The X-Sense XP0H-SN is a standalone combination smoke and carbon monoxide alarm designed to provide reliable 24/7 protection for your home. This device features built-in sensors for both smoke and carbon monoxide, offering a single, compact safety solution. It is certified to UL 217 9th Edition standards, ensuring high performance and safety.

X-Sense XP0H-SN Smoke and Carbon Monoxide Alarm certified to UL 217 9th Edition

Figure 1: X-Sense XP0H-SN device with UL 217 9th Edition certification shown.

2. Hauptmerkmale

Close-up of X-Sense XP0H-SN LCD showing CO level and battery indicator

Figure 2: The informative LCD screen displays critical information clearly.

3. Packungsinhalt

The following items are included in your X-Sense XP0H-SN package:

Contents of the X-Sense XP0H-SN package including the alarm, manual, screws, and anchor plugs

Figure 3: All components included in the X-Sense XP0H-SN product kit.

4. Einrichtung und Installation

The XP0H-SN is a standalone unit and does not require complex wiring. It is designed for easy installation.

  1. Ort wählen: Select a suitable location for the alarm. For optimal smoke detection, install on the ceiling in the center of a room or at least 4 inches (10 cm) from any wall. For carbon monoxide detection, install at least 5 feet (1.5 m) from the floor. Avoid installing near windows, doors, or areas with high humidity or extreme temperatures.
  2. Montieren Sie die Halterung: Use the provided screws and anchor plugs to securely attach the large mounting bracket to the ceiling or wall. The large 5.7-inch (145 mm) bracket is designed to cover existing marks for a neat finish.
  3. Aktivieren Sie den Alarm: Once the mounting bracket is secured, align the alarm with the bracket and twist clockwise to lock it into place. The alarm will automatically activate upon proper installation into the mounting bracket.
Man installing X-Sense XP0H-SN Smoke and Carbon Monoxide Alarm on a ceiling, highlighting the 5.7 inch mounting bracket

Figure 4: Proper installation of the X-Sense XP0H-SN using the large mounting bracket.

5. Bedienungsanleitung

The X-Sense XP0H-SN operates continuously once activated. The LCD screen will display '0 PPM' under normal conditions, indicating no detectable carbon monoxide. The battery life is approximately 10 years.

  1. Testen des Alarms: Press the 'TEST/SILENCE' button located on the front of the alarm. The alarm will emit a loud siren and the LCD will illuminate, indicating proper functionality. This also tests the sensors, electronics, and battery.
  2. Alarm stummschalten: In case of a nuisance alarm (e.g., from cooking smoke), press the 'TEST/SILENCE' button to temporarily silence the alarm. The alarm will automatically reset after a few minutes if the smoke/CO levels return to normal.
  3. Understanding the LCD: The LCD displays real-time carbon monoxide (CO) levels in parts per million (PPM) and a battery life indicator. It remains off during standby to conserve power and avoid disturbance, lighting up only during alarms or when the test button is pressed.

Video 1: Demonstrates how to test the X-Sense smoke alarm using the test button.

6. Verbindung

Bitte beachten Sie: The X-Sense XP0H-SN is a basic standalone unit. It does not support wireless interconnection, does not have Wi-Fi, and cannot be used with a base station. For an interconnected version, please refer to other X-Sense models such as XP0H-WN.

7. Wartung

Regular maintenance ensures the optimal performance and longevity of your alarm.

X-Sense XP0H-SN Smoke and Carbon Monoxide Alarm performing a continuous self-test every 60 seconds

Figure 5: The device performs continuous self-tests every 60 seconds for reliable operation.

8. Fehlerbehebung

If your alarm sounds, follow these steps:

  1. Operate the Test/Silence Button: Press the button to silence the alarm.
  2. Notruf wählen: If the alarm persists or indicates a fire/CO emergency, immediately call your local fire department or 911.
  3. Evacuate and Ventilate: Immediately move outside to fresh air. Do not re-enter the premises until emergency services responders have arrived and confirmed it is safe.
  4. Alarm Reactivates: If the alarm reactivates within a 24-hour period, repeat steps 1-3 and call a qualified appliance technician to investigate for sources of CO from fuel-burning equipment.

9. Spezifikationen

MarkeX-Sense
ModellnummerXP0H-SN
StilStandalone Model (1-Pack)
StromquelleBattery Powered (10-Year Non-Replaceable Lithium Metal Battery)
Technische Daten5.7"T x 5.7"B x 2"H
AlarmtypHörbar
SensortypElektrochemisch, Photoelektrisch
MaterialHitzebeständiges PC-Kunststoffmaterial
Artikelgewicht13.6 Unzen

10. Sicherheitshinweise

WARNUNG: Carbon monoxide cannot be seen or smelled but can kill you. If the alarm sounds:

  1. Betätigen Sie die TEST/SILENCE-Taste.
  2. Rufen Sie den Notdienst (Feuerwehr oder 911).
  3. Immediately move to fresh air - outdoors or by an open door/window.

Deaktivieren Sie die Alarmanlage erst, nachdem das Signal zum Ende der Lebensdauer ertönt ist. Nach Erreichen der maximalen Lebensdauer (10 Jahre) piept das Gerät alle 30 Sekunden zweimal, um anzuzeigen, dass es deaktiviert und ausgetauscht werden muss.

11. Garantie und Support

For detailed warranty information, troubleshooting, and technical support, please refer to the complete user manual included in the package or visit the official X-Sense website. Ensure you keep your user manual for future reference.

Hersteller: X-Sense Electronics., Ltd.

Zugehörige Dokumente - XP0H-SN

Vorview X-Sense Kombi-Rauch- und Kohlenmonoxidmelder – Benutzerhandbuch
Diese Bedienungsanleitung enthält wichtige Informationen zur Bedienung, Installation und den Sicherheitsfunktionen des X-Sense Kombinations-Rauch- und Kohlenmonoxidmelders. Erfahren Sie mehr über den Lieferumfang, die Funktionsweise der Rauch- und CO-Erkennung, die Alarmtöne, die LED-Anzeigen, die technischen Daten und wichtige Sicherheitstipps zum Schutz Ihres Zuhauses und Ihrer Familie.
Vorview X-Sense SC01/SC02 Kombinierter Rauch- und Kohlenmonoxidmelder – Benutzerhandbuch
Ausführliche Bedienungsanleitung für den X-Sense SC01/SC02 Kombi-Rauch- und Kohlenmonoxidmelder. Erfahren Sie mehr über Installation, Bedienung, Sicherheitshinweise und Wartung dieses Geräts mit 10-Jahres-Batterie.
Vorview X-Sense SC01/SC03/SC06/SC07/SC08 Kombinierter Rauch- und Kohlenmonoxidmelder – Benutzerhandbuch
Diese Bedienungsanleitung enthält wichtige Informationen zum X-Sense Kombinations-Rauch- und Kohlenmonoxidmelder (Modelle SC01, SC03, SC06, SC07, SC08). Sie behandelt Produktmerkmale, Installation, Bedienung, Wartung und Fehlerbehebung, um einen effektiven Schutz Ihres Zuhauses vor Rauch- und Kohlenmonoxidgefahren zu gewährleisten.
Vorview X-SENSE SC06 Kombi-Rauch- und CO-Melder – Benutzerhandbuch
Ausführliche Bedienungsanleitung für den X-SENSE SC06 Kombi-Rauch- und Kohlenmonoxidmelder. Erfahren Sie mehr über die duale Detektionstechnologie, die 10-Jahres-Batterie, die Installation, die Bedienung und wichtige Sicherheitshinweise zum Schutz Ihres Zuhauses und Ihrer Familie vor Brand- und Kohlenmonoxidgefahren.
Vorview X-Sense Link+ Pro XP0A-MR Kombi-Rauch- und Kohlenmonoxidmelder – Benutzerhandbuch
Ausführliches Benutzerhandbuch für den X-Sense Link+ Pro XP0A-MR, einen intelligenten Rauch- und Kohlenmonoxidmelder. Erfahren Sie mehr über Einrichtung, Installation, Funktionen, Wartung und Fehlerbehebung für mehr Sicherheit in Ihrem Zuhause.
Vorview X-Sense SC07-MR Link+ Pro Smoke and Carbon Monoxide Alarm User Manual
Get detailed instructions and safety information for the X-Sense SC07-MR Link+ Pro Combination Smoke and Carbon Monoxide Alarm. Covers setup, features, and troubleshooting.