Roca 2H0034000

Roca Aquakit Hotels 510 Duschsäule Bedienungsanleitung

1. Einleitung

The Roca Aquakit Hotels 510 Shower Column is designed to enhance your showering experience with its advanced features. This manual provides essential information for the safe installation, operation, and maintenance of your shower column, ensuring optimal performance and longevity.

2. Sicherheitshinweise

  • Lesen Sie alle Anweisungen sorgfältig durch, bevor Sie mit der Installation oder dem Betrieb beginnen.
  • Vor Beginn jeglicher Installationsarbeiten muss unbedingt die Hauptwasserzufuhr abgestellt werden.
  • Professional installation by a qualified plumber is recommended to ensure proper function and compliance with local codes.
  • Do not use abrasive cleaners, solvents, or harsh chemicals on any part of the shower column, as this may damage the finish.
  • Halten Sie Kleinkinder vom Installationsbereich fern.

3. Packungsinhalt

Vor der Installation prüfen Sie bitte, ob alle Komponenten vorhanden und unbeschädigt sind.

  • Roca Aquakit Hotels 510 Shower Column (White)
  • Overhead shower head
  • Integrated body jets
  • Control knobs and diverter
  • Mounting hardware and seals (specific items may vary)
  • Installationsvorlage (falls enthalten)

4. Einrichtung und Installation

The Roca Aquakit Hotels 510 Shower Column is designed for straightforward installation. Follow these general steps, referring to any specific diagrams or templates provided with your product.

  1. Bereiten Sie den Installationsbereich vor: Ensure the wall surface is clean, dry, and structurally sound. Mark the drilling points using the provided template.
  2. Bohrlöcher: Carefully drill holes at the marked positions, ensuring correct depth and diameter for the mounting hardware.
  3. Wasserversorgung anschließen: Connect the hot and cold water lines to the corresponding inlets on the shower column. Use appropriate sealants and ensure all connections are watertight.
  4. Montieren Sie die Säule: Securely attach the shower column to the wall using the provided mounting brackets and screws. Ensure it is level and firmly fixed.
  5. Install Overhead Shower: Attach the overhead shower head to its connection point.
  6. Auf Dichtheit prüfen: Slowly turn on the main water supply and check all connections for any leaks. Address any leaks immediately.
Roca Aquakit Hotels 510 Shower Column, front view, showing the overhead shower, glass shelf, and control knobs.

This image displays the Roca Aquakit Hotels 510 Shower Column in white. It features a tall, slender design with an overhead shower, a small glass shelf, and multiple control knobs for water flow, temperature, and function selection.

5. Bedienungsanleitung

The Aquakit Hotels 510 Shower Column offers multiple functions for a personalized showering experience.

  • Wasserdurchfluss- und Temperaturregelung: Use the main control knob(s) to adjust the water flow rate and desired temperature.
  • Function Selection Inverter: The integrated inverter allows you to switch between different water outlets. Rotate the inverter to select your preferred function.
  • Sunami Fixed Top Shower: This overhead shower features 4 distinct functions. Rotate the shower head's outer ring or a dedicated control (if present) to cycle through these functions.
  • Rumpfdüsen: Activate the 2 integrated body jets for a targeted massage. These jets are designed for either neck or dorsal massage, depending on your preference and the selected setting.

6. Wartung

Regular cleaning and maintenance will help preserve the appearance and functionality of your shower column.

  • Reinigung: Clean the surface of the shower column with a soft, damp Mit einem Tuch und einer milden, nicht scheuernden Seife reinigen. Gründlich mit klarem Wasser abspülen und mit einem weichen Tuch trocknen, um Wasserflecken zu vermeiden.
  • Vermeiden Sie scharfe Reinigungsmittel: Do not use abrasive sponges, scouring pads, or cleaners containing ammonia, bleach, or alcohol, as these can damage the finish.
  • Düsenreinigung: Periodically clean the nozzles of the overhead shower and body jets to remove any mineral buildup. Many modern shower heads feature flexible silicone nozzles that can be easily wiped clean.
  • Verbindungen prüfen: Periodically inspect all water connections for any signs of leaks or corrosion. Tighten connections if necessary.

7. Fehlerbehebung

If you encounter issues with your shower column, refer to the following common problems and solutions:

ProblemMögliche UrsacheLösung
Niedriger WasserdruckPartially closed shut-off valves; mineral buildup in nozzles; kinked supply line.Ensure all water supply valves are fully open. Clean shower head and jet nozzles. Check supply lines for obstructions.
Leckagen aus VerbindungenLoose connections; worn seals or O-rings.Carefully tighten all connections. If leaks persist, replace seals or O-rings.
Uneinheitliche WassertemperaturImproper hot/cold water supply connection; issue with water heater.Verify hot and cold water lines are correctly connected. Consult a plumber if the issue persists, as it may relate to your water heater.
Diverter Not Switching FunctionsMineral buildup; internal mechanism issue.Attempt to gently work the diverter to dislodge any buildup. If unresponsive, professional service may be required.

8. Spezifikationen

MarkeRoca
Modellnummer2H0034000
Technische Daten9.45 x 3.35 x 40.16 Zoll (24 x 8.5 x 102 cm)
Artikelgewicht16.5 Pfund (7.5 Kilogramm)
FarbeWeiß
BesonderheitEinfach zu installieren
HerstellerRoca

9. Garantie und Support

Roca products are manufactured to high-quality standards and are backed by a manufacturer's warranty. For specific warranty terms and conditions, please refer to the warranty card included with your purchase or visit the official Roca webWebsite.

For technical assistance, spare parts, or any other support inquiries, please contact Roca customer service. Keep your purchase receipt as proof of purchase for any warranty claims.

Roca Customer Service: Please refer to the contact information provided on the Roca official webWebsite oder Ihre Produktverpackung.

Zugehörige Dokumente - 2H0034000

Vorview Columna de Ducha Termostática Roca T-Plus Victoria – Cromado
Entdecken Sie die Duschsäule Roca T-Plus aus der Victoria-Sammlung. Mit ø245-mm-Rotor, 3-fach verstellbar, flexibel, 1.7 m breit. Ideal für moderne und klassische Bäder.
Vorview Roca Legacy Connect A5A9E81 Duschsystem Installationsanleitung
Ausführliche Installationsanleitung für das Duschsystem Roca Legacy Connect A5A9E81. Enthält Schritt-für-Schritt-Anweisungen, eine Teileliste, technische Daten und Reinigungshinweise.
Vorview Roca MULTICLIN ADVANCE RF SF Bidetsitz Benutzerhandbuch
Dieses Benutzerhandbuch enthält umfassende Anweisungen für den Roca MULTICLIN ADVANCE RF SF Bidet-Sitz und behandelt Installation, Bedienung, Sicherheitsvorkehrungen, Wartung und Fehlerbehebung. Erfahren Sie, wie Sie die erweiterten Funktionen für mehr Hygiene und Komfort nutzen.
Vorview Roca IN-WASH INSIGNIA 2.0 Smart-Toilette Benutzerhandbuch
Umfassendes Benutzerhandbuch für die intelligente Toilette Roca IN-WASH INSIGNIA 2.0 mit Informationen zu Installation, Betrieb, Wartung, Sicherheitsvorkehrungen und Fehlerbehebung.
Vorview Roca Debba Unik 500 mm Kompakt-Unterschrank mit zwei Schubladen und Basin - Glänzend Weiß
Entdecken Sie den kompakten Waschtischunterschrank Roca Debba Unik, einen stilvollen und platzsparenden Waschtisch mit zwei Schubladen und einer quadratischen Ablagefläche.asinund einer glänzend weißen Oberfläche. Zur Ausstattung gehören eine Wandmontage und kompatibles Zubehör. Referenznummer: A855904806.