GENERAL

Using the VACON® Flange Mounting Kit, you can mount your VACON® NX AC drive through the cabinet wall so that the control unit of the drive remains inside the cabinet.

The correct installation of the Flange Mounting Kit affects the IP protection class of the frequency converter. After the installation, the control unit is protected according to IP21 and the power unit according to IP54 (unless the frequency converter was originally IP21-protected). See figure below.
Installation Instruction

According to standard IEC 60529 (EN 60529), the IP54 AC drive enclosure provides protection against dust and water sprayed from all directions. Limited ingress of both is permitted.

VACON® FLANGE MOUNTING KIT CONTENTS

The contents of the Flange Mounting Kits for different frames are shown in the following pictures.

FR7:
Installation Instruction

  1. Flange, top
  2. Flange, bottom
  3. Flange, side
  4. Screws (5×10 TF)
  5. Screws (5×10 TX)
  6. Sealing tape

FR8:
Installation Instruction

  1. Flange, top
  2. Flange, bottom
  3. Flange, side
  4. Screws (4×8 TF)
  5. Sealing tape

FR9:

Installation Instruction

  1. Flange, top
  2. Flange, bottom
  3. Flange, side
  4. Screws (5×10 TX)
  5. Sealing tape

INSTALLATION

These instructions guide you through the installation of the Flange Mounting Kit that you have purchased for your FR7, FR8 or FR9 size AC drive.

NOTE! The sealant to be used in the flange mounting kit installation is flame retardant silicone sealant (e.g. Sika Firesil -N)

FR7

  1. Remove the three screws from both sides of the AC drive.
    Installation Instruction
  2. Remove also three screws from the top of the AC drive.
    Installation Instruction
  3. Attach the side flange to both sides with 5×10 Torx screws
    Installation Instruction
  4. Attach the top flange with three 5×10 TF screws.
    Installation Instruction
  5. Seal the two holes and the sides in the bottom of the AC drive.
    Installation Instruction
  6. Fix the cable entry flange to its place. Attach first the screws (5×10 TF) in the upper corners.
    Installation Instruction
  7. Seal the bottom flange.
    Installation Instruction
  8. Attach the bottom flange. Fasten first only the two screws (5×10 TF) in the middle
    Installation Instruction
  9. Seal the sides of the cable entry flange. Then attach the two remaining screws (5×10 TF).
    Installation Instruction
  10. Seal the sides of the frequency converter.
    Installation Instruction
  11. Seal the top flange.
    Installation Instruction
  12. Seal the small seams in each corner.
    Installation Instruction
  13. Smoothen all sealed seams with your finger. Tip your finger in soap water before smoothening the seams.
    Installation Instruction

FR8

  1. Remove these five screws from the right side of the AC drive.
    Installation Instruction
  2. Apply sealant to the right side flange.
    Installation Instruction
  3. Attach the right side flange with five screws (4×8 TF).
    Installation Instruction
  4. Repeat the steps 1-3 with the left side flange. Remove also the middle screw from this side.
    Installation Instruction
  5. Seal the bottom flange with sealing tape and attach it with four screws (4×8 TF).
    Installation Instruction
  6. Seal the top flange with sealant.
    Installation Instruction
  7. Attach the top flange with five screws (4×8 TF). See also the next picture.
    Installation Instruction
  8. Seal all seams of the top and bottom flanges with sealant.
    Installation Instruction

FR9 

  1. Before attaching the side flanges check that they are in the correct order. If the inner hole is not showing the flange is on the wrong side.
    Installation Instruction
  2. Seal the side flanges with sealant and attach them with 7 (5×10 TX) screws each.
    Installation Instruction
  3. Seal the top flange with sealant and fasten it with four screws (5×10 TX).
    Installation Instruction
  4. Fasten the sides of the top flange with two screws/side (5×10 TX).
    Installation Instruction
  5. Carefully seal all the seams of the top flange with sealant.
    Installation Instruction
  6. Seal the bottom flange with sealant and attach it four screws (5×10 TX).
    Installation Instruction
  7. Fasten the sides of the bottom flange with two screws/side (5×10 TX). Seal all seams as shown in step 5.
    Installation Instruction

MOUNTING

MOUNTING PROCEDURE

  1. Make an opening in the cabinet door for the flange (collar) installation using the dimensions given in VACON® NX User’s manual, chapter 5.
  2. Attach the sealing tape around the opening. See Figure 1
    Mounting Instruction
    for how to bend the tape at the corners of the opening (1) and place the tape so that it runs inside the screws (2). The kit contains a greater amount of tape than what you might need. Only use such an amount of tape required by the dimensions of the opening.
  3. Fit the AC drive in the opening.
    NOTE! The AC drive will not fit in the opening in a straight position. Tip the drive positioning the lower end first in the opening. See Figures 2 and 3.
    Mounting Instruction

Fix the AC drive on the plane with the screws included in the kit (FR7: M5 screws / FR8: M6 screws, FR9: M5 screws).

INFORMATION STICKER

Each Flange Mounting Kit delivered by the factory includes a sticker (shown below). Please check IP54/Collar (1) and mark the installation date (2) on the sticker. Finally, attach the sticker on the drive.
Mounting Instruction

Vacon Ltd
Member of the Danfoss Group
Runsorintie 7
65380 Vaasa
Finland

www.danfoss.com

Logo

Documents / Resources

Danfoss FR7 VACON NXP Air Cooled [pdf] Instruction Manual
FR7 VACON NXP Air Cooled, FR7, VACON NXP Air Cooled, NXP Air Cooled, Air Cooled, Cooled
Danfoss FR7 VACON NXP Air Cooled [pdf] Instruction Manual
FR7 VACON NXP Air Cooled, FR7, VACON NXP Air Cooled, NXP Air Cooled, Air Cooled, Cooled

References

Leave a comment

Your email address will not be published. Required fields are marked *