Danfoss EKE 3470P Pump and Level Controller

Product Specifications
- Model: EKE 3470P
- Application: Pump and Level controller
- Display: LCD
- Dimensions:
- Width: 110 mm (4.33 in.)
- Height: 280 mm (11 in.)
- Depth: 63 mm (2.48 in.)
- Weight: 60 mm (2.36 in.)
Product Usage Instructions
Installation
- Place the Pump and Level controller in a suitable location near the vessel.
- Connect the necessary cables and wires according to the I/O descriptions provided.
Setup and Calibration
- Power on the controller and navigate the settings using the keypad and LCD.
- Set the desired liquid level control parameters including pump start and stop conditions.
Operation
- Monitor the LCD for real-time information on liquid levels, pump status, and alarms.
- Use the keypad to adjust settings or acknowledge alarms as needed.
FAQ
- Q: How do I reset the system remotely?
- A: Use the Remote Reset function described in the Digital Input section of the manual.
- Q: What are the analog inputs used for?
- A: The analog inputs are used for monitoring parameters like liquid levels, pump motor amperage, pressure values, and temperature.
Introduction
- The EKE 3470P Pump and Level controller is a complete solution for controlling the liquid level in vessels including control and protection of pumps.
- It is easy to set up and use. The LCD and simple keypad combine to provide an easy-to-navigate, operator-friendly interface for set point and calibration entry.
- Reference: For details please see EKE 3470P Data Sheet.
Applications

Dimensions
Dimensions EKE 3470P

| I/O Descriptions | ||
| Digital Input and Output | Description | Type |
| DO 1 | High-Level Shutdown Alarm | OUTPUT |
| DO 2 | Liquid Feed Solenoid Valve #1 | OUTPUT |
| DO 3 | Liquid Feed Solenoid Valve #2 | OUTPUT |
| DO 4 | Pump #1 Start | OUTPUT |
| DO 5 | Pump #2 Start | OUTPUT |
| DO 6 | Pump #3 Start | OUTPUT |
| DO 7 | Transfer Pump Solenoid Valve | OUTPUT |
| DO 8 | Pump Bypass Solenoid Valve | OUTPUT |
| DO 9 | Superheat Oil Rectifier – Solenoid Valve | OUTPUT |
| DO 10 | General Alarm | OUTPUT |
| DO 11 | Shutdown Alarm | OUTPUT |
| DO 12 | High-Level Alarm | OUTPUT |
| DO 13 | Low-Level Shutdown Alarm | OUTPUT |
| DO 14 | Pump Mode – Evaporator Injection Signal | OUTPUT |
| DO 15 | General Alarm 1,2, 3 or Low-Level Alarm (select) | OUTPUT |
| DI 1 | System Remote Enable/Disable | INPUT |
| DI 2 | Remote Reset | INPUT |
| DI 3 | Float Switch – High-Level Shutdown Alarm (HLSD) | INPUT |
| DI 4 | Pump #1 Aux Run Contacts | INPUT |
| DI 5 | Pump #2 Aux Run Contacts | INPUT |
| DI 6 | Pump #3 Aux Run Contacts | INPUT |
| DI 7 | Float Switch – High-Level Alarm | INPUT |
| DI 8 | Float Switch – Transfer Solenoid | INPUT |
| DI 9 | Float Switch – Liquid Feed Solenoid Valve #1 | INPUT |
| DI 10 | Float Switch – Liquid Feed Solenoid Valve #2 | INPUT |
| DI 11 | Float Switch – Low-Level Alarm | INPUT |
| DI 12 | Float Switch – Low-Level Shutdown Alarm (LLSD) | INPUT |
| DI 13 | Pumps Enable/Disable | INPUT |
| DI 14 | Liquid Motorized Valve #1 Alarm | INPUT |
| DI 15 | Liquid Motorized Valve #2 Alarm | INPUT |
| DI 16 | Superheat Oil Rectifier Activation | INPUT |
| DI 17 | Stepper Valve Driver Alarm | INPUT |
| DI 18 | General Alarm 1 | INPUT |
| DI 19 | General Alarm 2 | INPUT |
| DI 20 | General Alarm 3 | INPUT |
| Analog | |||
| Analog Input and Output | Description | Signal | Type |
| AO 1 | Liquid Feed Motorized Valve #1 or Pump Speed 3 | 0–10 V | OUTPUT |
| AO 2 | Liquid Feed Motorized Valve #2 or Pump Speed 2 | 0–10 V | OUTPUT |
| AO 3 | Pump Speed 1 or All Pumps Speed(2) | 0–10 V | OUTPUT |
| AO 4 | Liquid Level Output | 0–10 V | OUTPUT |
| AO 5 | Oil Rectifier Stepper Valve Driver EKF or ICM | 0–10 V | OUTPUT |
| AI 1 | Vessel Liquid Level Probe | 4–20 mA | INPUT |
| AI 2 | Pump Motor #1 Amps | 4–20 mA | INPUT |
| AI 3 | Pump Motor #2 Amps | 4–20 mA | INPUT |
| AI 4 | Pump Motor #3 Amps | 4–20 mA | INPUT |
| AI 5 | Vessel Pressure | 4–20 mA | INPUT |
| AI 6 | Pump Discharge Pressure | 4–20 mA | INPUT |
| AI 7 | Pump Motor #1 Discharge or Delta Pressure | 4–20 mA(1) | INPUT |
| AI 8 | Pump Motor #2 Discharge or Delta Pressure | 4–20 mA(1) | INPUT |
| AI 9 | Pump Motor #3 Discharge or Delta Pressure | 4–20 mA(1) | INPUT |
| AI 10 | Oil Rectifier SH S2 Temp C | PT1000 | INPUT |
| (1) is set for 0–10 V input but conditioned externally to accept a 4–20 mA input. Pressure sensor output must be 4–20 mA
(2) Based on parameter selection |
|||
Top board

Top board – Digital Input details

Bottom board

CONTACT
- Danfoss A/S
- Climate Solutions
- danfoss.com
- +45 7488 2222
Any information, including, but not limited to information on the selection of product, its application or use, product design, weight, dimensions, capacity or any other technical data in product manuals, catalogues descriptions, advertisements, etc. and whether made available in writing, orally, electronically, online or via download, shall be considered informative and is only binding if and to the extent, explicit reference is made in a quotation or order confirmation. Danfoss cannot accept any responsibility for possible errors in catalogues, brochures, videos and other material. Danfoss reserves the right to alter its products without notice. This also applies to products ordered but not delivered provided that such alterations can be made without changes to the form, fit or function of the product.
All trademarks in this material are property of Danfoss A/S or Danfoss group companies. Danfoss and the Danfoss logo are trademarks of Danfoss A/S. All rights reserved.