Tektronix MSO22 2-BW-100

Tektronix MSO22 2-BW-100 Mixed Signal Oscilloscope

Bedienungsanleitung

Einführung

This manual provides essential information for the safe and efficient operation of your Tektronix MSO22 2-BW-100 Mixed Signal Oscilloscope. This instrument is designed for precise measurement and analysis of electronic signals, featuring a 100 MHz bandwidth and 2 analog channels.

Zu den Hauptmerkmalen gehören:

Einrichtung und Anschlüsse

Before operating the oscilloscope, ensure it is placed on a stable, level surface with adequate ventilation. Connect the power cord to the instrument and a grounded AC outlet.

Front view of the Tektronix MSO22 2-BW-100 Mixed Signal Oscilloscope

Figure 1: Front panel of the Tektronix MSO22 2-BW-100 Oscilloscope, showing the display, control knobs, buttons, and input connectors (Inputs 1, 2, Aux In, AFG/Aux Out).

Eingangsanschlüsse

Einschalten

Press the power button located on the front panel to turn on the instrument. Allow a few moments for the system to boot up.

Bedienungsanleitung

This section outlines the basic steps for operating the oscilloscope to capture and analyze waveforms.

Basic Waveform Capture

  1. Sonde anschließen: Attach a compensated probe to one of the analog input channels (e.g., Input 1).
  2. Anschluss an den Schaltkreis: Connect the probe tip to the test point in your circuit and the ground clip to the circuit's ground.
  3. Automatische Einstellung: Drücken Sie die Auto-Set button (if available, common on oscilloscopes) to automatically adjust vertical and horizontal settings for a stable display.
  4. Vertikale Skala anpassen: Verwenden Sie die Vertikale Skalierung knob to adjust the volts per division, controlling the amplitude of the waveform on the screen.
  5. Horizontale Skala anpassen: Verwenden Sie die Horizontale Skalierung knob to adjust the seconds per division, controlling the time base of the waveform.
  6. Trigger einstellen: Verwenden Sie die Trigger-Level Drehknopf zum Einstellen der Lautstärketage level at which the oscilloscope captures the waveform, ensuring a stable display.

Messfunktionen

The MSO22 2-BW-100 offers various automated measurement functions. Access these through the on-screen menu system. Common measurements include Peak-to-Peak Voltage, Frequency, Period, and Rise/Fall Time.

Wartung

Durch sachgemäße Wartung werden die Langlebigkeit und Genauigkeit Ihres Oszilloskops gewährleistet.

Reinigung

Kalibrierung

For optimal performance, periodic calibration by qualified service personnel is recommended. Refer to the official Tektronix service manual for calibration procedures and intervals.

Fehlerbehebung

Dieser Abschnitt bietet Lösungen für häufig auftretende Probleme.

If problems persist, contact Tektronix customer support.

Technische Daten

Detailed technical specifications for the Tektronix MSO22 2-BW-100 Mixed Signal Oscilloscope.

BesonderheitSpezifikation
ModellnummerMSO22 2-BW-100
Analoge Eingangskanäle2 Eingänge
Bandbreite100 MHz
Sample Rate (Half Channels)2.5 GS/s
Sample Rate (All Channels)1.25 GS/s
Datensatzlänge10 Mpoints per channel
Vertikale Auflösung8 bits ADC; Up to 16 bits in high-resolution mode
HerstellerTektronix
Datum der ersten Verfügbarkeit17. Juni 2022

Garantie und Support

Tektronix products are designed for reliability and performance. For information regarding product warranty, please refer to the warranty statement included with your purchase or visit the official Tektronix webWebsite.

For technical support, service, or additional documentation, please contact Tektronix customer service or visit their official support portal. Ensure you have your product model number (MSO22 2-BW-100) and serial number ready when contacting support.

Online-Ressourcen: www.tek.com

Zugehörige Dokumente - MSO22 2-BW-100

Vorview Tektronix 2 Series MSO MS022 und MS024 Servicehandbuch
Umfassendes Servicehandbuch für Tektronix 2 Series MSO-Oszilloskope (Modelle MS022 und MS024), das Sicherheit, Funktionsweise, Wartung, Fehlersuche und austauschbare Teile abdeckt.
Vorview Tektronix 2 Series MSO Oscilloscope MSO22 and MSO24 Programmer Manual
This programmer manual provides comprehensive guidance on using programmable interface commands to remotely control the Tektronix 2 Series Mixed Signal Oscilloscopes (MSO22 and MSO24). Learn about command syntax, groups, setup, and advanced features for efficient instrument automation.
Vorview Tektronix 2er-Serie Mixed-Signal-Oszilloskop MSO22, MSO24 – Freigabe- und Sicherheitsanweisungen
Instructions for clearing and sanitizing data on Tektronix 2 Series Mixed Signal Oscilloscopes (MSO22, MSO24) to ensure data security when returning for repair or removing from secure environments. Covers memory device types, declassification terms, and main board removal procedures.
Vorview Tektronix 2 Series MSO Quick Start Manual - Setup and Basic Operation
A quick start guide for the Tektronix 2 Series Mixed Signal Oscilloscope (MSO24, MSO22), covering setup, user interface, and basic operation. Learn about safety precautions, connecting probes, instrument configuration, and fundamental measurement techniques.
Vorview Tektronix 3 Series MDO Mixed Domain Oscilloscope: Printable Help Guide
Comprehensive printable help guide for the Tektronix 3 Series MDO Mixed Domain Oscilloscope (MDO32, MDO34), covering installation, operation, features, and troubleshooting.
Vorview Tektronix Serie 2 MSO24, MSO22 Schnellstart-Handbuch
Dieses Schnellstart-Handbuch von Tektronix bietet eine Einführung in die Mixed-Signal-Oszilloskope der Serie 2 (MSO24, MSO22), einschließlich Sicherheitshinweisen, Bedienung und Konfiguration.