Danfoss logo

Installation guide
Pressure transmitters
MBS 5100, MBS 5103, MBS 5150, MBS 5153
060R9349 

MBS 5100 Pressure Transmitters

Danfoss MBS 5100 Pressure Transmitters - icon Electrical connection: See product label
Danfoss MBS 5100 Pressure Transmitters - ico1n EN 175301-803Danfoss MBS 5100 Pressure Transmitters - fig. Connected to enclosure
Earth
warning 2 Danfoss MBS 5100 Pressure Transmitters - fig. 1
Danfoss MBS 5100 Pressure Transmitters - icon2 ThreadDanfoss MBS 5100 Pressure Transmitters - Thread
Danfoss MBS 5100 Pressure Transmitters - fig 3 Danfoss MBS 5100 Pressure Transmitters - fig 5
Danfoss MBS 5100 Pressure Transmitters - ico12 Normal -40 – 85 °C
ATEX Zone 2 -20 – 85 °C

Danfoss MBS 5100 Pressure Transmitters - ico14Australian approvals: According to N1297.

American and Canadian approvals:

  1. Automatic electrical controls acc. to UL 60730-1 and part 2-6 / CAN/CSA E60730 and part 2-6, file E31024.
  2. Equipment for process measurement and control acc. to UL 61010-1 / CSA C22.2 No. 61010-12, file E494625.
  3. Nonincendive electrical equipement for use in Class I, Div. 2, Groups A, B, C, and D, harzardous locations in acc. To UL 121201 / C22.2 No. CSA-213, file E227388 and E510763. Combinations of equipment in systems are subject to investigation by the local Authority Having Jurisdiction at the time of installation. These components are to be installed within a suitable tool-secured enclosure in end application. WARNING – EXPLOSION HAZARD – Do not disconnect equipment unless power has been removed or the area is known to be non-hazardous.
  4. The MWP (max. working pressure) in the range from 1 to 600 bar depending on the sensor range. Refer to product lable (E494625).
  5. Evaluated for pollution Degree 3.
  6. Altitude up to 8,000 m.
  7. Max. R.H. 95% non-condensing.
  8. Overvoltage category I.
  9. Powered by class 2 supply.
Type MBS 5100, MBS 5103, MBS 5150, MBS 5153
Max. ambient temperature/(T-code) 85 °C to 135 °C (T4)
Electrical connectors For UL approved see overview page 1
Voltage supply +9 to 32 V DC
Output 4 – 20 mA

warning 2 ATEX
ZONE 2 

Danfoss MBS 5100 Pressure Transmitters - ico3 EN60079-0; EN60079-7

Applicable in ATEX Zone 2 with media classified as IIA in accordance to EN 60079-20-1:
All electrical connections must comply with the ATEX requirements for Zone 2 – and EN 60079-14.
Danfoss can accept no responsibility for possible errors in catalogs, brochures, and other printed material. Danfoss reserves the right to alter its products without notice.This also applies to products already on order provided that such alterations can be made without subsequent I changes being necessary in specifications already agreed. All trademarks in this material are the property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.

© Danfoss ‘Climate Solutions
12021.07 ANO2548642585101-00070212     

Documents / Resources

Danfoss MBS 5100 Pressure Transmitters [pdf] Installation Guide
MBS 5100, MBS 5103, MBS 5150, MBS 5153, MBS 5100 Pressure Transmitters, MBS 5100, Pressure Transmitters, Transmitters
Danfoss MBS 5100 Pressure Transmitters [pdf] Installation Guide
MBS 5100 Pressure Transmitters, MBS 5100, Pressure Transmitters, Transmitters

References

Leave a comment

Your email address will not be published. Required fields are marked *