Installation of BasicRail

Installation of BasicRail

Danfoss VICTA302 Basic Rail - Fig 1Fig. 1: Attach the selfadhesive Basic perimeter insulation tape on the wall. ¹Danfoss VICTA302 Basic Rail - Fig 2Fig. 2: Score lightly Basic perimeter insulation 3 cm from below, at inside corners on wall side, at outside corners on room side.Danfoss VICTA302 Basic Rail - Fig 3Fig. 3: Begin laying Basic insulation overlap panels with the flap against the wall.Danfoss VICTA302 Basic Rail - Fig 4Fig. 4: Care should be taken when laying the overlapping panels. Tape butt joints and tape lap joints when using liquid screed.Danfoss VICTA302 Basic Rail - Fig 5Fig. 5: Attach connection tape of Basic perimeter insulation avoiding tension and tears in the corners.Danfoss VICTA302 Basic Rail - Fig 6Fig. 6: Position BasicRails according to lay-out. Use pipe cutter to shorten the rail to required length.Danfoss VICTA302 Basic Rail - Fig 7Fig. 7: Install pipe in wide curve and tension free as illustrated and according to lay-out.Danfoss VICTA302 Basic Rail - Fig 8Fig. 8: Fix flow and returns every 2 m with clips. Maximum distance from pipe bend and clip is 25 cm.Danfoss VICTA302 Basic Rail - Fig 9Fig. 9: Only use connectors on straight sections of pipe and not bends.Danfoss VICTA302 Basic Rail - Fig 10Fig. 10: Install pipe in movement joints using protective sleeve.

¹ If additional insulation is > 5 cm attach Basic perimeter insulation on top of additional insulation.

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.

Danfoss logoDanfoss A/S
Heating Solutions
Haarupvaenget 11
8600 Silkeborg
Denmark
Phone:+45 7488 8000
Fax: +45 7488 8100
Email: ComfortControlsInternet@danfoss.com
www.heating.danfoss.com
VICTA302
Produced by Danfoss Heating Solutions © 11/2010

Documents / Resources

PDF thumbnailVICTA302 Basic Rail
Installation Guide · VICTA302 Basic Rail, VICTA302, Basic Rail, Rail

Ask a Question

Use this section to ask about setup, compatibility, troubleshooting, or anything missing from this manual.

Ask a Question

Ask about setup, compatibility, troubleshooting, or anything missing from this manual. Name and email are optional.