Danfoss-logo

Danfoss 102E5 Electro Mechanical Mini Programmer

Danfoss-102E5-Electro-Mechanical-Mini-Programmer

Please Note: This product should only be installed by a qualified electrician or competent heating installer, and should be in accordance with the current edition of the IEEE wiring regulations.

Product specification

Specification
Power supply 230Vac ± 15%, 50 Hz
Switching action 1 x SPST, Type 1B
Max. Switch rating 264Vac, 50/60Hz, 6(2)A
Timing Accuracy ±1 min./month
Enclosure Rating IP20
Max. Ambient Temperature 55°C
Dimensions, mm (W, H, D) 112 x 135 x 69
Design standard EN 60730-2-7
Control Pollution Situation Degree 2
Rated Impulse Voltage 2.5kV
Ball Pressure Test 75°C

Installation

Danfoss-102E5-Electro-Mechanical-Mini-Programmer-1

NB. For FRU units – go straight to to point 4 

  1. Loosen t he fixing screw in the base of the unit to release the grey plastic Wiring Cover. Ensure the protective tape over the thumbwheel remains in place.
  2. Holding the unit clockface downwards, press firmly in the centre of the wallplate and slide it from the module as shown.Danfoss-102E5-Electro-Mechanical-Mini-Programmer-2
  3. Fix the Wallplate/Terminal Block to the wall with countersunk No.8 woodscrews or to a steel box to BS 4662. 1970 or a surface mounting steel or moulded box having centres of 23/8″ (60.3mm).
  4. Referring to the Wiring Diagrams on page 6, connect the unit as shown. Ensure that terminals 3 and 6 are linked where required (Mains Voltage applications) with insulated cable capable of carrying full load current.
  5. Ensure all dust and debris has been cleared away from the area, then plug the module Þ rmly into the wallplate ensuring that the hook at the top of the wallplate engages with the slot at the back of the body. Press the module down until it locates solidly.
  6. Cut a cable aperture in the Wiring Cover if necessary; replace the Wiring Cover, and tighten the Þ xing screw.
  7. Switch on Mains & test for correct operation as follows:
    i) Remove protective tape from pre-selector wheel.
    ii) Remove dial cover & rotate the clock dial two complete revolutions to clear the mechanism.
    ii) Check that all positions of the Selector Switch and Tappets operate correctly. (See instructions in User Booklet.)
  8. Replace the dial cover. Finally leave this booklet, containing the USER instructions with the Householder.
  9. If the unit is to be left turned off and is in a dusty atmosphere, protect the pre-selector wheel by re-affixing the protective tape.

IMPORTANT: Remove tape prior to putting unit into service.

Wiring

Danfoss-102E5-Electro-Mechanical-Mini-Programmer-3

Danfoss-102E5-Electro-Mechanical-Mini-Programmer-4

  1. Typical domestic gas or oil fired system with gravity hot water and pumped heating (if a room stat is not required, wire pump L directly to terminal 2 on the 102).
  2. Fully pumped system with cylinder stat in HW circiut and room stat and 2 port spring return zone valve in heating circuit.

Your programmer

Your 102 mini-programmer allows you to switch your heating and hot water on and off at times that suit you.
Normally the 102 provides 2 ON periods and 2 OFF periods each day. However 1 ON and 1 OFF period can be obtained by using the Pre-Selector Wheel (see page 11).
You can choose whether the 102 controls your hot water & heating together, just the hot water or neither system (OFF) using the manual rocker switch.

Overview

Danfoss-102E5-Electro-Mechanical-Mini-Programmer-5

Setting the time of day
The dial on the front of the 102 displays the hours of the day using the 24 hour clock.

  • Remove dial cover (turn slightly to the left and pull off)
  • Turn the dial clockwise until the correct time is aligned to the TIME mark (as shown).

Danfoss-102E5-Electro-Mechanical-Mini-Programmer-6

IMPORTANT: turn the dial clockwise only
Remember you will have to re-set the time after a power-cut, and also when the clocks change in Spring and Autumn.

Setting the programme (Tappets A, B, C, D)

  1. If not already done so, remove the dial cover (turn slightly to the left & pull off)
  2. Decide when you want your hot water and heating to come on and go off. While gripping the dial knob slide the RED tappets to the required ON times and the BLUE tappets to the required OFF times (the tappets may be quite stiff to move)
    Note: Tappets can be moved around the dial in a clockwise or anti-clockwise direction, as convenient.

Example:
If you want your system ON between 8am and 10am and again between 4pm and 11pm, set the tappets as shown. (A to 8, B to 10, C to 16, D to 23).

Danfoss-102E5-Electro-Mechanical-Mini-Programmer-7

  • A = 1st ON
  • B = 1st OFF
  • C = 2nd ON
  • D = 2nd OFF

Remember:
Red tappets (A and C) switch ON
Blue tappets (B and D) switch OFF

3. Ensure that the installer has removed the protective tape covering the pre-selector wheel.
4. Using the dial knob, rotate the dial completely at least twice, clockwise only, to clear the mechanism.

Selecting operating mode

The Rocker Switch on the side of the unit is used to select how your 102 controls your hot water & heating system. You can manually select either:

  • hot water only
  • hot water & heating together
  • neither (system OFF)

Switch positions

Danfoss-102E5-Electro-Mechanical-Mini-Programmer-8

The 102 unit is now set, and the current status of the mini-programmer can be seen on the wheel at the top righthand corner of the unit, (e.g OFF UNTIL C).

Danfoss-102E5-Electro-Mechanical-Mini-Programmer-9

Temporary overrides

Overriding the programe using the Pre-Selector wheel
The pre-selector wheel can be used to override the set programme on occasions when you need to change from your normal heating routine.
By turning the wheel anti-clockwise you can turn the unit ON when it is OFF and vice versa.

Danfoss-102E5-Electro-Mechanical-Mini-Programmer-10

Example:

  • Your programme is set so that your heating comes on at 4pm but you arrive home earlier than usual, at 2pm and need the heating ON immediately.
  • Turn the wheel anti-clockwise until it displays ON UNTIL “D” as shown.
  • Thus the system is turned ON manually at 2pm but will revert to the set programme at the next operation (i.e. OFF at 11pm)

Some other useful pre-selections are:

ALL DAY ON (1 ON/1 OFF)
Turn the Wheel to display ON UNTIL D.

ALL DAY OFF
Turn the Wheel to display OFF UNTIL A.

Note: Do not operate the pre-selector whilst a tappet is close to the TIME mark. This may cause the time of day setting of the clock to be altered, and the time would then need to be reset.

Still having problems?

Call your local heating engineer:
Name:
Tel:

Visit our website: www.heating.danfoss.co.uk

Email our technical department: ukheating.technical@danfoss.com

Call our technical department
01234 364 621
(9:00-5:00 Mon-Thurs, 9:00-4:30 Fri)

Danfoss Ltd
Ampthill Road
Bedford
MK42 9ER
Tel: 01234 364621
Fax: 01234 219705

Documents / Resources

Danfoss 102E5 Electro Mechanical Mini Programmer [pdf] User Guide
102, 102E5, 102E7, 102E5 Electro Mechanical Mini Programmer, 102E5, Electro Mechanical Mini Programmer, Mechanical Mini Programmer, Mini Programmer, Programmer

References

Leave a comment

Your email address will not be published. Required fields are marked *