Empire R2890

Empire R2890 Furnace Pilot Burner Instruction Manual

Originalteil vom Originalausrüster (OEM)

1. Einleitung

This manual provides essential information for the proper installation, operation, and maintenance of the Empire R2890 Furnace Pilot Burner. This component is a genuine OEM replacement part designed specifically for Empire DV210 and DV215 furnace models. It is intended for use with Propane (LP) gas only.

For optimal performance and safety, please read these instructions thoroughly before proceeding with any installation or service.

2. Wichtige Sicherheitshinweise

WARNUNG: Unsachgemäße Installation, Einstellung, Änderung, Service oder Wartung kann zu Sachschäden, Verletzungen oder Tod führen. Lesen Sie die Installations-, Betriebs- und Wartungsanweisungen sorgfältig durch, bevor Sie dieses Gerät installieren oder warten.

  • Always disconnect the electrical power and turn off the gas supply to the furnace before attempting any service or installation.
  • Installation und Wartung müssen von einem qualifizierten Installateur, einer Serviceagentur oder einem Gaslieferanten durchgeführt werden.
  • This pilot burner is designed for Propane (LP) gas only. Do not attempt to use it with natural gas or any other fuel type.
  • Ensure all gas connections are properly sealed and tested for leaks after installation.
  • Keep the area around the furnace clear and free from combustible materials, gasoline, and other flammable vapors and liquids.

3. Produktüberschreitungview

The Empire R2890 Pilot Burner is a critical component in your furnace's ignition system. It provides a small, continuous flame that ignites the main burner when heat is called for. This specific model is an OEM replacement, ensuring compatibility and reliable performance with Empire DV210 and DV215 furnaces.

Empire R2890 Furnace Pilot Burner

Abbildung 1: Empire R2890 Furnace Pilot Burner. This image displays the metallic pilot burner assembly, featuring a brass gas inlet, a mounting bracket, and the pilot flame head with a thermocouple connection point.

4. Installationsanweisungen

Professional installation by a qualified technician is strongly recommended for this component.

  1. Vorbereitung: Ensure the furnace's gas supply is turned off and electrical power is disconnected at the circuit breaker or fuse box. Allow the furnace to cool completely if it has been in operation.
  2. Zugang: Carefully remove the furnace access panels to expose the pilot burner assembly. Refer to your specific furnace model's manual for detailed access instructions.
  3. Disconnect Old Pilot Burner:
    • Disconnect the thermocouple and pilot gas line from the existing pilot burner.
    • Unscrew or unclip any mounting hardware securing the old pilot burner in place.
    • Carefully remove the old pilot burner assembly.
  4. Install New Pilot Burner:
    • Position the new Empire R2890 Pilot Burner in the same location as the old unit.
    • Secure it using the appropriate mounting hardware. Ensure it is firmly in place and correctly oriented.
    • Connect the pilot gas line to the new pilot burner. Use a suitable pipe sealant on threaded connections if required by local codes, ensuring it is gas-rated.
    • Connect the thermocouple to the designated port on the pilot burner. Ensure a snug, secure connection.
  5. Dichtheitsprüfung: After all connections are made, slowly turn on the gas supply. Apply a leak detection solution (e.g., soapy water) to all gas connections. Bubbles indicate a leak. If a leak is detected, turn off the gas supply immediately, tighten the connection, and re-test. Do not proceed until all leaks are eliminated.
  6. Stromversorgung wiederherstellen und testen: Restore electrical power to the furnace. Follow the furnace manufacturer's instructions for lighting the pilot and testing the main burner operation.

5. Bedienung

The R2890 Pilot Burner operates as part of a standing pilot ignition system. Once the pilot light is manually lit (or automatically if your furnace has an auto-ignition feature for the pilot), the flame heats the thermocouple. The thermocouple generates a small electrical current, which signals the gas valve to remain open, allowing gas to flow to the pilot burner. When the thermostat calls for heat, the main gas valve opens, and the pilot flame ignites the main burners.

If the pilot flame goes out, the thermocouple cools, stopping the electrical current and causing the gas valve to close, thus shutting off the gas supply for safety.

6. Wartung

Regular inspection and maintenance of the pilot burner are crucial for safe and efficient furnace operation. It is recommended to have your furnace, including the pilot burner, inspected annually by a qualified technician.

  • Sichtprüfung: Periodically check the pilot flame. It should be a strong, steady blue flame, enveloping the tip of the thermocouple. A weak, yellow, or flickering flame may indicate a problem.
  • Reinigung: Over time, dust and debris can accumulate around the pilot burner orifice, affecting the flame. With the gas and electrical supply disconnected, carefully clean the pilot burner area using a soft brush or compressed air. Do not use sharp objects to clean the orifice, as this can damage it.
  • Thermocouple Check: Ensure the thermocouple is securely seated and its tip is properly positioned within the pilot flame. A loose or improperly positioned thermocouple can cause the pilot to go out.

7. Fehlerbehebung

If you experience issues with your pilot burner, consider the following common problems. Always ensure gas and electrical supplies are off before inspecting components.

ProblemMögliche UrsacheLösung
Pilot light won't stay lit
  • Fehlerhaftes Thermoelement
  • Pilot flame not heating thermocouple
  • Schwache Zündflamme
  • Entwürfe
  • Thermoelement ersetzen
  • Adjust pilot flame position
  • Clean pilot orifice
  • Check for and eliminate drafts
Pilot light is weak or yellow
  • Partially clogged pilot orifice
  • Niedriger Gasdruck
  • Clean pilot orifice
  • Contact gas supplier or qualified technician to check gas pressure
No pilot flame
  • Keine Gasversorgung
  • Clogged pilot orifice
  • Gasventil defekt
  • Check gas supply to furnace
  • Clean pilot orifice
  • Contact qualified technician for gas valve inspection

If troubleshooting steps do not resolve the issue, contact a qualified HVAC technician for further assistance.

8. Spezifikationen

  • Modell: R2890
  • Marke: Reich
  • Kraftstoffart: Propane (LP) Only
  • Kompatibilität: Empire DV210, DV215 Furnace Models
  • Teiletyp: Genuine Original Equipment Manufacturer (OEM) Replacement Part
  • Artikelgewicht: Ungefähr 2.71 Unzen
  • Paketabmessungen: Ungefähr 2 x 1 x 0.4 Zoll

9. Garantie und Support

For specific warranty information regarding your Empire R2890 Pilot Burner, please refer to the documentation provided with your original furnace or contact Empire customer support directly. As an OEM part, it typically falls under the warranty terms of the original appliance or a limited parts warranty.

For technical support or service inquiries, please contact a qualified HVAC professional or the Empire manufacturer's customer service department.

Zugehörige Dokumente - R2890

Vorview EMPIRE DV-35-4SG Direct Vent Wall Furnace Owner's Manual & Installation Guide
Official owner's manual and installation guide for the EMPIRE DV-35-4SG and DV-25-5SG Direct Vent Wall Furnace by Empire Comfort Systems Inc. Covers safety, installation, operation, maintenance, and troubleshooting.
Vorview Empire DV20E-6 DV40E-6 Fan Type Direct-Vent Wall Furnace Installation and Owner's Manual
Installation and owner's manual for the Empire DV20E-6 and DV40E-6 fan type direct-vent wall furnace. Includes safety information, installation instructions, specifications, gas supply details, and conversion procedures.
Vorview Installations- und Bedienungsanleitung für den Direct-Vent-Wandofen der Serie Empire DVC35
Umfassende Installationsanweisungen und Bedienungsanleitung für die Direktabzugs-Wandöfen der EMPIRE DVC35-Serie. Behandelt Sicherheit, Installation, Betrieb und Wartung für Modelle wie DVC35SPPXLP-1 und DVC35IPXNAT-1.
Vorview Empire Direct-Vent Wall Furnace Installation Instructions and Owner's Manual
Comprehensive guide for installing, operating, and maintaining Empire's DV210 and DV215 series Direct-Vent Wall Furnaces. Covers safety precautions, gas supply, clearances, lighting, maintenance, troubleshooting, and warranty information.
Vorview EMPIRE SR-18T-4, SR-10T-4, SR-30T-4 Raumheizgerät ohne Entlüftung: Installationsanleitung und Bedienungsanleitung
Umfassende Installationsanleitung und Bedienungsanleitung für die offenen Raumheizgeräte EMPIRE SR-18T-4, SR-10T-4 und SR-30T-4. Behandelt Sicherheitswarnungen, Spezifikationen, Gasversorgung, Installationsverfahren, Betrieb, Wartung, Fehlerbehebung und Ersatzteillisten.
Vorview Installationsanleitung für das Empire DVCTL60 Liner-Set | Empire Comfort Systems
Schritt-für-Schritt-Anleitung zur Installation des Empire DVCTL60 Gaskamin-Einsatzsets (Modell DVP60TLKR). Enthält den Kartoninhalt, benötigte Werkzeuge, Aus- und Einbauanleitung sowie eine Teileliste.