DANISENSE logoDL2000IDDANISENSE DL2000ID Sensors Transducers DigiKey Sensors Transducers DigiKey
User ManualDANISENSE DL2000ID Sensors Transducers DigiKey - Symbols

Features

1 ppm linearity
6 ppm offset
Current output
Fluxgate, closed loop compensated technology with fixed excitation frequency and second harmonic zero flux detection for best in class accuracy and stability
Industry standard DSUB 9 pin connection
Green diode for normal operation indication
Full aluminum body for superior EMI shielding and extended operating temperature range
Large aperture ∅68mm for cables and bus bars

Applications:

MPS for particles accelerators
Gradient amplifiers for MRI devices
Stable power supplies
Precision drives
Batteries testing and evaluation systems
Power measurement and power analysis
Current calibration purposes

Specification highlights Symbol Unit Min Max
Nominal primary AC current IPN AC Arms 2000
Nominal primary DC current IPN DC A -3000 3000
Measuring range ÎPM A -3000 3000
Primary / secondary ratio n1 : n2 1: 1500 1: 1500
Linearity error ƐL ppm -1 1
Offset current (including earth field) IOE ppm -6 6
DC-10Hz Overall accuracy @25°C  (=  ƐL + IOE ) accƐ ppm -7 7
AC Maximum gain error 10Hz to 2kHz ƐG % ±0.01
Operating temperature range Ta °C -40 65
Power supply voltages Uc V ±14.25 ±15.75

Electrical specifications at Ta=23°C, supply voltage = ± 15V unless otherwise stated

Parameter Symbol Unit Min Typ. Max Comment
Nominal primary AC current IPN AC Arms 2000 Refer to fig. 1 & 2 for derating
Nominal primary DC current IPN DC A -3000 3000 Refer to fig. 1 for derating
Measuring range IPM A -3000 3000 Refer to fig. 1 & 2 for derating
Overload capacity ÎOL kA 10 Non-measured, 100ms
Nominal secondary current ISN mA -2000 2000 At norrinal primary DC current
Primary / secondary ratio 1:1500 1:1500
Measuring resistance RM Ω 0 3 Refer to fig. 1 for details
Linearity error ƐL ppm
µA
-1
-2
1
2
ppm refers to nominal current
µA refers to secondary current
Offset current IOE ppm
µA
-6
-12
6
12
ppm refers to nominal current
µA refers to secondary current
DC-10Hz Overall accuracy @25°C (= EL + bE ) accƐ ppm -7 7 ppm refers to nominal DC current
Offset temperature coefficient TCIOE ppm/K
µA/K
-0.1
-02
0.1
0.2
ppm refers to nominal current
µA refers to secondary current
Bandwidth f(-3dB) kHz 300 Small signal, graphs figure 3
Amplitude error 10Hz —2kHz
2kHz -10kHz
10kHz- 100kHz
ƐG % 0.01%
1.50%
3.00%
% refers to nominal current
Phase shift 10Hz —2kHz
2kHz -10kHz
10kHz- 100kHz
θ ° 0.04°
0.5°
Response time to a step current Intg tr @ 90% µs 1 di/dt = 100A/µs
Noise 0 – 100Hz
0 – 1kHz
0 – 10kHz 0 – 100kHz
noise ppm rms 0.02
0.10
1.20
3.50
Measured on secondary current
Fluxgate excitation frequency fExc kHz 15.63
Induced rms voltage on primary conductor µV rms 5
Power supply voltages Uc v ±14.25 ±15.75
Positive current consumption Ips mA 160 170 185 Add Is (if Is is positive)
Negative current consumption Ins mA 150 160 170 Add Is (if Is is negative)
Operating temperature range Ta °c -40 65
Stability
Offset stability over time ppm/month
µA/month
-0.1
-02
0.1
0.2
ppm refers to nominal current
µA refers to secondary current
Offset change with vertical external magnetic field µA /mT 0.2 0.8 (perpendicular to bus bar)
µA refers to secondary current
Offset change with horizontal external magnetic field µA /mT 0.8 2 (parallel to bus bar)
µA refers to secondary current
Offset change with power supply voltage changes µA /V 0.004 0.04 µA refers to secondary current
Offset change with absolute power supply voltages tracking µA /V 0.012 0.04 µA refers to secondary current

Measurement resistor RM and ambient temperature derating (Fig. 1)
Maximum measurement resistor vs. ambient temperaturesDANISENSE DL2000ID Sensors Transducers DigiKey - MeasurementFrequency and ambient temperature derating (Fig. 2)
Maximum primary current ArmsDANISENSE DL2000ID Sensors Transducers DigiKey - Measurement 1Frequency characteristics (Fig. 3)
Amplitude / PhaseDANISENSE DL2000ID Sensors Transducers DigiKey - Measurement 2

Isolation specifications

Parameter  Unit  Value 
Clearance mm 22
Creepage distance mm 22
Comparative tracking index (CTI) V > 600
Rms voltage for AC isolation test, 50/60 Hz, 1 min
– Between primary and (secondary and shield)
– Between secondary and shield
kV 14.4
0.2
Impulse withstand voltage (1.2/50µs) kV 26.3
Rated rms isolation voltage reinforced isolation, overvoltage category III, Pollution degree 2 according to
– IEC 61010-1
– EN50780
V 1500
1500

Absolute maximum ratings

Parameter  Unit  Max  Comment 
Primary kA 10 Maximum 100ms
Power supply V ±16.5

Environmental and mechanical characteristics

Parameter  Unit  Min  Typ  Max  Comment 
Ambient operating temperature
range
°C -40 65
Storage temperature range °C -40 65
Relative humidity % 20 80 Non-condensing
Mass kg 6.5
Connections Power supplies: D-SUB 9 pins male
Standards EN 61326-1 EMC
EN 61010-1:2010 Safety

Advanced Sensor Protection Circuits “ASPC”
Developed to protect the current transducer from typical fault conditions:

  • Unit is un-powered and secondary circuit is open or closed
  • Unit is powered and secondary circuit is open or interrupted

Both DC and AC primary current up to 100% of nominal value can be applied to the current transducers in the above situations without damage to the electronics.
Please notice that the sensor core can be magnetized in all above cases, leading to a small change in output off- set current (less than 10ppm)
Status pins
When transducer is operating in normal condition, the status pins (3 and 8) are shorted.
Status pins properties: – forward direction pin 8 to pin 3, maximum forward current 10mA
– maximum forward voltage 60V, maximum reverse voltage 5V

Accessories

  • 4-channel power supplies unit for connection up to 4xDCCT : DSSIU-4
  • 6-channel power supplies unit for connection up to 6xDCCT : DSSIU-6
  • Transducer cables in 5 lengths (2m – 5m – 10m – 15m – 20m): DSUB2 – DSUB5 – DSUB10 – DSUB15 DSUB20
  • Transducer cable 3m for connection to end-user’s power supply:
    Transducer cable for lab PS (with access to current output via Ø4 banana jacks)

Please visit Danisense homepage for relevant datasheetsDANISENSE DL2000ID Sensors Transducers DigiKey - Measurement 3Positive current direction
Is identified by an arrow on the transducer body

Mounting instructions

• Base plate mounting 4 holes Ø5.5 x 11
4 x M5 steel screws  / 6N.m
• Bottom direct mounting (after unscrewing the base plate) 6 holes Ø4.2 x 7
6 x M4 steel screw  / 4N.m

Declaration of Conformity

Danisense A/S
Malervej 10
DK-2630 Taastrup
Denmark
Declares that under our sole responsibility that this product is in conformity with the provisions of the following EC Directives, including all amendments, and with national legislation implementing these directives:
Directive 2014/30/EU
Directive 2014/35/EU
And that the following harmonized standards have been applied
EN 61010-1 (Third Edition):2010, EN 61010-1:2010/A1:2019
EN 61010-2-030:2021/A11:2021
EN 61326-1:2013
All DANISENSE products are manufactured in accordance with RoHS directive 2011/65/EU. Annex II of the RoHS directive was amended by directive 2015/863 in force since 2015, expanding the list of 6 restricted substances (Lead, Hexavalent Chromium, PBB, PBDE and Cadmium)
Danisense follows the provision in EN 63000:2018

Place
Taastrup, DenmarkDANISENSE DL2000ID Sensors Transducers DigiKey - SignatureHenrik Elbæk
Date: 2022-03-15
2022-11-24
Precision – Innovation
www.danisense.com