Hose Assembly Instructions for Socketless Fittings

  1. To Assemble: Push hose on fitting until hose
    end bottoms underneath protective cap.
  2. Step 1: Slit hose lengthwise from protective
    cap to end of nipple.
  3. For Socketless Fittings: Low-pressure service
    – Bend hose, then snap hose off with a quick tug.

Clamp Information for Connectors

Dash Size Part Number Ear Width (mm) Band Width (mm) Size Range (mm)
-04 FF91764-162 8.0 (0.315) 7.0 (0.276) 13.5 – 16.0 (0.53 – 0.63)

Hose Assembly Instructions for FD83 and UQD Series
Connectors

  1. To Assemble: Push hose on coupling hose barb
    until hose end touches the flat surface of the coupling body.
  2. Step 1: Slit hose lengthwise from edge of
    coupling body to end of the barb.
  3. Step 2: Bend hose, then snap hose off with a
    quick tug.

Note: The use of clamp depends on the performance parameters
of the hose. Refer to hose pressure ratings for clamp
requirements.


Frequently Asked Questions (FAQ)

Q: When should I use a clamp with the connectors?

A: The use of a clamp is dependent on the
performance parameters of the hose. Please refer to the hose
pressure ratings to determine when a clamp is required.

Data Sheet: Fitting assembly with Boston EHW194 hose size -4 thru -16 For sizes -20, -24 and -32 see: Doc # AN460864287876en-000104
Hose assembly instructions
Socketless, FD83 connectors and UQD connectors

SOCKETLESS® ttings with Boston® EHW094 and EHW194 hose

To assemble

To disassemble

Step 1
Push hose on fitting until hose end bottoms underneath protective cap as shown.

Step 1
Slit hose lengthwise from protective cap to end of nipple.

SOCKETLESS fittings
Low pressure service

Step 2
Bend hose, then snap hose off with a quick tug.
Clamp location on hose tting

Clamp Information for SOCKETLESS, FD83 and UQD connectors
Ear width
Tongue-in-groove design Interlock

Dash size Part number

Reference

-04 FF91764-162 016.0-706R -06 FF91764-198 019.8-706R -08 FF91764-241 024.1-706R -10 FF91764-271 027.1-706R -12 FF91764-316 031.6-706R -16 FF91764-396 039.6-706R

Ear width mm (Inch)
8.0 (0.315) 10.0 (0.394) 10.0 (0.394) 10.0 (0.394) 10.0 (0.394) 10.0 (0.394)

Band width mm (Inch)
7.0 (0.276) 7.0 (0.276) 7.0 (0.276) 7.0 (0.276) 7.0 (0.276) 7.0 (0.276)

Size range mm (Inch)
13.5 – 16.0 (0.53 – 0.63) 16.6 – 19.8 (0.65 – 0.78) 20.9 – 24.1 (0.82 – 0.95) 23.9 – 27.1 (0.94 – 1.07) 28.4 – 31.6 (1.12 – 1.24) 36.4 – 39.6 (1.43 – 1.56)

The use of clamp is dependent on the performance parameters of hose. Please refer to hose pressure ratings for when clamp is required.

Explore our solutions danfoss.com

FD83 and UQD Series hose assembly instructions for quick disconnect coupling with Boston EHW094 & EHW194 hose

To assemble

To disassemble

Step 1
Push hose on coupling hose barb until hose end touches the flat surface of the coupling body.
FD83 series
Full-flow dual-interlock coupling
Universal Quick Disconnect (UQD)
For thermal management applications

Step 1
Slit hose lengthwise from edge of coupling body to end of the barb.

Step 2
Bend hose, then snap hose off with a quick tug.

Clamp location on hose tting

11.0mm ± 1.0mm -16 Clamp location: 11.0mm ± 1.0mm from FD83 body
Clamp location on hose tting

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.

© Danfoss | Power Solutions | 08.25 | JC

© Danfoss 2025

AN460864287876en-000104

Documents / Resources

Danfoss EHW194 Socketless Fittings with Boston [pdf] Instruction Manual
EHW194, EHW194 Socketless Fittings with Boston, Socketless Fittings with Boston, Fittings with Boston

References

Leave a comment

Your email address will not be published. Required fields are marked *