Danfoss-MM5-VACON-100-X-Motor-Mount-Flange-LOGO

Danfoss MM5 VACON 100 X Motor Mount Flange

Danfoss-MM5-VACON-100-X-Motor-Mount-Flange-PRODUCT-IMAGE

Product Information: Vacon 100 X – Mains Switch

Specifications:

  • Document code: DPD00978B
  • Mounting instructions: MM5 example

Mounting Instructions

To mount the mains switch on the Vacon 100 X drive, follow these steps:

Step 1: Content of the Mains Switch Option Package
Refer to Figure 1 for the contents of the mains switch option package.

Danfoss-MM5-VACON-100-X-Motor-Mount-Flange-(1)

Danfoss-MM5-VACON-100-X-Motor-Mount-Flange-(2)

Drive and mains switch option.

Step 2: Disconnect the Cable Entry Plate
Locate the drive’s cable entry plate and disconnect it. This is where the mains switch will be mounted. Refer to Figure 3 for an example for MM5.

Danfoss-MM5-VACON-100-X-Motor-Mount-Flange-(3)

The mains switch can be mounted on either side of the drive. Disconnect the cable entry plate in which mains switch has to be mounted: example for MM5.

Danfoss-MM5-VACON-100-X-Motor-Mount-Flange-(4)

Cable entry plate from the bottom side of the drive from which the cables enter.

Step 3: Separate the Powerhead from the Terminal Box
Refer to Figure 5 to separate the powerhead from the terminal box.

Danfoss-MM5-VACON-100-X-Motor-Mount-Flange-(5)

Step 4: Connect the Supply Cable to the Mains Switch
Connect the supply cable to the mains switch. Refer to Figure 6 for a right-hand-side example.

Danfoss-MM5-VACON-100-X-Motor-Mount-Flange-(6)

Step 5: Connect Cables and Mount the Powerhead
Connect the cables to the mains switch and ensure they are properly connected. Then, mount the powerhead on the terminal box. Refer to Figure 7 and Figure 8 for visual guidance.

Danfoss-MM5-VACON-100-X-Motor-Mount-Flange-(7)

Danfoss-MM5-VACON-100-X-Motor-Mount-Flange-(8)

Frequently Asked Questions (FAQ)

  1. Q: Can the mains switch be mounted on either side of the drive?
    A: Yes, the mains switch can be mounted on either side of the drive.
  2. Q: Where should I disconnect the cable entry plate?
    A: Disconnect the cable entry plate in which the mains switch has to be mounted. Refer to Figure 3 for an example.
  3.  Q: How do I connect the supply cable to the mains switch?
    A: Connect the supply cable to the mains switch. Refer to Figure 6 for a right-hand-side example.
  4. Q: How do I mount the powerhead on the terminal box?
    A: After connecting the cables to the mains switch, mount the powerhead on the terminal box. Refer to Figure 8 for visual guidance.

24-hour support +358 (0)201 212 575
Email: vacon@vacon.com

Documents / Resources

Danfoss MM5 VACON 100 X Motor Mount Flange [pdf] Instruction Manual
MM5 VACON 100 X Motor Mount Flange, MM5, VACON 100 X Motor Mount Flange, X Motor Mount Flange, Mount Flange, Flange

References

Leave a comment

Your email address will not be published. Required fields are marked *