Dazhi BD08 Scent Diffuser

Cautions & Safety Instructions
Avoid casualties and property loss. Please always adhere to the following safety precautions.
- Do not use an unsafe plug or power.
- Do not install the device where children can reach it.
- Do not install the device in locations that cannot bear its weight and are prone to falling or collapsing.
- Do not tilt the device.
- Keep the device away from fire and heat sources. Do not store flammable or explosive materials around the device.
- Except for the atomizer, the housing material is not resistant to corrosion.
- Do not use the device in high-temperature or wet environments.
- Do not operate the device with inflammable, explosive, corrosive, or other hazardous solvents.
- Ensure the stability and firmness of the installation area.
- Install the device in a well-ventilated and adequate space.
- Do not block the sprayer by hand or other obstructions while the device is operating.
- Do not spill water or conductive, corrosive liquids on the surface or inside of the device.
- Cut off the power in extreme weather environments.
Product Specifications

| Model NO. | BD08 |
| Capacity | 400ml |
| Coverage | 2000 sq.ft |
| Size | 202 x 158 x 75mm |
Accessories Instruction

How to Use the Equipment

- Step 1: Press the top button to open the diffuser.
- Step 2: Take out the empty essential oil bottle.
- Step 3: Rotate the cap of the essential oil bottle and add your preferred essential oil.
- Step 4 (Alternative Power Options):
- Install 3pcs D-size batteries or plug in a Type-C cable (for the 5V 2A version).
- Or connect the DC 12V adapter (for the DC 12V version).

- Step 5: Configure the program modes to start using the diffuser.
Operation Panel Introduction

- MODE: Long-press the MODE button for 5 seconds to restore factory default settings (Default: 60s run, 60s pause, 10-hour timer).
- SET: Access and adjust settings for time, week, mist output, etc. Long-press for 5 seconds to lock or unlock the keypad.
- UP: Adjust settings upward (time, date, week, mist density, etc.).
- DOWN: Adjust settings downward (time, date, week, mist density, etc.).
- Status Indicator Lights:
- Green light flashes: The device is actively diffusing.
- Green light stays constant: The device is currently paused.
- Oil Level Indicator: The battery-shaped symbol on the right side of the screen shows the essential oil capacity level (5 levels total).
System Time Setting
- Power on the machine to display the main time interface.
- Press SET once; the hour value will flash. Press UP/DOWN to adjust the hour.
- Press SET a second time to save the hour. The minute value will flash; press UP/DOWN to adjust the minutes.
- Press SET a third time to save the minutes. The weekday indicator will flash; press UP/DOWN to select the current weekday.
- Press SET a fourth time to complete the system time setup.
Programming Five Custom Schedules
The device has a built-in memory function and will preserve all configured parameters even when powered off.
- Press MODE once to edit the start time of the first schedule block (shows Event ON 1 on the screen).
- Press SET and use UP/DOWN to set the start hour.
- Press SET again and use UP/DOWN to set the start minute.
- Press SET a third time; the day indicators will flash. Press DOWN to cycle through the days, and press UP to select/deselect a day (selected days display a “▲” symbol beneath them).
- Press MODE to save the start time settings and proceed to the stop time setup (shows Event OFF 1).
- Press SET and use UP/DOWN to set the stop hour.
- Press SET again and use UP/DOWN to set the stop minute.
- Press MODE to save the stop time. The screen will display Event WORK 1.
- Press UP/DOWN to adjust the active mist duration (adjustable from 0 to 300 seconds; short presses increase or decrease by 5-second intervals).
- Press MODE to save the mist duration. The screen will display Event PAUSE 1.
- Press UP/DOWN to adjust the pause cycle duration (adjustable from 0 to 300 seconds; short presses increase or decrease by 5-second intervals).
- Press MODE to finalize the first program block. The screen will advance to the next schedule profile (Event ON 2). Repeat the steps above to configure additional programs.
Compliance & Certifications
Made in China

FCC WARNINGThis device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
To maintain compliance with FCC’s RF Exposure guidelines, this equipment should be installed and operated with a minimum 20cm distance between the radiator and your body: Use only the supplied antenna.
Troubleshooting
- If the device does not start as expected: Use the MODE button (long-press for 5 seconds) to restore factory default settings (Default: 60s run, 60s pause, 10-hour timer), then reconfigure your desired program.
- If the schedule appears incorrect after power changes: Confirm that the device’s built-in memory function preserves configured parameters even when powered off.
- If you cannot tell whether it is running: Check the status indicator lights: green flashing means actively diffusing; green constant means paused.
Documents / Resources
![]() | BD08 Scent Diffuser |
References
- User Manualmanual.tools