CSA-IOT Co002 Connecte Smart Thermostat User Manual
Description of screen indicators
- a. ZigBee icon. The ZigBee icon will flash when the thermostat searches for networks and lights up when connected.
- b. Day (1-7, Monday-Sunday) and time. This is set automatically after a short time whenconnected to the ZigBee gateway.
- c. Home and Away mode.
- d. Heating on / off indicator. If the thermostat heats the floor, the lines will move to the right. If maximum guard is used, the lines flash if the temperature limit is exceeded.
- e. Indicator flashes when open window is detected.
- f. Manual / Auto indicator
- g. Indicates that the temperature is set.
- h. Indicator for active child lock / button lock
: On/Off button
: Inc. temp.
: Lower temp.
: Mode button
Functions
Button | Short press | Long press |
![]() |
Confirm/go back | Turn ON/OFF |
![]() |
Change between air and floor sensor (air and floor mode) | |
![]() |
Temperature increase | Enter menu |
![]() |
Open advanced settings | |
![]() |
Temperature decrease | Start ZigBee pairing |
![]() |
Lock/Unlock | |
![]() |
Change between home and away mode | Display date in MM/DD format |
To control the thermostat remotely it must be added to a ZigBee gateway
- Start the process of adding new devices to your ZigBee gateway and follow the instructions.
- To put the thermostat in pairing mode: Long press until the ZigBee icon flashes
- Continue the process of adding new devices to the app.
Advanced settings
When the thermostat is on, press and
hold and (5s) simultaneously to open advanced settings.
- You can change settings with
or
- Press
to select the settings and proceed.
- To save the changes and exit advanced settings, press
- Sensor type
00: Air sensor / Internal
01: Floor sensor / External
02: Max guard / regulator on
air temperature and limiter
with floor sensor - Floor sensor type / External
0: 10 kOhm
1: 12 kOhm
2: 15 kOhm
3: 47 kOhm - Max Guarding Temperature
This must be set in the thermostat.
20-95 ° C, Standard is 27 ° C, ‘-‘ No limit. - Turn
1-9 ° C, Standard is 2 ° C - Calibration
-9 to + 9 ° C, Standard is 0 ° C - Highest set point
35-90 ° C, Standard is 35 ° C - Lowest setpoint
0-30 ° C, Standard is 5 ° C - Home mode setpoint
The standard is 22 ° C - Setpoint for away mode
The default is 15 ° C - Brightness in sleep mode
1-10, default is 1 - Open window detection
0 = Disabled 1 = Active - Restart the system
Press + or – to change ‘-‘ to ‘==’ and wait for 5s - Reset to factory settings
Press + or – to change ‘-‘ to ‘==’ and wait for 5s
Electrical data
- Power: 230 V / 50 Hz
- Circuit breaker: Max 16 A
- Maximum load: 3600 W
- 1-pole electronic relay
- Internal power supply with galvanic isloation
- Do not use self-regulating heating cable
- Do not use for contactor control