUSION VALVE INLET ADAPTER W/GHT, ASSEMBLY
20 40.925.2 1 FUSION VALVE INLET ADAPTER W/BRITISH HOSE THREAD,

ASSEMBLY

21 40.926.1 1 FUSION VALVE PLUG ADAPTER, ASSEMBLY
22 77.2.1.06 1 FLOW DISC, PINK, [1.06(GPM) / 4(L/MIN)]

*Not Installed W/Air Gap Models*

22 77.6.2.64 1 FLOW DISC, YELLOW, [2.64(GPM) / 10(L/MIN)]
22 40.570.1 1 FLOW DISC, NATURAL, [4.45(GPM) / 16.85(L/MIN)]
23 89.18.1 1 RETAINER, FLOW DISC
24 41.186.1 – FUSION VALVE CONNECTOR
25 89.30.GAP 1 HOSE HANGER ASSY. FOR GAP MODELS ONLY

Replacement Parts Valve Body

DEMA Fusion One fig7

VALVE REPLACEMENT PARTS
Item No. DEMA Part No. QTY DESCRIPTION
1 40.854.1 2 RETAINING CLIP PILOT ACTIVATED VALVE
2 41.058.1 1 DIAPHRAGM CAP
3 619.21 1 O-RING SEAL EPDM (15/16” X 1/16”)
4 98.26.1 1 1-1/16″ DIAPHRAGM
5 40.824.1 1 VALVE BODY
6 40.849.1 1 BUTTON, PILOT ACTIVATED VALVE
7 640.106 2 O-RING SEAL (3/16″ID X 3/8″OD X 3/32″NOM.)
8 98.39.2 1 RETURN SPRING
9 63.78 1 O-RING-SEAL EPT (7/16″I.D. X 9/16″O.D. X 1/16 NOM.)
10 40.851.1 1 BOTTOM CAP

Specifications

  • Operation Pressure Rating: 20psi – 95psi
  • Safety Pressure Rating: 125psi
  • Water Temperature Rating: 45ºF (7ºC) – 125ºF (50ºC) Max
  • Back Flow Protection – ASSE 1055 (Action Gap & Air Gap)
  • ASME A112.1.2 (Air Gap)

Warranty

Merchandise Returns
No Merchandise Will Be Returned For Credit Without DEMA’S Written Permission. Returned Merchandise Authorization Number Is Required In Advance Of Return.

Product Warranty
DEMA products are warranted against defective material and workmanship under normal use and service for one year from the date of manufacture. This limited warranty does not apply to any products that have a normal life shorter than one year or failure and damage caused by chemicals, corrosion, physical abuse, or misapplication. Rubber and synthetic rubber parts such as “o”-rings, diaphragms, PVC tubing, and gaskets are considered expendable and are not covered under warranty. This warranty is extended only to the original buyer of DEMA products. If products are altered or repaired without prior approval DEMA, this warranty is void.

Defective units or parts should be returned to the factory with transportation prepaid. If inspection shows them to be defective, they will be repaired or replaced without charge, F.O.B. factory. DEMA assumes no liability for damages. Return merchandise authorization number must be granted in advance of return units for repair or replacement (See “Merchandise Returns” above). DEMA Fusion One fig8

Documents / Resources

PDF thumbnailFusion One
User Guide · DEMA, Fusion One, Housekeeping, Chemical, Dispensing System

References

Ask a Question

Use this section to ask about setup, compatibility, troubleshooting, or anything missing from this manual.

Ask a Question

Ask about setup, compatibility, troubleshooting, or anything missing from this manual. Name and email are optional.