Danfoss-LOGO

Danfoss VHX-DUO Valve Set For Floor Connection

Danfoss-VHX-DUO-Valve-Set-For-Floor-Connection-PRODUCT

Product Specifications

  • Compatible with soft steel, copper, VPE PEX, and AluPEX tubes
  • Available dimensions: 8mm, 10mm, 12mm, 14mm, 15mm, 16mm
  • Danfoss product codes: 013G4108, 013G4110, 013G4112, 013G4114, 013G4115, 013G4116
  • Valve flange size: B (mm) – 18 for most sizes, 24 for 15mm and 16mm

Product Usage Instructions

Connection Setup

  • Ensure the return always connects to the thermostat side, with the freedom to choose left or right placement for the thermostatic element.

Fittings Installation

  • Install fittings based on the tube type being used (soft steel, copper, VPE PEX, AluPEX) and the corresponding dimensions as per the provided Danfoss codes.

 Valve Flange Attachment

  • Fix the valve flange to the radiator connections. Ensuring proper sealing.

Valve Tightening

  • Tighten the valve to the radiator, remembering to place gaskets to prevent leaks.

Presetting and kv-values Adjustment

  • Set the kv-values on the valve according to the provided table and connect the thermostat if not already done. Adjust presetting range as needed.

Mounting guide for Danfoss VHX-DUO valve set for floor connection

  • Free connection (left or right) – return always on thermostat side.

Danfoss-VHX-DUO-Valve-Set-For-Floor-Connection-FIG-1

Be aware of measurement B when cutting pipes.

Danfoss-VHX-DUO-Valve-Set-For-Floor-Connection-FIG-2 Danfoss-VHX-DUO-Valve-Set-For-Floor-Connection-FIG-3

Connect valve housing on pipes

Danfoss-VHX-DUO-Valve-Set-For-Floor-Connection-FIG-4

Fix valve flange to radiator connections.

Danfoss-VHX-DUO-Valve-Set-For-Floor-Connection-FIG-5

Lower the radiator until the flange is supported by the valve.

Danfoss-VHX-DUO-Valve-Set-For-Floor-Connection-FIG-6

Mark the position and mount the radiator on the wall.

Danfoss-VHX-DUO-Valve-Set-For-Floor-Connection-FIG-7

Tighten the valve to the radiator. NB! Remember gaskets.

Danfoss-VHX-DUO-Valve-Set-For-Floor-Connection-FIG-8

  • Presetting and kv-values for Xp = 0.5 -2K
Valve setting 1 2 3 4 5 6 7 N
kv-value (m /h) 0.12 0.15 0.20 0.25 0.30 0.36 0.42 0.49

Preset the kv on the valve and connect the thermostat if not already been done.

Danfoss-VHX-DUO-Valve-Set-For-Floor-Connection-FIG-10

013R9430 VIUYC302 © Danfoss 07/2007

FAQ

  • Q: Can I use this product with other types of tubes not listed in the manual?
    • A: The product is designed for use with soft steel, copper, VPE PEX, and AluPEX tubes, as specified in the manual. The manufacturer does not recommend using other types of tubes.
  • Q: What is the factory presetting range for this product?
    • A: The factory presetting range is marked on the valve as RAX and RTX. Consult the manual for specific values corresponding to each setting.