CP825LCD Intelligent LCD UPS

Product Information

Specifications:

  • Model: CP825LCD / CP600LCD
  • Features:
    1. Power Switch
    2. Power On Indicator
    3. Mode Switch
    4. Fault Indicator
    5. LCD Module Display
    6. Battery and Surge Protected Outlets
    7. Full-Time Surge Protection Outlets
    8. USB Port
    9. Serial Port
    10. Circuit Breaker and Reset
    11. Ground Screw
    12. Outlets Designed for AC Adapters

Product Usage Instructions:

1. Safety Warnings:

Before proceeding with the installation and usage of the UPS,
please read and follow these important safety warnings:

  • Install in a temperature and humidity controlled indoor area
    free of conductive contaminants.
  • Do not remove the cover except to service the battery. Turn off
    and unplug the unit before servicing the batteries.
  • The UPS must be connected to an AC power outlet with fuse or
    circuit breaker protection. Do not plug into an outlet that is not
    grounded.
  • To avoid electric shock, turn off the unit and unplug it from
    the AC power source before servicing the battery.
  • Do not use for medical or life support equipment.
  • Do not use with or near aquariums.
  • Do not use the UPS on any transportation.

2. Installing Your UPS System:

Introduction:

Thank you for selecting a CyberPower Systems UPS product. This
UPS is designed to provide unsurpassed power protection, operation,
and performance during the lifetime of the product.

FAQ:

Q: Where can I register my product?

A: You can register your product at
www.cyberpower.com/registration to certify your product’s warranty
and receive free technical support.

“`

YOUR ULTIMATE ALLY IN POWER
INTELLIGENT LCD UPS
CP825LCD / CP600LCD
USER MANUAL

12 6
1 2
10

SERIAL

WIRING FAULT

12 7
5 3 4
11 9 8

FEATURES
1. Power Switch 2. Power On Indicator 3. Mode Switch 4. Fault Indicator 5. LCD Module Display 6. Battery and Surge Protected Outlets 7. Full-Time Surge Protection Outlets 8. USB Port 9. Serial Port 10. Circuit Breaker and Reset 11. Ground Screw 12. Outlets Designed for AC Adapters

PRODUCT REGISTRATION
Thank you for purchasing a CyberPower product. Please take a few minutes to register your product at: www.cyberpower.com/registration. Registration certifies your product’s warranty, confirms your ownership in the event of a product loss or theft and entitles you to free technical support. Register your product now to receive the benefits of CyberPower ownership.

IMPORTANT SAFETY WARNINGS (SAVE THESE INSTRUCTIONS)
This Manual Contains Important Instructions that should be followed during Installation and Maintenance of the UPS and batteries.

CAUTION! To prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor area free of conductive contaminants. (Please see specifications for acceptable temperature and humidity range).
CAUTION! To reduce the risk of electric shock, do not remove the cover except to service the battery. Turn off and unplug the unit before servicing the batteries. There are no user serviceable parts inside except for the battery.
CAUTION! Hazardous live parts inside can be energized by the battery even when the AC input power is disconnected.
CAUTION! Not for use in a computer room as defined in the Standard for the Protection of Electronic Computer/Data Processing Equipment, ANSI/NFPA 75.
CAUTION! The UPS must be connected to an AC power outlet with fuse or circuit breaker protection. Do not plug into an outlet that is not grounded. If you need to de-energize this equipment, turn off and unplug the unit.
CAUTION! To avoid electric shock, turn off the unit and unplug it from the AC power source before servicing the battery.

CAUTION! To reduce the risk of fire, connect only to a circuit provided with 20 amperes maximum branch circuit over current protection in accordance with the National Electric Code, ANSI/NFPA 70.
DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT! CyberPower Systems does not sell products for life support or medical applications. DO NOT use in any circumstance that would affect the operation and safety of life support equipment, medical applications, or patient care.
DO NOT USE WITH OR NEAR AQUARIUMS! To reduce the risk of fire or electric shock, do not use with or near an aquarium. Condensation from the aquarium can cause the unit to short out.
DO NOT USE THE UPS ON ANY TRANSPORTATION! To reduce the risk of fire or electric shock, do not use the unit on any transportation such as airplanes or ships. The effect of shock or vibration caused during transit and the damp environment can cause the unit to short out.

INSTALLING YOUR UPS SYSTEM
INTRODUCTION
Thank you for selecting a CyberPower Systems UPS product. This UPS is designed to provide unsurpassed power protection, operation and performance during the lifetime of the product.
UNPACKING
Inspect the UPS upon receipt. The box should contain the following:
(a) UPS (b) User’s manual (c) USB A+B type cable
*PowerPanel® Personal software is available on our website. Please visit www.cyberpower.com and go to the Software Section for free download.

DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT
1. Ensure that the equipment plugged into the UPS does not exceed the UPS unit’s rated capacity (825VA/450W for CP825LCD, 600A/340W for CP600LCD). If the rated capacities of the unit are exceeded, an overload condition may occur and cause the UPS unit to shut down or the circuit breaker to trip.
2. There are many factors that can affect the amount of power that your electronic equipment will require. For optimal system performance keep the load below 80% of the unit’s rated capacity.

OVERVIEW
The CP825LCD/CP600LCD provides complete power protection from utility power that is not always consistent. The CP825LCD/CP600LCD features 1030 Joules of surge protection. The unit provides long lasting battery backup during power outages with maintenance free batteries. The CP825LCD/CP600LCD ensures consistent power to your computer system and includes software that will automatically save your open files and shutdown your computer system during a utility power loss.

Cyber Power Systems (USA), Inc.

INSTALLING YOUR UPS SYSTEM – Continued

HARDWARE INSTALLATION GUIDE

1. Your new UPS may be used immediately upon receipt. However, after receiving a new UPS, to ensure the battery’s maximum charge capacity, it is recommended that you charge the battery for at least 8 hours. Your UPS is equipped with an auto-charge feature. When the UPS is plugged into an AC outlet, the battery will automatically charge whether the UPS is turned on or turned off. Note: This UPS is designed with a safety feature to keep the system from being turned on during shipment. The first time you turn the UPS on, you will need to have it connected to AC power or it will not power up.
2. With the UPS unit turned off and unplugged, connect your computer, monitor, and any other peripherals requiring battery backup into the battery power supplied outlets. Plug the other peripheral equipment (eg. printer, scanner, speakers, etc.) into the full-time surge protection outlets. DO NOT plug a laser printer, paper shredder, copier, space heater, vacuum cleaner, sump pump, or other large electrical device into the “Battery and Surge Protected Outlets”. The power demands of these devices will overload and possibly damage the unit.

3. Plug the UPS into a 2-pole, 3-wire grounded receptacle (wall outlet). Make sure the wall branch outlet is protected by a fuse or circuit breaker and does not service equipment with large electrical demands (e.g. air conditioner, refrigerator, copier, etc.). The warranty prohibits the use of extension cords, outlet strips, and surge strips in conjunction with the UPS unit.
4. Press the power switch to turn the unit on. The Power On indicator light will illuminate green and the unit will “beep” once.
5. If an overload is detected, an audible alarm will sound and the unit will emit one long beep. To correct this, turn the UPS off and unplug at least one piece of equipment from the battery power supplied outlets. Make sure the circuit breaker is depressed and then turn the UPS on.
6. To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times.
7. To store the UPS for an extended period of time, cover it and store with the battery fully charged.
8. While in storage, recharge the battery every three months to ensure optimal battery life.
9. Ensure the wall outlet and UPS are located near the equipment being attached for proper accessibility.

BASIC OPERATION
1. Power Switch: Used as the master on/off switch for equipment connected to the battery power supplied outlets. To turn the UPS ON, press the power button for approximately 2 seconds – you will hear a constant tone (1 second) – and release after a short beep.
Alarm setting: The audible alarm can be turned Off or On by double click the POWER button. The default setting is for the Alarm On. To turn the Alarm Off, double click the button. You will hear two short beeps when the Alarm is turned off. To turn the Alarm back On, double click the button. You will hear a single short beep when the Alarm is turned on. *When the Alarm is turned Off, there will be no audible notification when the UPS reaches a low battery state.
2. Power On Indicator: This LED is illuminated when the utility power is normal and the UPS outlets are providing power, free of surges and spikes.
3. Mode Switch: Press the Mode Switch for approximately 3 seconds to enter setup mode to view options: Utility High/low Voltage range, sensitivity setup, LCD sleep ON/OFF, battery test, buzzer ON/OFF, and low battery alarm. When an option is selected, wait for 8 seconds for the setting to be confirmed. After the setting has been confirmed the LCD screen will leave setup mode and go back to status display. If there is no action for 8 seconds during setup, the LCD will also leave setup mode and go back to the status display.
4. Fault Indicator: This LED is illuminated if there is a problem with the UPS.
5. LCD module display: LCD display shows all the UPS information using icons and messages. For more information please review the “Definitions for Illuminated LCD Indicators” section.

6. Battery and Surge Protected Outlets: The unit has four battery powered and surge protected outlets to ensure temporary uninterrupted operation of your equipment during a power failure. DO NOT plug a laser printer, paper shredder, copier, space heater, vacuum cleaner, sump pump, or other large electrical device into the “Battery and Surge Protected Outlets”. The power demands of these devices will overload and possibly damage the unit.
7. Full-Time Surge Protection Outlets: The unit has four surge suppression outlets. To turn the UPS OFF, press the power button for approximately 2 seconds – you will hear a constant tone (1 second) – and release after two short beeps.
8. USB Port: The USB port allows connection and communication between the USB port on the computer and the UPS unit.
9. Serial Port: Serial Port allow for bi-directional communication among the UPS and the computer. The UPS can control the computer’s shutdown in case of an emergency, and at the same time, the computer can monitor the UPS and alter its various programmable parameters.
10. Circuit Breaker & Reset: Located on the side of the UPS, the circuit breaker provides overload and fault protection.
11. Ground Screw: The ground screw is used for any equipment that needs a chassis ground connection.
12. Outlets Designed for AC Adapters: The UPS unit has four widely-spaced outlets. AC power adapters can be plugged into the UPS without overlapping or blocking adjacent outlets.

REPLACING THE BATTERY
Replacement of batteries located in an OPERATOR ACCESS AREA 1. When replacing batteries, replace with the same number of the following
battery:CyberPower / RB1290 for CP825LCD; CyberPower / RB1270B for CP600LCD 2. CAUTION! Risk of Energy Hazard, 12V, maximum 9 Ampere-hour battery. Before
replacing batteries, remove conductive jewelry such as chains, wrist watches, and rings. High energy through conductive materials could cause severe burns. 3. CAUTION! Do not dispose of batteries in a fire. The batteries may explode 4. CAUTION! Do not open or mutilate batteries. Released material is harmful to the skin and eyes. It may be toxic. 5. CAUTION! A battery can present a risk of electrical shock and high short circuit current. The following precautions should be observed when working on batteries: 1) Remove watches rings, or other metal objects. 2) Use tools with insulated handles. CAUTION – RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING TO LOCAL REGULATIONS
REMINDER: Batteries are considered HAZARDOUS WASTE and must be disposed of properly. Most retailers that sell lead acid batteries collect used batteries for recycling, as required by local regulations.

BATTERY REPLACEMENT PROCEDURE 1. Turn off and unplug all connected equipment. 2. Unplug it from the AC power source. 3. Turn the UPS upside down. 4. Remove the 1 retaining screw. 5. Slide the battery compartment cover completely off of the unit. 6. Remove the battery from the compartment. 7. Disconnect the battery cables from the battery. 8. Install the replacement battery by connecting the red wire and black wire to the
positive (+) and negative (-) terminal of the battery. 9. Put the battery back into the compartment. 10. Slide back the battery compartment cover and tighten the retaining screw. 11. Charge the unit for 8 hours to fully charge the battery.

In line mode, the AC input voltage may not stable all the time. To prevent the connected equipment from damage caused by the unexpected voltage fluctuations, please adjust the sensitivity of the unit by visiting: www.cyberpowersystems.com and download the LCD setup guide.

DEFINITIONS FOR ILLUMINATED LED INDICATORS

INPUT voltage meter: This meter measures the AC voltage that the UPS system is receiving from the utility wall outlet. The UPS is designed to continuously supply connected equipment with stable output voltage. In the event of a complete power loss, severe brownout, or over-voltage, the UPS relies on its internal battery to supply consistent 110/120 output voltage. The INPUT voltage meter can be used as a diagnostic tool to identify poor-quality input power.

The LCD display indicates a variety of UPS operational conditions. All descriptions apply when the UPS is

OUTPUT voltage meter: This meter measures, in real time, the AC voltage that the UPS system is providing to the computer during normal AC/Utility Power mode, and battery backup mode.

plugged into an AC outlet and turned on or when the UPS is on battery

ESTIMATED RUNTIME: This displays the run time estimate of the UPS with the current battery capacity and load.

NORMAL icon: This icon appears when the UPS is working under normal conditions.

BATTERY icon: During a severe brownout or blackout, this icon appears and an alarm sounds (two short beeps followed by a pause) to indicate the UPS is operating from its internal batteries. During a prolonged brownout or blackout, the alarm will sound continuously to indicate the UPS’s batteries are nearly out of power. You should save files and turn off your equipment immediately or allow the software to shut the system down.

OVER LOAD icon: This icon appears and an alarm sounds to indicate the batterysupplied outlets are overloaded. To clear the overload, unplug some of your equipment from the battery-supplied outlets until the icon turns off and the alarm stops.

BATT. CAPACITY meter: This meter displays the approximate charge level of the UPS’s internal battery in 20% increments. During a blackout or severe brownout, the UPS switches to battery power (the BATTERY icon appears) and the battery charge level decreases.

LOAD CAPACITY meter: This meter displays the approximate output load level of the UPS battery outlets in 20% increments.

SENSITIVITY meter: This meter displays the sensitivity level of the UPS. It is to control the sensitivity of the UPS to switch to Battery Mode by selecting UPS shutdown voltage range. When the sensitivity is increased, the UPS will switch to Battery Mode with less input power variation.

FAULT: The following number appears if there is a problem with the UPS. Press the POWER button to turn the UPS off.

E22: Battery Mode or AC/Utility Power Mode Overload fault (Unplug at least one piece of equipment from battery outlets and turn the UPS on again.)

E21: Battery Output Short fault (Unplug at least one piece of equipment from battery outlets and turn the UPS on again.)

E01: Charger Fault (Contact CyberPower Systems for support)

E24: Internal Fault (Contact CyberPower Systems for support)

Power On

i
Fault
Off

Alarm Off

Normal

Condition

On On On/Off
Off

Beep twice Utility Failure – The UPS is providing

Off

every 30

power to battery protected outlets from

seconds

its battery.

Rapid beeping Utility Failure – The UPS is providing

Off

every

battery power. Rapid beeping indicates

1/2 second the unit will run out of power shortly.

Flash once every 5 seconds

Constant tone

Battery Mode or AC/Utility Power Mode Overload Fault – Occurs when connected equipment exceeds the rating of battery outlets of the unit. Please unplug at least one piece of equipment from battery outlets.

Flash twice every 5 seconds

Constant tone

Battery Output Short Fault – Please unplug at least one piece of equipment from battery outlets and turn on the UPS again. If the fault still exists, please contact CyberPower Systems for support.

On

Flash 3 times every 5 seconds

Constant tone

Charger Fault – Contact CyberPower Systems for support.

TROUBLESHOOTING

Problem Circuit breaker button is projecting from the back of the unit.
The UPS does not perform expected runtime.
The UPS will not turn on.

Possible Cause Circuit breaker has been tripped due to an overload.
Battery not fully charged. Battery is worn out. The on/off switch is designed to prevent damage from rapidly turning it off and on.
The unit is not connected to an AC outlet.
The battery is worn out.
Mechanical problem.

Solution Turn the UPS off and unplug at least one piece of equipment. Wait 10 seconds, reset the circuit breaker by pressing the button, and then turn the UPS on. Recharge the battery by leaving the UPS plugged in. Contact CyberPower Systems about replacement batteries at: cyberpowersystems.com/support.
Turn the UPS off. Wait 10 seconds and then turn the UPS on.
The unit must be connected to a 120V 60Hz outlet. Contact CyberPower Systems about replacement batteries at: cyberpowersystems.com/support. Contact CyberPower Systems at: cyberpowersystems.com/support.

The USB / serial cable is not connected.

Connect the USB / serial cable to the UPS unit and an open USB / serial port on the back of the computer. You must use the cable that came with the unit.

PowerPanel® Personal is inactive (all icons are gray).

The USB / serial cable is connected to the wrong port.

Check the back of the computer for an additional USB / serial port. Move the cable to this port.

The USB power ports are not providing power to the connected devices.

The unit is not providing battery power.

Shutdown your computer and turn the UPS off. Wait 10 seconds and turn the UPS back on. This should reset the unit.

The USB power port has Over Current Protection design. When the total current of connected devices is over 2.1A, the USB power ports will stop providing power to the connected devices.

Turn the UPS off and unplug at least one piece of device connected to the USB power port and then turn the UPS on.

Additional troubleshooting information can be found at “Support” at www.CyberPowerSystems.com

TECHNICAL SPECIFICATIONS Model
Capacity Nominal Input Voltage
Input Frequency On-Battery Output Voltage On-Battery Output Frequency Max. Load for UPS Outlets Max. Load for Full-Time Surge Protection outlets
Surge Protection Operating Temperature Operating Relative Humidity Size (width x height x depth)
Net Weight Typical Battery Recharge Time
Typical Battery Life Recommended Battery
Safety Approvals

CP825LCD 825VA / 450W

CP600LCD 600VA / 340W

120Vac

60 Hz +/- 3 Hz

120Vac +/- 5%

60 Hz +/- 1%

825VA / 450W

600VA / 340W

12 A

1030 J

+ 32°F to 104° F / 0° C to 40° C

0 to 90% non-condensing

11.02 x 6.81 x 3.47 in. / 27.94 x 17.27 x 8.89 cm

13 lbs. / 5.9 kg

10.69 lbs. / 4.89 kg

8 hours to 90% capacity from total discharge

3 to 6 years, depending on number of discharge/recharge cycles

Sealed Maintenance Free Lead Acid Battery

UL1778(UPS), cUL107., FCC/DoC Class B

CYBERPOWER GREENPOWER UPSTM TECHNOLOGY

Advanced Energy-Saving Design

The GreenPower UPSTM has a high-efficiency charger, which

makes it the most energy-efficient UPS in its class. The advanced high-frequency charging system significantly improves charging

GREENPOWER UPSTM
Energy-Saving Technology

efficiency and conserves energy. As a result of this advanced

design, the GreenPower UPSTM uses less energy compared to

competitive models. The GreenPower UPSTM is manufactured in accordance with the

Restriction on Hazardous Substances (RoHS) directive making it one of the most

environmentally-friendly UPS systems on the market today.

FCC COMPLIANCE STATEMENT
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: – Reorient or relocate the receiving antenna. – Increase the separation between the equipment and receiver. – Connect the equipment to an outlet on a circuit different from that to which the receiver is connected. – Consult the dealer or an experienced radio/TV technician for help. Warning: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Canadian Compliance Statement CAN ICES-3 (B)/NMB-3(B)

LIMITED WARRANTY AND CONNECTED EQUIPMENT GUARANTEE Please visit www.CyberPowerSystems.com for a copy of the Limited Warranty and Connected Equipment Guarantee.
Where Can I Get More Information? The application of the United Nations Convention of Contracts for the International Sale of Goods is expressly excluded. CyberPower is the warrantor under this Limited Warranty. For further information please feel free to contact CyberPower at:
Cyber Power Systems (USA), Inc. 4241 12th Ave E., STE 400 Shakopee, MN 55379
call us at 877-297-6937; or submit a web ticket online at: cyberpowersystems.com/support.
Cyber Power Systems (USA), Inc. encourages environmentally sound methods for disposal and recycling of its UPS products. Please dispose and/or recycle your UPS and batteries in accordance to the local regulations of your state.
WARNING: This product can expose you to chemicals including bisphenol A (BPA) and styrene, which is known to the State of California to cause reproductive harm and cancer. For more information, go to www.P65Warnings.ca.gov.
© 2023 CyberPower Systems (USA), Inc. PowerPanel® Personal is a trademark of Cyber Power Systems(USA) Inc.
All rights reserved. All other trademarks are the property of their respective owners.

Documents / Resources

CyberPower CP825LCD Intelligent LCD UPS [pdf] User Manual
CP825LCD, CP600LCD, CP825LCD Intelligent LCD UPS, CP825LCD, Intelligent LCD UPS, LCD UPS, UPS

References

Leave a comment

Your email address will not be published. Required fields are marked *