invt EC-PG805 TTL Incremental Encoder PG Expansion Module

Předmluva
Thank you for choosing the INVT EC-PG805-05 TTL incremental encoder PG expansion module. The EC-PG805-05 TTL incremental encoder PG expansion module is used with the GD880 series VFD control box to detect the TTL or RS422 incremental encoder. The expansion module monitors the rotational speed of the motor by detecting the output signal of the encoder, providing real-time speed feedback for precise speed control. This manual describes the product overview, installation, wiring, and commissioning instructions. Before installing the VFD, read through this manual carefully to ensure proper installation and running with excellent performance and powerful functions in full play.
Vlastnosti produktu
- Incremental encoder multi-channel signal detection: IA+, IA -, IB+, IB -, IZ+, IZ-
- Provides power supply for encoders: 5V±5%/150mA
- Supports two input signal types: TTL differential signal input, RS422 signal input
- Podporuje pulzní referenci a výstup frekvenčního dělení
- With the encoder disconnection detection function, it avoids the expansion of the system fault impact
- Schopnost detekovat teplotu motoru prostřednictvím signálu teplotního senzoru KTY84/PT100
- Adopts digital filtering technology to improve electromagnetic compatibility and realize long-distance stable reception of encoder signals.
Produkt skončilview
Popis modelu

Specifikace

Tabulka 1-1 Specifikace
Technické parametry

Tabulka 1-2 Technické parametry
Poznámka: The Disconnection detection function is only supported when the motor is running.
Struktura
Figure 1-2 Component diagram

Tabulka 1-3 Popis součásti

Instalace a elektroinstalace
Bezpečnostní opatření při instalaci
Required tools: Phillips screwdriver PHl, straight screwdriver SL3

Tabulka 2-1 Screw torque requirements

Rozměry
The dimensions of the PG expansion module are 73.5x 103 x 34 mm (W*H*D).

Návod k instalaci

It is recommended to place the PG expansion module in expansion slot 1 of the control box. The following is an example instalace ve slotu 1.
Krok 1: Umístěte rozšiřující modul do odpovídající polohy rozšiřujícího slotu ovládací skříňky 1, zarovnejte jej se slotem a poté jej připevněte k sobě.
Krok 2: Align the expansion module positioning hole with the positioning stud.
Krok 3:F: Fix with an M3 screw. The installation is complete.
Poznámka
- Rozšiřující modul a ovládací skříňka jsou elektricky propojeny prostřednictvím slotů. Nainstalujte je prosím na místo.
- Chcete-li zajistit spolehlivý provoz rozšiřujícího modulu a splnit požadavky EMC, utáhněte šrouby podle doporučeného utahovacího momentu pro spolehlivé uzemnění.
Pokyny k demontáži
You disassemble the module by reversing the order of steps described in section 2.3 Installation instructions.
Krok 1: Disconnect all power supplies and disassemble all cables connected to the expansion module.
Krok 2: Use a Phillips screwdriver PHl to remove the grounding screws of the expansion module.
Krok 3: Lift the expansion module out of the control box, positioning stud, and pull it out to a suitable position. Disassembly is complete.
Uživatelský kabelový terminál


Poznámka
- The number of the PG extension module that supports the KTY84 type and that supports the PT100 type are different. Please note this when placing an order.
- The PG expansion module supports one PT100 or three PT100s for use in series.
Tabulka 2-3 Definice funkce svorky X4

Table 2-4 Function definition of RJ45 interfaces X1-X2

Figure 2-3 External wiring diagram when using EC-PG805-05

Poznámka: For the PT100 temperature sensor application (in a 3-channel series connection), J3 should be shortened.
Opatření pro elektroinstalaci
Poznámka
- Pro kabeláž kodéru uvnitř skříně je oddělte od silných rušivých kabelů (jako jsou napájecí kabely) s doporučeným odstupem 30 cm.
- U kabelů kodéru mimo skříň se vyhněte paralelnímu vedení s napájecím kabelem a vyvarujte se vytvoření prstencového tvaru. Pokud to podmínky dovolují, doporučuje se pro kabeláž použít kovovou trubku.
- To ensure high anti-interference capability in closed-loop control, you need to use a shielded wire for encoder cables and ground both ends of the cable, that is, connect the shielding layer on the motor side to the motor housing, and connect the shielding layer on the PG module side to the PE terminal.
Návod na uvedení do provozu


Table 3-1 Function code parameters related to PG expansion module.


Poznámka: For other parameter settings of the EC-PG805-05 TTL incremental encoder PG expansion module, see the software manuals of the GD880 series inverter unit.
Dokumenty / zdroje
![]() |
invt EC-PG805 TTL Incremental Encoder PG Expansion Module [pdfUživatelská příručka 66001-01189, EC-PG805 TTL Incremental Encoder PG Expansion Module, EC-PG805, TTL Incremental Encoder PG Expansion Module, Incremental Encoder PG Expansion Module, Encoder PG Expansion Module, PG Expansion Module, Expansion Module, Module |