Danfoss RET2000 Electronic Digital Thermostat with LCD
For a large print version of these instructions please call Marketing on 0845 121 7400. Danfoss can accept no responsibility for possible errors in catalogs, brochures, and other printed material. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
Specifications
Installation Instructions
ERP Class
- The products represented within this document are classified according to, and allow completion of, the Energy Related Product (ErP) Directive System Package fiche and the ErP system data label. ErP Labelling obligation is applicable from 26th September 2015.
Mounting
- Fix at a height of 1.5m approx from the floor, away from draughts or heat sources such as radiators, open fires or direct sunlight.
Please Note:
- This product should only be installed by a qualified electrician or competent heating installer and should be in accordance with the current edition of the IEEE wiring regulations.
Wiring
RET2000B
DIL switch settings
- Slide the DIL switches to the settings required.
ON/OFF
- output switches ON when below set temperature and OFF when above. (Reverse when in cool mode)
CHRONO
- energy saving feature which fires the boiler at regular intervals to maintain a set temperature, achieving a constant ambient environment for the user.
- use 6 or 12 Cycles for radiator systems
- use 3 Cycles for underfloor heating
Heating selection
Cooling selection
Mounting
Locking and Limiting
- The RET2000 has an Advance Programming Mode in order to set up temperature lock and limit settings.
- Press the V button when in heat mode or Λ button when in cool mode until the standby mode is reached.
- The Λ button or V button should then be released and then pressed and held for a further 5 seconds to enter the Advanced Programming Mode.
- To indicate that the unit is in Advanced Programming Mode the Standby Indicator will flash and the display will show the setting number alternating with the current value for that setting.
- To change the setting press either the Λ or V button.
- A simultaneous push and release of both buttons will scroll through the steps S1 to S3 and will save the current set value if altered.
- To exit Advanced Programming Mode and return to Standby Mode press and hold both buttons for more than 5 seconds.
- While in Advanced Programming Mode if no buttons are pressed for more than 2 minutes the unit will automatically return to Standby mode, and the value on the current setting will not be saved.• A simultaneous push and release of both buttons will scroll through the steps S1 to S3 and will save the current set value if altered.
- To exit Advanced Programming Mode and return to Standby Mode press and hold both buttons for more than 5 seconds.
- While in Advanced Programming Mode if no buttons are pressed for more than 2 minutes the unit will automatically return to Standby mode, and the value on the current setting will not be saved.
S1 – Lower Temperature Limit
- This setting allows for a Lower Temperature Limit to be set. The Lower Limit can be set between 5°C (41°F) and 30°C (86°F) in Heat mode, or between 16°C (61°F) and 36°C (97°F) in Cool mode.
- Default – 5°C/41°F for Heat mode or 16°C/61°F for Cool mode.
S2 – Upper Temperature Limit
- This setting allows for a Upper Temperature Limit to be set. The Upper Limit can be set between 5°C (41°F) and 30°C (86°F) in Heat mode, or between 16°C (61°F) and 36°C (97°F) in Cool mode. However, this will be limited by the Lower Temperature Limit set in S1 therefore the Upper Temperature Limit cannot be less than the Lower Temperature Limit.
- Default – 30°C/86°F for Heat mode or 36°C/97°F for Cool mode.
S3 – Set Point Power-Up Temperature
- This setting defines the set point at power up when Button Lock is enabled on the DIL switch.
- This can be set between the Lower and Upper Temperature Limits set in S1 and S2.
- Default – 21°C/70°F for Heat mode or 24°C/75°F for Cool mode.
FAQs
Q: Can I install the RET2000 thermostat by myself?
A: The product should only be installed by a qualified electrician or competent heating installer following the IEEE wiring regulations.
Q: What is the purpose of the DIL switches on the RET2000 thermostat?
A: The DIL switches allow you to customize settings such as ON/OFF behavior, energy-saving features, and cooling selections based on your preferences.