Installation Guide
Flow Amplifier
OSQA, OSQB
1 50R99 17
OSQA Flow Amplifier
Max. tightening torque for screwed connection
Max. tightening torque for screwed connection |
||||||
Tilslutning Connection Anschluss Raccordement | ||||||
PP, LS | P, T, L, R | HP, HT, CR, CL, EF | ||||
Screwed connection | G 1/4 | 7/16-20 UNF | G 1/2 | 3/4-16 UNF |
G 3/4 | 1 1/16-12 UNF |
with cutting edge | 4 daNm 350 lbf in |
10 daNm 890 lbf in |
16 daNm 1400 lbf in |
|||
with copper washer | 2 daNm 180 lbf in |
3 daNm 270 lbf in |
5 daNm 440 lbf in |
|||
with aluminium washer | 3 daNm 270 lbf in |
8 daNm 700 lbf in |
13 daNm 1150 lbf in |
|||
with O-ring | 2 daNm 180 lbf in |
6 daNm 530 lbf in |
9 daNm 800 lbf in |
Mounting screws
M 10 × 1,5 | 3/8-16 UNC | 7/16-14 UNC |
3.0 ± 0.5 daNm | 4.0 ± 0.5 daNm | 5.5 ± 0.5 daNm |
270 ± 45 lbf in | 350 ± 45 lbf in | 490 ± 45 lbf in |
© Danfoss A/S, 2014-03 L1406554
HI.25.B4.93 • Rev BB • Mar 2014