CWL Solar Panel Brackets Performance Declaration Instructions
Declaration of Performance – Solar Panel Brackets
Product’s Unique Identification Code
Solar panel brackets installed according to M-132, M270, M-271, M-277, M-349, M-350, M-351 and M-352.
Item no. | Designation |
100185 | Mounting plate 375 x 375 mm |
100277 | Folding/pre-fabricated panel roof bracket |
410003 | Anchor plate, load-bearing roof underlay |
410009 | Solar panel bracket smooth roof/profiled sheet metal |
410016 | Solar panel bracket M10 |
410157 | Batten bracket, simplified roof underlay |
410113 | Mounting plate, shingle |
Intended Use for the Construction Product
- Attachment of solar panels and similar devices.
Manufacturer’s Name and Contact Address
CW Lundberg Industri AB
Landsvägen 52
Box 138
SE- 792 22 Mira
Sweden
Telephone number: +46 (0)250-55 35 00
E-mail: info@cwlundberg.com
Specified Performance
Item no. | Maximum load capacity perpendicular from the roof | Maximum load capacity in the direction of the roof |
100277 | 3 kN** | 2.4 kN** |
410009 | 2.5 kN* | 3.7 kN* |
410016 | 2.5 kN* | 3.7 kN* |
410113 | 5 kN | 6 kN |
100185/ 410113 +410009 | 2.5 kN | 3.7 kN |
100185/ 410113 +410016 | 2.5 kN | 3.7 kN |
100185 | 0.7-5 kN*** | 7 kN |
Essential properties | Performance | Technical specifications |
Reaction to fire | Class A1, Broof | EN 516:2006 |
Durability | At least equivalent to hot galvanisation | EN 516:2006 |
Durability | Corrosivity class C4 40 years | EN ISO 12944-2 |
* Installed on steel sheet 0.4 mm or aluminium sheet 0.8 mm ** Installed on steel sheet 0.6 mm or aluminium sheet 0.7 mm
*** Load capacity perpendicular from the roof can be raised to a maximum of 5 kN only if the designer demonstrates that the application of such a load is approved.
Other
Performance of the product specified in Sections 1 and 2 is consistent with the Performance of the product specified in Section 4. This Declaration of Performance was issued by the manufacture at its own responsibility as specified in Section 3.
The Performance of the product indicated below does not constitute a portion of the declared Performance of the product. The manufacture issues additional information about the product which affects or which may affect its use.
Other Performance
Properties | Performance | Technical specifications |
Corrosion resistance (corrosivity class C4) | 40 years | EN ISO 12944-2 |
Exterior reaction to fire (according to 7.3) | Broof | EN 516:2006 |
Requirements on PVC, ECB/FPO-based membranes
The waterproofing membrane must satisfy the requirements set out in EN 13956, as well as the following requirements:
Properties | Requirement | Technical specifications |
Tensile strength | min. 500 N/50 mm | EN 12311-2 |
Tear resistance | min. 110 N | EN 12310-2 |
Shear resistance at extensions | min. 450 N/50 mm | EN 12317-2 |
Peel strength at extensions | min. 150 N/50 mm | EN 12316-2 |
Requirements for bitumen-based membranes
The waterproofing membrane must satisfy the requirements set out in EN 13707:2004+A2:2009, as well as the following requirements:
Properties | Requirement | Technical specifications |
Tensile strength in longitudinal and transverse directions | min. 300 N/50 mm | EN 12311-1 |
Tear resistance | min. 150 N | EN 12310-1 |
Shear resistance at extension and longitudinal and transverse directions | min. 500 N/50 mm | EN 12317-1 |
Peel strength | min. 125 N/50 mm | EN 12316-1 |
Requirements for weldable EPDM membranes
The waterproofing membrane must satisfy the requirements set out in EN 13956, as well as the following requirements:
Properties | Requirement | Technical specifications |
Tensile strength | min. 400 N/50 mm | EN 12311-2 |
Tear resistance | min. 12 N | EN 12310-2 |
Shear resistance at extensions | min. 200 N/50 mm | EN 12317-2 |
Peel strength at extensions | min. 80 N/50 mm | EN 12316-2 |
Signed on behalf of the manufacturer by:
Thomas Lundberg
Managing Director
Mora, February 16, 2024
COPYRIGHT © CW Lundberg AB
T +46 (0)250 55 35 00
info@cwlundberg.com
www.cwlundberg.com
Documents / Resources
![]() |
CWL Solar Panel Brackets Performance Declaration [pdf] Instructions 100185, 100277, 410003, 410009, 410016, 410157, 410113, Solar Panel Brackets Performance Declaration, Solar Panel Brackets, Solar Panel Bracket, Brackets, Bracket, Solar Panel, Brackets Performance Declaration, Panel Performance Declaration, Performance Declaration |