Danfoss LogoVickers LogoVane Type Triple Pump
Owner’s Manual

Vickers Vane Type Triple Pump

10. SAE rated capacity (V10 cover end cartridge)

USgpm Rotor V ane Kit
(12 vanes)
Ring Pin (V10S) Pin (V10F/V10P) Bolt (V10S) Bolt (V10F) Bolt (V10P) Cartridge  Kit
1 317681 923499 317674 2456 2456 11156 295344 295344 923471
2 317675 923470
3 317676 923496
4 351247 923500 317677 16662 16662 1278 432511 432511 923469
5 317678 923468
6 357286 923501 355641 179341 179341 432509 295346 295346 923497
7 331813 923498

9. V10 port connection

Code V10S Cover V1 0F Cover V10 P Cover
P 372863 379543
R 372864
S 372865
Y 377829
T            372851
K 388262

Danfoss Vickers Vane Type Triple Pump - Figure 1

Pressure setting

V10P/V10F (Omit for V10S)

Code Pressure setting V10P/V10F QUICK MILL 05010 A EVO Monza Evo Deluxe Espresso Machine - Icon 55 V10P Spring Danfoss Vickers Vane Type Triple Pump - Icon 5 V10F control valve S/A
A 250 psi 252886 229613
B 500 psi 2280 233018
C 750 psi 232794
D 1000 psi 2282 232795
E 1250 psi
232796
F 1500 psi 2281 232797
G 1750 psi 232798
H 2000 psi 232799
J 2250 psi 233019
K 2500 psi 233020

Danfoss Vickers Vane Type Triple Pump - Figure 2

SAE rated capacity

(**25 VQ center cartridge)

VOX ELECTRONICS UHD 50ADW D1B 4K Smart TV - icon 6 USgpm VOX ELECTRONICS UHD 50ADW D1B 4K Smart TV - icon 6 Ring VOX ELECTRONICS UHD 50ADW D1B 4K Smart TV - icon 6 Inlet Plate VOX ELECTRONICS UHD 50ADW D1B 4K Smart TV - icon 6 Rotor VOX ELECTRONICS UHD 50ADW D1B 4K Smart TV - icon 6 Vane Kit VOX ELECTRONICS UHD 50ADW D1B 4K Smart TV - icon 6 F3 Cart. Kit
12 326984 419080 270597 922710 581851
14 326985 581852
17 326986 581853
19 326987 581854
21 326988 581855

slide bar Included in 35** VQ shaft end cartridge kit.
VOX ELECTRONICS UHD 50ADW D1B 4K Smart TV - icon 6 Included in **25 VQ center cartridge kit.
POWERADD T18 Wireless Earbuds - icon 2 Included in V10 cover end cartridge kit.
UP Included in seal kit 920170. (Kit contains F3 componemts & both shaft seals.)
Danfoss Vickers Vane Type Triple Pump - Icon 1 Included in flex side plate kit; bronze face of plate must be installed toward the rotor. Kit also contains four seal packs.
Danfoss Vickers Vane Type Triple Pump - Icon 2 Assemble seal with spring loaded sealing member towards bearing. Seals to be completely wetted with oil prior to assembly.
Danfoss Vickers Vane Type Triple Pump - Icon 3 Install 419674 & 419673 sealing ring into body, then install cartridge kit.

Danfoss Vickers Vane Type Triple Pump - Figure 3

6. SAE rated capacity (35**VQ shaft end cartridge)

slide bar USgpm slide bar Ring slide bar F3 Cart. Kit
21 394961 421582
25 319396 421583
30 319397 421584
35 319398 421585
38 319399 421586

7. Port connections

Connection Type Danfoss Vickers Vane Type Triple Pump - Icon 4 Body Kit Inlet Cover Rear Mounting Cover
A – 4 Bolt Flange (Inch) 02–136919 230189 581863
AM – 4 Bolt Flange (Metric) 02–136920 995239 995240

Danfoss Vickers Vane Type Triple Pump - Icon 4 NOTE: Body kit includes body, ball, and plug. (Ball and plug not shown)

Model Code

Danfoss Vickers Vane Type Triple Pump - Figure 4

  1. Special seals
    F3 – Vition ”O”Rings and shaft seals
  2. Pump series designation
    35**VQ – Shaft end pump
    **25VQ – Center pump
  3. Body mounting flange
    S – SAE mounting per J –744 101 –2
  4. Pump series designation
    V10 cover end pump
  5. V10 pump cover options
    S – Standard cover
    F – Flow control and relief cover
    P – Priority valve and relief cover
  6. SAE rated capacity (VQ shaft – end cartridge)
    Code
    21 – 21 USgpm
    25 – 25 USgpm
    30 – 30 USgpm
    35 – 35 USgpm
    38 – 38 USgpm
  7. VQ port connections (inlet & outlet #1 & #2)
    A – 4 bolt flange (inch threads)
    AM – 4 bolt flange (metric threads)
  8. Rated capacity (VQ center cartridge)
    Code
    12 – 12 USgpm
    14 – 14 USgpm
    17 – 17 USgpm
    19 – 19 USgpm
    21 – 21 USgpm
  9. V10 port connections
    V10S standard covers and outlet # 3
    Code
    S – .750 –16 Str. thd.
    P –½ ” – NPT thd.
    Y – .875 –14 Str. thd.
    R – 1.062 –12 Str. thd.
    V10F flow/relief control cover
    Code Outlet # 3 Tank port
    T – .750 –16 Str. thd .750 –16 Str. thd.
    P –  .750 –16 Str. thd. ½ ” – NPT thd.

    V10P priority control covers

    Code Primary port Str. Thd Secondary port Str. thd. Tank port Str. Thd
    K   .5625 –18 .750 –16 .5625 –18
  10. SAE rated capacity (V10 cover end cartridge)
    Code
    1 – 1 USgpm
    2 – 2 USgpm
    3 – 3 USgpm
    4 – 4 USgpm
    5 – 5 USgpm
    6 – 6 USgpm
    7 – 7 USgpm
  11. Shaft seal
    Blank – Single seal
    S – Double seal
  12. Shaft type
    297 – All series
  13. Port orientation (Outlet #1)
    (Viewed from cover end of pump; refer to table on next page)
  14. Port orientation (Outlet #2)
    (Viewed from cover end of pump; refer to table on next page)
  15. Port orientation (Outlet #3 or primary outlet)
    (Viewed from cover end of pump; refer to table on next page)
  16. Controlled flow rate, V10F & V10P (Omit for standard cover)
    Code
    3 – 3 USgpm
    4 – 4 USgpm
    5 – 5 USgpm
    6 – 6 USgpm
    7 – 7 USgpm
    8 – 8 USgpm
  17. Relief valve pressure setting, V10F & V10P (Omit for standard cover)
    Code
    A – 250 psi
    B – 500 psi
    C – 750 psi
    D – 1000 psi
    E – 1250 psi
    F – 1500 psi
    G – 1750 psi
    H – 2000 psi
    J – 2250 psi
    K – 2500 psi
  18. Design (Subject to change)
  19. Rotation (Viewed from shaft end of pump)
    L – Left hand for counterclockwise
    R – Right hand for clockwise

Danfoss Vickers Vane Type Triple Pump - Figure 5NOTE
V10 cover can be assembled in any of four positions refer to drawing M –2005 –S.

13. 14. 15. Port orientation cod (Viewed from cover end of pump)

Outlet 13 #1 14 #2 15 #3
Opposite inlet A A
135° CCW from inlet A
90° CCW from inlet B B
45° CCW from inlet B
Inline with inlet C C
45° CW from inlet C
90° CW from inlet D D
135° CW from inlet D

Sharp Edges of Vane Must Lead in Direction of Rotatio

Danfoss Vickers Vane Type Triple Pump - Figure 6

NOTE
To reverse cartridge kit rotation, remove the two screws and reverse the location of the inlet support plate and the outlet support plate. Reinstall the two screws hand tight. Use pump cover to align all sections of the cartridge. Carefully remove the cover and tighten the screws.
When ordering spare cartridge parts, it is recommended they be obtained in cartridge kits. Kits are assembled and tested for either right or left hand rotation. If left hand rotation is required, it should be specified on parts order by adding suffix ”L” to cartridge kit number.

Products we offer

• Cartridge valves
• DCV directional control valves
• Electric converters
• Electric machines
• Electric motors
• Gear motors
• Gear pumps
• Hydraulic integrated circuits (HICs)
• Hydrostatic motors
• Hydrostatic pumps
• Orbital motors
• PLUS+1® controllers
• PLUS+1® displays
• PLUS+1® joysticks and pedals
• PLUS+1® operator interfaces
• PLUS+1® sensors
• PLUS+1® software
• PLUS+1® software services, support and training
• Position controls and sensors
• PVG proportional valves
• Steering components and systems
• Telematics

Danfoss Power Solutions is a global manufacturer and supplier of high-quality hydraulic and electric components. We specialize in providing state-of-the-art technology and solutions that excel in the harsh operating conditions of the mobile off-highway market as well as the marine sector. Building on our extensive applications expertise, we work closely with you to ensure exceptional performance for a broad range of applications. We help you and other customers around the world speed up system development, reduce costs and bring vehicles and vessels to market faster.
Danfoss Power Solutions – your strongest partner in mobile hydraulics and mobile electrification.
Go to www.danfoss.com for further product information.
We offer you expert worldwide support for ensuring the best possible solutions for outstanding performance. And with an extensive network of Global Service Partners, we also provide you with comprehensive global service for all of our components.
Local address:

Hydro-Gear
www.hydro-gear.com
Daikin-Sauer-Danfoss
www.daikin-sauer-danfoss.co

Danfoss
Power Solutions (US) Company
2800 East 13th Street
Ames, IA 50010, USA
Phone: +1 515 239 6000
Danfoss
Power Solutions Trading (Shanghai) Co., Ltd.
Building #22, No. 1000 Jin Hai Rd
Jin Qiao, Pudong New District
Shanghai, China 201206
Phone: +86 21 2080 6201
Danfoss
Power Solutions GmbH & Co. OHG
Krokamp 35
D-24539 Neumünster, Germany
Phone: +49 4321 871 0
Danfoss
Power Solutions ApS
Nordborgvej 81
DK-6430 Nordborg, Denmark
Phone: +45 7488 2222

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequent changes being necessary in specifications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.

Vickers Logo© Danfoss
September 2022
AX435161935866en-000101
M–2494–S
Released 08–01–95

Documents / Resources

Danfoss Vickers Vane Type Triple Pump [pdf] Owner's Manual
Vickers, Vane Type Triple Pump, Vickers Vane Type Triple Pump, Triple Pump, Pump