ASC2204C-S Access Controller
Product Information
Specifications
- Product: Access Controller (C)
- Version: V1.0.3
- Release Time: July 2024
Product Usage Instructions
1. Safety Instructions
Before using the Access Controller, ensure you read and
understand the safety instructions provided in the manual. The
signal words used in the manual indicate the level of potential
hazard associated with certain actions.
2. Initial Setup
Follow the initialization process outlined in the manual to set
up the Access Controller for first-time use. This may include
updating the format, wiring image, and any other relevant
settings.
3. Privacy Protection
As a user of the device, make sure to comply with privacy
protection laws and regulations when collecting personal data of
others. Implement measures to protect individuals’ rights and
interests, including providing clear identification of surveillance
areas.
Frequently Asked Questions (FAQ)
Q: What should I do if I encounter issues while using the
Access Controller?
A: If you face any problems or uncertainties with the
Controller, visit the official website, contact the supplier, or
reach out to customer service for assistance.
Access Controller (C)
User’s Manual
V1.0.3
Foreword
General
This manual introduces the structure, functions and operations of the access controller (hereinafter referred to as “the Controller”).
Safety Instructions
The following categorized signal words with defined meaning might appear in the manual.
Signal Words
Meaning
DANGER
Indicates a high potential hazard which, if not avoided, will result in death or serious injury.
WARNING CAUTION TIPS
Indicates a medium or low potential hazard which, if not avoided, could result in slight or moderate injury.
Indicates a potential risk which, if not avoided, could result in property damage, data loss, reductions in performance, or unpredictable results.
Provides methods to help you solve a problem or save time.
NOTE
Provides additional information as a supplement to the text.
Revision History
Version V1.0.3 V1.0.2 V1.0.1 V1.0.0
Revision Content Updated the format. Updated wiring image. Added initialization process. First release.
Release Time July 2024 June 2022 December 2021 March 2021
Privacy Protection Notice
As the device user or data controller, you might collect the personal data of others such as their face, fingerprints, and license plate number. You need to be in compliance with your local privacy protection laws and regulations to protect the legitimate rights and interests of other people by implementing measures which include but are not limited: Providing clear and visible identification to inform people of the existence of the surveillance area and provide required contact information.
I
About the Manual
The manual is for reference only. Slight differences might be found between the manual and the product.
We are not liable for losses incurred due to operating the product in ways that are not in compliance with the manual.
The manual will be updated according to the latest laws and regulations of related jurisdictions. For detailed information, see the paper user’s manual, use our CD-ROM, scan the QR code or visit our official website. The manual is for reference only. Slight differences might be found between the electronic version and the paper version.
All designs and software are subject to change without prior written notice. Product updates might result in some differences appearing between the actual product and the manual. Please contact customer service for the latest program and supplementary documentation.
There might be errors in the print or deviations in the description of the functions, operations and technical data. If there is any doubt or dispute, we reserve the right of final explanation.
Upgrade the reader software or try other mainstream reader software if the manual (in PDF format) cannot be opened.
All trademarks, registered trademarks and company names in the manual are properties of their respective owners.
Please visit our website, contact the supplier or customer service if any problems occur while using the Controller.
If there is any uncertainty or controversy, we reserve the right of final explanation.
II
Important Safeguards and Warnings
This section introduces content covering the proper handling of the Controller, hazard prevention, and prevention of property damage. Read carefully before using the Controller, comply with the guidelines when using it, and keep the manual safe for future reference.
Transportation Requirement
Transport the Controller under allowed humidity and temperature conditions.
Storage Requirement
Store the Controller under allowed humidity and temperature conditions.
Installation Requirements
Do not connect the power adapter to the Controller while the adapter is powered on. Strictly comply with the local electric safety code and standards. Make sure the ambient voltage is
stable and meets the power supply requirements of the Controller. Do not connect the Controller to two or more kinds of power supplies, to avoid damage to the
Controller. Improper use of the battery might result in a fire or explosion.
Personnel working at heights must take all necessary measures to ensure personal safety including wearing a helmet and safety belts.
Do not place the Controller in a place exposed to sunlight or near heat sources. Keep the Controller away from dampness, dust, and soot. Install the Controller on a stable surface to prevent it from falling. Install the Controller in a well-ventilated place, and do not block its ventilation. Use an adapter or cabinet power supply provided by the manufacturer. Use the power cords that are recommended for the region and conform to the rated power
specifications.
III
The power supply must conform to the requirements of ES1 in IEC 62368-1 standard and be no higher than PS2. Please note that the power supply requirements are subject to the Controller label.
The Controller is a class I electrical appliance. Make sure that the power supply of the Controller is connected to a power socket with protective earthing.
The Controller must be grounded when it is connected to 220 V mains electricity.
IV
Table of Contents
Foreword………………………………………………………………………………………………………………………………………… I Important Safeguards and Warnings………………………………………………………………………………………………. III 1 Overview …………………………………………………………………………………………………………………………………….. 1
Introduction …………………………………………………………………………………………………………………………………………………………… 1 Features ………………………………………………………………………………………………………………………………………………………………….. 1 Dimensions…………………………………………………………………………………………………………………………………………………………….. 1 Application …………………………………………………………………………………………………………………………………………………………….. 2
1.3.1 Two-door One-way……………………………………………………………………………………………………………………………………. 2 1.3.2 Two-door Two-way……………………………………………………………………………………………………………………………………. 3 1.3.3 Four-door One-way…………………………………………………………………………………………………………………………………… 3 1.3.4 Four-door Two-way…………………………………………………………………………………………………………………………………… 4 1.3.5 Eight-door One-way …………………………………………………………………………………………………………………………………. 4 2 Structure …………………………………………………………………………………………………………………………………….. 5 Wiring ……………………………………………………………………………………………………………………………………………………………………… 5 2.1.1 Two-door One-way……………………………………………………………………………………………………………………………………. 6 2.1.2 Two-door Two-way……………………………………………………………………………………………………………………………………. 7 2.1.3 Four-door One-way…………………………………………………………………………………………………………………………………… 8 2.1.4 Four-door Two-way…………………………………………………………………………………………………………………………………… 9 2.1.5 Eight-door One-way ………………………………………………………………………………………………………………………………..10 2.1.6 Lock…………………………………………………………………………………………………………………………………………………………….10 2.1.7 Alarm Input ……………………………………………………………………………………………………………………………………………….11 2.1.8 Alarm Output ……………………………………………………………………………………………………………………………………………11 2.1.9 Card Reader……………………………………………………………………………………………………………………………………………….13 Power Indicator…………………………………………………………………………………………………………………………………………………….13 DIP Switch……………………………………………………………………………………………………………………………………………………………..13 Power Supply………………………………………………………………………………………………………………………………………………………..14 2.4.1 Door Lock Power Port………………………………………………………………………………………………………………………………14 2.4.2 Card Reader Power Port…………………………………………………………………………………………………………………………..14 3 SmartPSS AC Configuration………………………………………………………………………………………………………… 15 Login ………………………………………………………………………………………………………………………………………………………………………15 Initialization ………………………………………………………………………………………………………………………………………………………….. 15 Adding Devices…………………………………………………………………………………………………………………………………………………….16 3.3.1 Auto Search……………………………………………………………………………………………………………………………………………….16 3.3.2 Manual Add……………………………………………………………………………………………………………………………………………….17 User Management ……………………………………………………………………………………………………………………………………………….19 3.4.1 Setting Card Type……………………………………………………………………………………………………………………………………..19 3.4.2 Adding User ………………………………………………………………………………………………………………………………………………20 Configuring Permission ………………………………………………………………………………………………………………………………………23 3.5.1 Adding Permission Group ………………………………………………………………………………………………………………………23 3.5.2 Assigning Access Permission………………………………………………………………………………………………………………….24 Access Controller Configuration………………………………………………………………………………………………………………………..25 3.6.1 Configuring Advanced Functions………………………………………………………………………………………………………….25 3.6.2 Configuring Access Controller ……………………………………………………………………………………………………………….31 3.6.3 Viewing Historical Event………………………………………………………………………………………………………………………….34
V
Access Management……………………………………………………………………………………………………………………………………………35 3.7.1 Remotely Opening and Closing Door …………………………………………………………………………………………………..35 3.7.2 Setting Door Status………………………………………………………………………………………………………………………………….36 3.7.3 Configuring Alarm Linkage…………………………………………………………………………………………………………………….37
4 ConfigTool Configuration …………………………………………………………………………………………………………… 40 Initialization ………………………………………………………………………………………………………………………………………………………….. 40 Adding Devices…………………………………………………………………………………………………………………………………………………….40 4.2.1 Adding Device Individually…………………………………………………………………………………………………………………….41 4.2.2 Adding Devices in Batches……………………………………………………………………………………………………………………..41 Configuring Access Controller …………………………………………………………………………………………………………………………..43 Changing Device Password………………………………………………………………………………………………………………………………..44 Security Recommendation ………………………………………………………………………………………….. 46
VI
1 Overview
Introduction
The Controller is an access control panel which compensates video surveillance and visual intercom. It has neat and modern design with strong functionality, suitable for high-end commercial building, group properties and smart communities.
Features
Adopts SEEC steel board to deliver a high-end appearance. Supports TCP/IP network communication. Communication data is encrypted for security. Auto registration. Supports OSDP protocol. Supports card, password and fingerprint unlock. Supports 100,000 users, 100,000 cards, 3,000 fingerprints, and 500,000 records. Supports interlock, anti-passback, multi-user unlock, first card unlock, admin password unlock,
remote unlock, and more. Supports tamper alarm, intrusion alarm, door sensor timeout alarm, duress alarm, blocklist alarm,
invalid card exceeding threshold alarm, incorrect password alarm and external alarm. Supports user types such as general users, VIP users, guest users, blocklist users, patrol users, and
other users. Supports built-in RTC, NTP time calibration, manual time calibration, and automatic time
calibration functions. Supports offline operation, event record storage and upload functions, and automatic network
replenishment (ANR). Support 128 periods, 128 holiday plans, 128 holiday periods, normally open periods, normally
closed periods, remote unlock periods, first card unlock periods, and unlock in periods. Supports watchdog guard mechanism to ensure the operation stability.
Dimensions
There are five kinds of access controllers, including two-door one-way, two-door two-way, four-door one-way, four-door two-way, and eight-door one-way. Their dimensions are the same.
1
Dimensions (mm [inch])
Application
1.3.1 Two-door One-way
Application of two-door one-way controller
2
1.3.2 Two-door Two-way
Application of two-door two-way controller
1.3.3 Four-door One-way
Application of four-door one-way controller
3
1.3.4 Four-door Two-way
Application of four-door two-way controller
1.3.5 Eight-door One-way
Application of eight-door one-way controller
4
2 Structure
Wiring
Connect the wires only when powered off. Make sure that the plug of the power supply is grounded. 12 V: Maximum current for an extension module is 100 mA. 12 V_RD: Maximum current for a card reader is 2.5 A. 12 V_LOCK: Maximum current for a lock is 2 A.
Device
Card reader
Ethernet cable Button Door contact
Table 2-1 Wire specification
Cable
Cat5 8-core shielded twisted pair
Cross-sectional Area of Each Core
0.22 mm²
Cat5 8-core shielded twisted pair
0.22 mm²
2-core
0.22 mm²
2-core
0.22 mm²
Remarks
Suggested 100 m
Suggested 100 m
5
2.1.1 Two-door One-way
Wire a two-door one-way controller
6
2.1.2 Two-door Two-way
Wire a two-door two-way controller
7
2.1.3 Four-door One-way
Wire a four-door one-way controller
8
2.1.4 Four-door Two-way
Wire a four-door two-way controller
9
2.1.5 Eight-door One-way
Wire an eight-door one-way controller
2.1.6 Lock
Select the wiring method according to your lock type. Electric lock
10
Magnetic lock Electric bolt
2.1.7 Alarm Input
The alarm input port connects to external alarm devices, such as smoke detector and IR detector. Some alarm in ports can link door open/close status.
Type
Two-door One-way
Two-door Two-way
Four-door One way
Four-door Two-way
Eight-door One-way
Table 2-2 Wiring alarm input
Number of
Alarm Input Description
Channels 2
6
Linkable door status: AUX1 external alarm links Normally Open for all doors. AUX2 external alarm links Normally Closed for all doors.
Linkable door status: AUX1AUX2 external alarm links Normally Open for all doors. AUX3A UX4 external alarm links Normally Closed for all doors.
Linkable door status:
2
AUX1 external alarm links Normally Open for all doors.
AUX2 external alarm links Normally Closed for all doors.
Linkable door status:
8
AUX1AUX2 external alarm links Normally Open for all doors.
AUX3A UX4 external alarm links Normally Closed for all doors.
Linkable door status:
8
AUX1AUX2 external alarm links Normally Open for all doors.
AUX3A UX4 external alarm links Normally Closed for all doors.
2.1.8 Alarm Output
When an alarm is triggered from the internal or external alarm input port, the alarm output device will report the alarm, and the alarm will last for 15 s.
When wiring the two-way dual-door device to the internal alarm output device, select NC/NO according to the Always Open or Always Close status. NC: Normally Closed. NO: Normally Open.
11
Type Two-door One-way
Two-door Two-way
Four-door One way
Four-door Two-way
Table 2-3 Wiring alarm output
Number of
Alarm Output Description
Channels 2
NO1 COM1 NO2 COM2
AUX1triggers alarm output. Door timeout and intrusion alarm output for door 1. Card Reader 1 tamper alarm output.
AUX2 triggers alarm output. Door timeout and intrusion alarm output for door 2. Card Reader 2 tamper alarm output.
2
NO1 COM1 NO2 COM2
AUX1/AUX2 triggers alarm output. AUX3/AUX4 triggers alarm output.
NC1
COM1
2
NO1 NC2
COM2
NO2
Card Reader 1/2 tamper alarm output. Door 1 timeout and intrusion alarm output.
Card Reader 3/4 tamper alarm output. Door 2 timeout and intrusion alarm output.
NO1
AUX1 triggers alarm output.
2
COM1
Door timeout and intrusion alarm output. Card Reader tamper alarm output.
NO2 COM2
AUX2 triggers alarm output.
NO1
AUX1 triggers alarm output.
Card Reader 1/2 tamper alarm output.
COM1
Door 1 timeout and intrusion alarm output. Device tamper alarm output.
NO2 COM2
AUX2 triggers alarm output. Card Reader 1/2 tamper alarm output. Door 2 timeout and intrusion alarm output.
NO3
AUX3 triggers alarm output.
COM3
Card Reader 5/6 tamper alarm output. Door 3 timeout and intrusion alarm output.
8
NO4
COM4
AUX4 triggers alarm output. Card Reader 7/8 tamper alarm output. Door 4 timeout and intrusion alarm output.
NO5 COM5
AUX5 triggers alarm output.
NO6 COM6
AUX6 triggers alarm output.
NO7 COM7
AUX7 triggers alarm output.
NO8 COM8
AUX8 triggers alarm output.
12
Type
Eight-door One-way
Number of Alarm Output Channels
Description NO1
COM1
NO2
COM2
NO3
COM3
NO4
8
COM4
NO5
COM5
NO6
COM6
NO7
COM7
NO8
COM8
2.1.9 Card Reader
AUX1 triggers alarm output. Card Reader 1 tamper alarm output. Door 1 timeout and intrusion alarm output. Device tamper alarm output. AUX2 triggers alarm output. Card Reader 2 tamper alarm output. Door 2 timeout and intrusion alarm output. AUX3 triggers alarm output. Card Reader 3 tamper alarm output. Door 3 timeout and intrusion alarm output.
AUX4 triggers alarm output. Card Reader 4 tamper alarm output. Door 4 timeout and intrusion alarm output. AUX5 triggers alarm output. Card Reader 5 tamper alarm output. Door 5 timeout and intrusion alarm output. AUX6 triggers alarm output. Card Reader 6 tamper alarm output. Door 6 timeout and intrusion alarm output. AUX7 triggers alarm output. Card Reader 7 tamper alarm output. Door 7 timeout and intrusion alarm output.
AUX8 triggers alarm output. Card Reader 8 tamper alarm output. Door 8 timeout and intrusion alarm output.
One door can only connect card readers of the same type, either RS-485 or Wiegand.
Table 2-4 Card reader wire specification description
Card Reader Type
RS-485 card reader
Wiegand card reader
Wiring Method RS-485 connection. The impedance of a single wire must be within 10. Wiegand connection. The impedance of a single wire must be within 2.
Length 100 m
80 m
Power Indicator
Solid green: Normal. Red: Abnormal. Flashes green: Charging. Blue: The Controller is in the Boot mode.
DIP Switch
(ON) indicates 1; indicates 0.
13
DIP switch
When 18 are all switched to 0, the Controller starts normally after power-on. When 18 are all switched to 1, the Controller enters the BOOT mode after it starts. When 1, 3, 5 and 7 are switched to 1 and the others are 0, the Controller restores to factory defaults
after it restarts. When 2, 4, 6 and 8 are switched to 1 and the others are 0, the Controller restores to factory defaults
but keeps user information after it restarts.
Power Supply
2.4.1 Door Lock Power Port
The rated voltage of the door lock power port is 12 V, and the maximum current output is 2.5 A. If the power load exceeds the maximum rated current, provide extra power supply.
2.4.2 Card Reader Power Port
Two-door one-way, two-door two-way, four-door one-way controllers: The rated voltage of the card reader power port (12V_RD) is 12 V, and the maximum current output is 1.4 A.
Four-door two-way and eight-door one-way controllers: The rated voltage of the card reader power port (12V_RD) is 12 V, and the maximum current output is 2.5 A.
14
3 SmartPSS AC Configuration
You can manage the Controller through SmartPSS AC. This section mainly introduces quick configurations of the Controller. For details, refer to SmartPSS AC user manual.
The screenshots of Smart PSS AC client in this manual are only for reference, and might differ from the actual product.
Login
Install the SmartPSS AC.
Double-click
, and then follow the instructions to finish the initialization and log in.
Initialization
Before initialization, make sure the Controller and the computer are on the same network. On the home page, select Device Manager, and then click Auto Search. Auto search
Enter a network segment range, and then click Search. Select the device, and then click Initialization. Set the admin password, and then click Next. If you forget the password, use the DIP switch to restore factory defaults.
15
Set password
Associate the phone number, and then click Next. Enter new IP, subnet mask and gateway.
Modify IP Address
Click Finish.
Adding Devices
You need to add the Controller to SmartPSS AC. You can click Auto Search to add and click Add to manually add devices.
3.3.1 Auto Search
We recommend adding devices by auto search when you need to add devices in batches within the same network segment, or when the network segment is clear but the device IP address is unclear.
Log in to SmartPSS AC. Click Device Manager on the lower-left corner.
16
Devices
Click Auto Search.
Auto search
Enter the network segment, and then click Search. A search result list will be displayed.
Click Refresh to update device information. Select a device, click Modify IP to modify IP address of the device. Select devices that you want to add to the SmartPSS AC, and then click Add. Enter the username and the login password to login. You can see the added devices on the Devices page.
The username is admin and password is admin123 by default. We recommend changing the password after login.
After adding, SmartPSS AC logs in to the device automatically. After successful login, the status displays Online. Otherwise, it displays Offline.
3.3.2 Manual Add
You can add devices manually. You need to know IP addresses and domain names of access controllers that you want to add.
Log in to SmartPSS AC.
17
Click Device Manager on the lower-left corner. Click Add on the Device Manager page.
Manual add
Enter detailed information of the Controller.
Table 3-1 Parameters
Parameter Device Name
Description Enter a name of the Controller. We recommend you name the Controller after its installation area for easy identification.
Method to add
Select IP to add the Controller through IP address.
IP
Enter IP address of the Controller. It is 192.168.1.108 by default.
Port
Enter the port number of the device. The port number is 37777 by default.
Enter the username and password of the Controller.
User Name,
Password
The username is admin and password is admin123 by default. We
recommend you change the password after login.
Click Add. The added device is on the Devices page.
18
After adding, SmartPSS AC logs in to the device automatically. After successful login, the status displays Online. Otherwise, it displays Offline.
User Management
Add users, assign cards to them, and configure their access permissions.
3.4.1 Setting Card Type
Before assigning card, set card type first. For example, if the assigned card is ID card, select type as ID card.
The selected card type must be the same as the actual assigned card type; otherwise card numbers cannot be read.
Log in to SmartPSS AC. Click Personnel Manager.
Personnel manager
On the Personnel Manager page, click
, then click
.
On the Setting Card Type window, select a card type.
Click
to select display method of card number in decimal or in hex. Setting card type
Click OK. 19
3.4.2 Adding User
3.4.2.1 Adding Individually
You can add users individually. Log in to SmartPSS AC. Click Personnel Manger > User > Add. Add basic information of the user. 1) Click the Basic Info tab on the Add User page, and then add basic information of the user. 2) Click the image, and then click Upload Picture to add a face image. The uploaded face image will display on the capture frame. Make sure that the image pixels are more than 500 × 500; image size is less than 120 KB. Add basic information
Click the Certification tab to add certification information of the user. Configure password. Set password. For the second-generation access controllers, set the personnel password; for other devices, set the card password. The new password must consist of 6 digits.
20
Configure card. The card number can be read automatically or entered manually. To read the card number automatically, select a card reader, and then place the card on the card reader. 1) Click to set Device or Card issuer to card reader. 2) The card number must be added if the non-second generation access controller is used. 3) After adding, you can set the card to main card or duress card, or replace the card with a
new one, or delete the card. Configure fingerprint. 1) Click to set Device or Fingerprint Scanner to fingerprint collector. 2) Click Add Fingerprint and press your finger on the scanner three times continuously.
Configure certification
Configure permissions for the user. For details, see “3.5 Configuring Permission”.
21
Permission configuration
Click Finish.
3.4.2.2 Adding in Batches
You can add users in batches. Log in to SmartPSS AC. Click Personnel Manger > User > Batch Add. Select card reader and the department of user. Set the start number, card quantity, effective time and expired time of card. Click Issue to assigning cards. The card number will be read automatically. Click Stop after assigning card, and then click OK.
22
Add users in batches
Configuring Permission
3.5.1 Adding Permission Group
Create a permission group that is a collection of door access permissions. Log in to SmartPSS AC. Click Personnel Manger > Permission Configuration. Permission group list
23
Click to add a permission group.
Set permission parameters. 1) Enter group name and remark. 2) Select the time template.
For details of time template setting, see SmartPSS AC user’s manual. 3) Select the corresponding device, such as door 1.
Add permission group
Click OK.
Related Operation
On the Permission Group List page, you can:
Click
to delete group.
Click to modify group information. Double-click permission group name to view group information.
3.5.2 Assigning Access Permission
Associate users with desired permission groups, and then the users will be assigned access permissions to defined doors.
Log in to SmartPSS AC.
24
Click Personnel Manger > Permission Configuration. Select the target permission group, and then click .
Configure permission
Select users to associate them with the selected group. Click OK.
Access Controller Configuration
3.6.1 Configuring Advanced Functions
3.6.1.1 First Card Unlock
Other users can swipe to unlock the door only after the specified first card holder swipes the card. You can set multiple first-cards. Other users without first-cards can unlock the door only after one of the first-card holders swipe the first card. The person to be granted with the first card unlock permission should be of the General user
type and have permissions of the certain doors. Set the type when adding users. For details, see “3.3.2 Adding User”. For details of assigning permissions, see “3.5 Configuring Permission”.
Select Access Configuration > Advanced Config. Click the First Card Unlock tab. Click Add. Configure the First Card Unlock parameters, and then click Save.
25
First card unlock configuration
Table 3-2 Parameters of first-card unlock
Parameter Door
Description Select the target access control channel to configure the first card unlock.
Timezone
First Card Unlock is valid in the period of the selected time template.
Status
After First Card Unlock is enabled, the door is in either the Normal mode or Always Open mode. Select the user to hold the first card. Supports selecting a number of users to
User
hold first cards. Any one of them swiping the first card means first card unlock is
done.
(Optional) Click . The icon changing into
indicates First Card Unlock is enabled.
The newly added First Card Unlock is enabled by default.
3.6.1.2 Multi-card Unlock
Users can only unlock the door after defined users or user groups grant access in sequence. One group can have up to 50 users, and one person can belong to multiple groups. You can add up to four user groups with multi-card unlock permission for a door, with up to 200
users in total and up to 5 valid users.
First card unlock takes priority over the multi-card unlock, which means if the two rules are both enabled, the first card unlock comes first. We recommend you not assign multi-card unlock permission to first card holders.
Do not set the VIP or Patrol type for people in the user group. For details, see “3.3.2 Adding User”.
26
For details of permission assignment, see “3.4 Configuring Permission”. Select Access Configuration > Advanced Config. Click the Multi Card Unlock tab. Add user group. 1) Click User Group. User group manager
2) Click Add.
27
User group configuration
3) Set up User Group Name. Select users from User List and click OK. You can select up to 50 users.
4) Click at the upper-right corner of the User Group Manager page. Configure parameters of multi-card unlock. 1) Click Add.
Multi-card unlock configuration (1)
28
2) Select the door. 3) Select the user group. You can select up to four groups.
Multi-card unlock configuration (2)
4) Enter the Valid Count for each group to be on site, and then select the Unlock Mode. Click or to adjust the group sequence to unlock the door.
The valid count refers to the number of users in each group that must be on site to
swipe their cards. Take Figure 3-17 as an example. The door can be unlocked only
after one person of group 1 and 2 people of group 2 have swiped their cards.
Up to five valid users are allowed.
5) Click OK.
(Optional) Click . The icon changing into
indicates Multi Card Unlock is enabled.
The newly added Multi Card Unlock is enabled by default.
3.6.1.3 Anti-passback
Users must verify their identities both for entry and exit; otherwise an alarm will be triggered. If a person enters with valid identity verification and exits without verification, an alarm will be triggered when they attempt to enter again, and access is denied at the same time. If a person enters without identity verification and exits with verification, exit is denied when the they attempt to exit.
Select Access Configuration > Advanced Config. Click Add. Configure parameters. 1) Select device and enter device name. 2) Select time template.
29
3) Set rest time and the unit is minute. For example, set the reset time as 30 minutes. If one staff has swiped in but not swiped out, the anti-pass back alarm will be triggered when this staff tends to swipe in again within the 30 minutes. The second swipe-in of this staff is only valid after 30 minutes later.
4) Click In Group and select the corresponding reader. And then click Out Group and select the corresponding reader.
5) Click OK. The configuration will issue to device and take effect. Anti-pass back configuration
(Optional) Click . The icon changing into
indicates Anti-passback is enabled.
The newly added Anti-passback is enabled by default.
3.6.1.4 Inter-door Lock
The access through one or more doors depends on the status of another door (or doors). For example, when two doors are interlocked, you can access through one door only when the other door is closed. One device supports two groups of doors with up to 4 doors in each group.
Select Access Configuration > Advanced Config. Click the Inter-Lock tab. Click Add.
30
Configure parameters and click OK. 1) Select device and enter device name. 2) Enter remark. 3) Click Add twice to add two door groups. 4) Add doors of the access controller to the needed door group. Click one door group and
then click doors to add. 5) Click OK.
Inter-door lock configuration
(Optional) Click enabled.
. The icon changing into
, which indicates Inter-door Lock is
The newly added Inter-door Lock is enabled by default.
3.6.2 Configuring Access Controller
You can configure access door, such as reader direction, door status and unlock mode. Select Access Configuration > Access Config. Click the door that needs to be configured. Configure parameters.
31
Configure access door Unlock by time period
32
Parameter Door
Reader Direction Config
Table 3-3 Parameters of access door Description Enter door name.
Click to set reader direction according to actual situations. Set door status, including Normal, Always Open and Always Close.
Status
Keep Open Timezone Keep Close Timezone Alarm
Door Sensor Administrator Password Remote Verification
Unlock Hold Interval
Close Timeout
It is not the actual door status because the SmartPSS-AC can only send commands to the device. If you want to know the actual door status, enable door sensor. Select time template when door is always open.
Select time template when door is always closed.
Enable alarm function and set alarm type, including intrusion, overtime and duress. When alarm enabled, the SmartPSS-AC will receive uploaded message when the alarm is triggered.
Enable door sensor so that you can know the actual door status. We recommend enabling the function.
Enable and set the administrator password. You can access by entering the password.
Enable the function and set the time template, and then the access of person has to be verified remotely through the SmartPSS-AC during the template periods.
Set the unlock holding interval. The door will auto close when time is over.
Set the timeout for alarm. For example, set close timeout as 60 seconds. If the door is not closed for more than 60 seconds, the alarm message will be uploaded.
Unlock Mode Click Save.
Select unlock mode as needed.
Select And, and select unlock methods. You can open the door by combining the selected unlock methods. Select Or and select unlock methods. You can open the door in one of the way that you configured. Select Unlock by time period and select unlock mode for each time period. The door can only be opened by the selected method(s) within the defined period.
33
3.6.3 Viewing Historical Event
History door events include events both on SmartPSS-AC and devices. Extract history events from devices to make sure all event logs are available to be searched for.
Add the needed personnel to the SmartPSS-AC. Click Access Configuration > History Event on the homepage. Click on the Access Manager page. Extract events from door device to the local. Click Extract, set the time, select the door device, and then click Extract Now. You can select multiple devices at one time to extract events.
Extract events
Set filtering conditions, and then click Search.
34
Search for events by filtering conditions
Access Management
3.7.1 Remotely Opening and Closing Door
You can remotely control door through SmartPSS AC. Click Access Manager on the homepage. (Or click Access Guide > ). 35
Remotely control the door. There are two methods. Method 1: Select the door, right click and select Open.
Remotely control (method 1)
Method 2: Click
or
to open or close the door.
Remotely control (method 2)
View door status by Event Info list.
Event filtering: Select the event type in the Event Info, and the event list displays events of the selected types. For example, select Alarm, and the event list only displays alarm events.
Event refresh locking: Click next to Event Info to lock or unlock the event list, and then the real-time events cannot be viewed.
Event deleting: Click next to Event Info to clear all events in the event list.
3.7.2 Setting Door Status
After setting always open status or always close status, the door remains open or closed all the time. You can click Normal to restore the door status to normal so that users can unlock the door after identity verification.
Click Access Manager on the homepage. (Or click Access Guide > ). Select the door, and then click Always Open or Always Close.
36
Set always open or always close
3.7.3 Configuring Alarm Linkage
After you configure alarm linkage, alarms will be triggered. For details, refer to the user manual of SmartPss AC. This section uses intrusion alarm as an example. Configure external alarm linkages connected to the access controller, such as smoke alarm. Configure linkages of access controller events.
Alarm event Abnormal event Normal event
For anti-pass back function, set the anti-pass back mode in Abnormal of Event Config, and then
configure the parameters in Advanced Config. For details, see “3.5.1 Configuring Advanced
Functions”.
Click Event Config on the homepage.
Select the door and select Alarm Event > Intrusion Event.
Click
next to Intrusion Alarm to enable the function.
Configure intrusion alarm linkage actions as needed.
Enable alarm sound.
Click the Notify tab, and click
next to Alarm Sound. When intrusion event
happens, the access controller warns with alarm sound.
Send alarm mail.
1) Enable Send Mail and confirm to set SMTP. The System Settings page is displayed.
2) Configure SMTP parameters, such as server address, port number, and encrypt mode.
When intrusion events occur, the system sends alarm notifications through mails to the
specified receiver.
37
Configure intrusion alarm
Configure alarm I/O. 1) Click the Alarm Output tab. 2) Select the device which supports alarm in, select alarm-in interface, and then enable
External Alarm. 3) Select the device which supports alarm out, then select alarm-out interface. 4) Enable Auto Open for the alarm linkage. 5) Set the duration.
Configure alarm linkage
Set arming time. There are two methods. Method 1: Move the cursor to set periods. When the cursor is pencil, click to add periods; when the cursor is eraser, click to remove periods. The green area is the arming periods.
38
Set arming time (method 1)
Method 2: Click
to set periods, and then click OK. Set arming time (method 2)
(Optional) If you want to set the same arming periods for other access controller, click Copy To, select the access controller, and then click OK. Click Save.
39
4 ConfigTool Configuration
ConfigTool is mainly used to configure and maintain the device.
Do not use ConfigTool and SmartPSS AC at the same time, otherwise it may cause abnormal results when you searching for devices.
Initialization
Before initialization, make sure the Controller and the computer are on the same network. Search for the Controller through the ConfigTool. 1) Double-click ConfigTool to open it. 2) Click Search setting, enter the network segment range, and then click OK. 3) Select the uninitialized Controller, and then click Initialize. Search for the device
Select the uninitialized Controller, and then click Initialize. Click OK.
The system starts initialization.
initialization failed. Click Finish.
indicates initialization success,
indicates
Adding Devices
You can add one or multiple devices according to your actual needs.
40
Make sure that the device and the PC where the ConfigTool is installed are connected; otherwise the tool cannot find the device.
4.2.1 Adding Device Individually
Click
.
Click Manual Add. Select IP Address from Add Type.
Manual add (IP address)
Set the Controller parameters.
Add Method IP Address
Table 4-1 Manual add parameters
Parameter IP Address
Description The IP address of the device. It is 192.168.1.108 by default.
Username Password
The username and password for device login.
Port
The device port number.
Click OK. The newly added device is displayed in the device list.
4.2.2 Adding Devices in Batches
You can add multiple devices through searching devices or importing the template.
41
4.2.2.1 Adding by Searching
You can add multiple devices through searching the current segment or other segments.
You can set the filtering conditions to search the wanted device quickly.
Click
.
Setting
Select the searching way. Both the following two ways are selected by default. Search current segment
Select Current Segment Search. Enter the username and password. The system will search for devices accordingly. Search other segment Select Other Segment Search. Enter the start IP address and end IP address. Enter the username and the password. The system will search for devices accordingly.
If you select both Current Segment Search and Other Segment Search, the system searches for devices on the both segments.
The username and the password are the ones used to log in when you want to modify IP, configure the system, update the device, restart the device, and more.
Click OK to start searching devices. The searched devices will be displayed in the device list.
Click
to refresh the device list.
The system saves the searching conditions when exiting the software and reuses the
same conditions when the software is launched next time.
4.2.2.2 Adding by Importing Device Template
You can add the devices by importing an Excel template. You can import up to1000 devices.
Close the template file before importing the devices; otherwise the import will fail.
42
Click , select one device, and then click Export to export a device template. Follow the on-screen instructions to save the template file locally. Open the template file, change the existing device information to the information of devices you want to add. Import the template. Click Import, select the template and click Open. The system starts importing the devices. Click OK. The newly imported devices display in the device list.
Configuring Access Controller
The screenshots and parameters might be different depending on the device types and models.
Click
on the main menu.
Click the access controller that you want to configure in the device list, and then click Get Device Info. (Optional) If the Login page shows, enter the username and password, and then click OK. Set access controller parameters.
Configure access controller
Parameter Channel
Card No.
Table 4-2 Access controller parameters Description Select the channel to set the parameters.
Set the card number processing rule of the access controller. It is No Convert by default. When the card reading result does not match the actual card No., select Byte Revert or HIDpro Convert.
Byte Revert: When access controller works with third-party readers, and the card number read by the card reader is in the reverse order from the actual card number. For example, the card number read by the card reader is hexadecimal 12345678 while the actual card number is hexadecimal 78563412, and you can select Byte Revert.
43
Parameter TCP Port
Description HIDpro Convert: When access controller works with HID Wiegand readers, and the card number read by the card reader does match the actual card number, you can select HIDpro Revert to match them. For example, the card number read by the card reader is hexadecimal 1BAB96 while the actual card number is hexadecimal 78123456,
Modify TCP port number of the Device.
SysLog
Click Get to select a storage path for system logs.
CommPort
Select the reader to set bitrate and enable OSDP.
Bitrate
If card reading is slow, you can increase bitrate. It is 9600 by default.
OSDPEnable When access controller works with third-party readers through ODSP protocol,
enable ODSP.
(Optional) Click Apply to, select the devices that you need to sync the configured
parameters to, and then click Config.
If succeeded, is displayed on the right side of the device; if failed, is displayed. You
can click the icon to view detailed information.
Changing Device Password
You can modify the device login password.
Click
on the menu bar.
Click the Device Password tab.
Device password
Click next to the device type, and then select one or multiple devices. If you select multiple devices, the login passwords must be the same. Set the password. Follow the password security level hint to set a new password.
44
Table 4-3 Password parameters
Parameter
Description
Old Password
Enter the device old password. To make sure that the old password is entered correctly, you can click Check to verify.
Enter the new password for the device. There is an indication for the
strength of the password.
New Password
The password must consist of 8 to 32 non-blank characters and contain at
least two types of characters among upper case, lower case, number, and
special character (excluding ‘ ” ; : &).
Confirm Password Confirm the new password.
Click OK to complete modification.
45
Security Recommendation
Account Management
1. Use complex passwords Please refer to the following suggestions to set passwords: The length should not be less than 8 characters; Include at least two types of characters: upper and lower case letters, numbers and symbols; Do not contain the account name or the account name in reverse order; Do not use continuous characters, such as 123, abc, etc.; Do not use repeating characters, such as 111, aaa, etc.
2. Change passwords periodically It is recommended to periodically change the device password to reduce the risk of being guessed or cracked.
3. Allocate accounts and permissions appropriately Appropriately add users based on service and management requirements and assign minimum permission sets to users.
4. Enable account lockout function The account lockout function is enabled by default. You are advised to keep it enabled to protect account security. After multiple failed password attempts, the corresponding account and source IP address will be locked.
5. Set and update password reset information in a timely manner The device supports password reset function. To reduce the risk of this function being used by threat actors, if there is any change in the information, please modify it in time. When setting security questions, it is recommended not to use easily guessed answers.
Service Configuration
1. Enable HTTPS It is recommended that you enable HTTPS to access web services through secure channels.
2. Encrypted transmission of audio and video If your audio and video data contents are very important or sensitive, it is recommended to use encrypted transmission function in order to reduce the risk of your audio and video data being eavesdropped during transmission.
3. Turn off non-essential services and use safe mode If not needed, it is recommended to turn off some services such as SSH, SNMP, SMTP, UPnP, AP hotspot etc., to reduce the attack surfaces. If necessary, it is highly recommended to choose safe modes, including but not limited to the following services: SNMP: Choose SNMP v3, and set up strong encryption and authentication passwords. SMTP: Choose TLS to access mailbox server. FTP: Choose SFTP, and set up complex passwords. AP hotspot: Choose WPA2-PSK encryption mode, and set up complex passwords.
4. Change HTTP and other default service ports It is recommended that you change the default port of HTTP and other services to any port between 1024 and 65535 to reduce the risk of being guessed by threat actors.
46
Network Configuration
1. Enable Allow list It is recommended that you turn on the allow list function, and only allow IP in the allow list to access the device. Therefore, please be sure to add your computer IP address and supporting device IP address to the allow list.
2. MAC address binding It is recommended that you bind the IP address of the gateway to the MAC address on the device to reduce the risk of ARP spoofing.
3. Build a secure network environment In order to better ensure the security of devices and reduce potential cyber risks, the following are recommended: Disable the port mapping function of the router to avoid direct access to the intranet devices from external network; According to the actual network needs, partition the network: if there is no communication demand between the two subnets, it is recommended to use VLAN, gateway and other methods to partition the network to achieve network isolation; Stablish 802.1x access authentication system to reduce the risk of illegal terminal access to the private network.
Security Auditing
1. Check online users It is recommended to check online users regularly to identify illegal users.
2. Check device log By viewing logs, you can learn about the IP addresses that attempt to log in to the device and key operations of the logged users.
3. Configure network log Due to the limited storage capacity of devices, the stored log is limited. If you need to save the log for a long time, it is recommended to enable the network log function to ensure that the critical logs are synchronized to the network log server for tracing.
Software Security
1. Update firmware in time According to the industry standard operating specifications, the firmware of devices needs to be updated to the latest version in time in order to ensure that the device has the latest functions and security. If the device is connected to the public network, it is recommended to enable the online upgrade automatic detection function, so as to obtain the firmware update information released by the manufacturer in a timely manner.
2. Update client software in time It is recommended to download and use the latest client software.
Physical Protection
It is recommended that you carry out physical protection for devices (especially storage devices), such as placing the device in a dedicated machine room and cabinet, and having access control and key management in place to prevent unauthorized personnel from damaging hardware and other peripheral equipment (e.g. USB flash disk, serial port).
47