ACiQ B0DHFF2DKL

Uživatelská příručka k centrálnímu invertorovému tepelnému čerpadlu ACiQ 2.5 Ton 17 SEER2

Model: B0DHFF2DKL

1. Úvod

This manual provides essential information for the installation, operation, and maintenance of your ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System. This system is designed to provide efficient heating and cooling for residential and light commercial applications. Please read this manual thoroughly before attempting any installation or operation to ensure proper function and safety.

2. Bezpečnostní informace

Always prioritize safety. Improper installation, adjustment, alteration, service, or maintenance can cause property damage, injury, or death. Consult a qualified installer, service agency, or the gas supplier for information or assistance. The information contained in this manual is intended for use by qualified service personnel only.

  • Elektrická bezpečnost: Ensure the power supply is disconnected before performing any service or maintenance. All electrical wiring must comply with local and national electrical codes.
  • Manipulace s chladivem: This system uses R-454B refrigerant. Only certified technicians should handle refrigerants.
  • Instalace: Installation must be performed by a licensed HVAC professional.
  • Osobní ochranné prostředky: Always wear appropriate personal protective equipment (PPE) such as gloves and safety glasses during installation and maintenance.

3. Klíčové vlastnosti

  • Invertorová technologie: Provides precise temperature control, reduced energy consumption, and quieter operation.
  • Vysoká účinnost: 18.8 SEER2 and 9.7 HSPF2 ratings for energy savings.
  • Široký provozní rozsah: Reliable performance from -13°F to 122°F.
  • Tichý provoz: Indoor noise levels as low as 44 dBA, outdoor unit at 60 dBA.
  • Odolné komponenty: Rotary compressor, aluminum coil, and fiberglass-free insulation.
  • Ekologické chladivo: Utilizes R-454B refrigerant.
  • Flexibilní instalace: Supports horizontal and vertical air handler installation.
  • Chytré ovládání: Compatible with wired controllers, WiFi, and third-party thermostats.
  • Integrated Back-up Heat: Includes a 10kW back-up heat kit for supplemental heating.

4. Komponenty přesview

The ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System includes the following main components:

  • Outdoor Condensing Unit (Heat Pump)
  • Vnitřní vzduchotechnická jednotka
  • 10kW Back-up Heat Kit
  • 30' Line Set
  • Gauge Electrical Whip
  • 60A Non-Fused Disconnect Switch
  • WiFi termostat
  • Přepěťová ochrana
  • CPS Charging Adapter
  • Nástěnný rukáv
ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System components

Obrázek 1: Nadview of the ACiQ 2.5 Ton 17 SEER2 Central Inverter Heat Pump System, showing the outdoor unit, indoor air handler, 10kW back-up heat kit, thermostat, line set, and various installation accessories.

5. Nastavení a instalace

Installation of this ACiQ heat pump system requires specialized knowledge and tools. It must be performed by a qualified and licensed HVAC technician to ensure safety, compliance with local codes, and optimal performance. Refer to the detailed installation manual provided with the product for specific instructions.

5.1 Kontroly před instalací

  • Verify that the electrical supply matches the unit's requirements (Indoor: 115/208/230V, 60Hz, 1Ph; Outdoor: 208/230V, 60Hz, 1Ph).
  • Zajistěte dostatečný prostor pro vnitřní i venkovní jednotky, aby bylo možné řádné proudění vzduchu a přístup pro údržbu.
  • Confirm that the maximum piping length (164 ft / 50m) and height difference (82 ft / 25m) are not exceeded.

5.2 Air Handler Installation

The indoor air handler unit is designed for flexible installation, supporting upflow, downflow, and horizontal configurations to suit various space requirements.

Multi-Positional Air Handler Unit installation options

Obrázek 2: Diagram illustrating the multi-positional capabilities of the indoor air handler unit, showing options for upflow, downflow, and horizontal installation.

5.3 Umístění venkovní jednotky

Consider the outdoor unit's dimensions and required clearances for optimal performance and maintenance. The unit features a compact design compared to traditional systems.

Outdoor unit size comparison with traditional units

Obrázek 3: Graphic comparing the smaller footprint of the ACiQ outdoor unit (20 inches clearance) versus a traditional unit (36 inches clearance), highlighting its high efficiency and self-cleaning features.

6. Návod k obsluze

Your ACiQ heat pump system offers advanced control options for comfortable and efficient operation.

6.1 Základní provozní režimy

  • Režim chlazení: Provides cooling with a capacity of 31,000 BTU/hr. Operates efficiently from -13°F to 122°F ambient temperatures.
  • Režim topení: Provides heating with a capacity of 30,000 BTU/hr at 47°F. Reliable warmth down to -13°F. The 10kW back-up heat kit provides supplemental heat when needed.
  • Režim ventilátoru: Cirkuluje vzduch bez ohřevu nebo chlazení.
  • Automatický režim: Automaticky přepíná mezi vytápěním a chlazením pro udržení nastavené teploty.
ACiQ outdoor unit operating in extreme heat

Obrázek 4: The ACiQ outdoor unit installed on a patio, demonstrating its ability to operate effectively in extreme heat conditions, up to 122°F.

ACiQ outdoor unit operating in extreme cold

Obrázek 5: The ACiQ outdoor unit partially covered in snow, illustrating its capability to operate in extreme cold temperatures, down to -13°F.

6.2 Smart Controls

The system can be controlled via the included wired thermostat, WiFi-enabled app, or compatible third-party thermostats. The WiFi app allows for remote control and monitoring of your system.

ACiQ Smart Home app and wired thermostat

Obrázek 6: Image showing the ACiQ Smart Home mobile application interface on a smartphone alongside a wired thermostat, demonstrating the system's smart control capabilities for climate management.

7. Údržba

Regular maintenance ensures the longevity and efficiency of your ACiQ heat pump system. Always disconnect power before performing any maintenance.

  • Výměna vzduchového filtru: Check and replace air filters in the indoor air handler every 1-3 months, or more frequently if needed. Dirty filters restrict airflow and reduce efficiency.
  • Čištění venkovní jednotky: Keep the outdoor unit free from debris, leaves, and dirt. Periodically clean the coils with a soft brush or water hose (ensure power is off).
  • Drenážní systém: Ensure the condensate drain line is clear and free of blockages to prevent water overflow.
  • Odborná kontrola: Schedule annual inspections and maintenance by a qualified HVAC technician.

8. Řešení problémů

This section provides solutions for common issues. For complex problems, contact a qualified HVAC technician.

  • Bez napájení: Check circuit breakers and ensure the disconnect switch is in the ON position.
  • Nedostatečné vytápění/chlazení: Verify thermostat settings, check air filters for blockage, and ensure outdoor unit is not obstructed.
  • Neobvyklé zvuky: Minor operational noises are normal. Loud or unusual noises may indicate a problem requiring professional inspection.
  • Úniky vody: Check condensate drain line for blockages.

9. Specifikace

Dimensions of ACiQ indoor and outdoor units

Obrázek 7: Image displaying the dimensions of both the indoor air handler unit (49.02" H x 21.02" W x 21.02" D) and the outdoor condensing unit (35.04" H x 37.24" W x 16.14" D).

Cooling capacity chart for ACiQ heat pump

Obrázek 8: Chart detailing the cooling capacity of the ACiQ system at various outdoor temperatures: 86°F (118% capacity), 95°F (113% capacity), 110°F (99% capacity), and 122°F (48% capacity).

Heating capacity chart for ACiQ heat pump

Obrázek 9: Chart detailing the heating capacity of the ACiQ system at various outdoor temperatures: -22°F (N/A), -13°F (41% capacity), 0°F (57% capacity), 17°F (70% capacity), and 32°F (73% capacity).

FunkceDetail
Chladicí kapacita31,000 BTU/hod
Topný výkon30,000 BTU/hr (at 47°F)
Hodnocení SEER218.8
Hodnocení HSPF29.7
Typ chladivaR-454B
Napájení vnitřní jednotky115/208/230V, 60Hz, 1Ph
Napájení venkovní jednotky208/230 V, 60 Hz, 1 fáze
Maximální délka potrubí164 stop (50 m)
Maximální výškový rozdíl82 stop (25 m)
Indoor Unit Dimensions (W × D × H)21.02" × 21.02" × 49.02"
Outdoor Unit Dimensions (W × D × H)37.24" × 16.14" × 31.89"
Čistá hmotnost vnitřní jednotky128.97 liber
Čistá hmotnost venkovní jednotky164.02 liber

10. Záruka a podpora

ACiQ offers a comprehensive warranty for this heat pump system:

  • Záruka na díly: 7 roky
  • Záruka na kompresor: 12 roky

These warranty terms are valid when the system is installed by a certified technician and registered online with the manufacturer. For technical support, service inquiries, or warranty claims, please refer to the contact information provided in your product packaging or visit the official ACiQ webmísto.

Související dokumenty - B0DHFF2DKL

Předview Standardní jednozónové topné systémy ACiQ 9K-24K: Instalační a uživatelská příručka
Instalační a uživatelská příručka pro standardní jednozónové systémy vytápění ACiQ 9K-24K. Tato příručka podrobně popisuje instalaci, provoz, bezpečnost a údržbu klimatizací ACiQ, včetně specifikací modelu a informací o chladivu R454B.
Předview Instalační manuál centrálních invertorových systémů ACiQ
Komplexní instalační manuál pro centrální invertorové klimatizační a tepelné čerpadla ACiQ s podrobným popisem bezpečnostních opatření, potrubí chladiva, instalace venkovní jednotky, zapojení, specifikací napájení, odsávání vzduchu a postupů zkušebního provozu.
Předview Nástěnná klimatizační jednotka ACiQ a jednozónová kondenzační jednotka pro extrémní teplo – instalační a uživatelská příručka
Tato příručka obsahuje podrobné pokyny k instalaci, provozu a bezpečnosti pro nástěnné vzduchotechnické jednotky ACiQ a extrémně horké jednozónové kondenzační jednotky, které zahrnují modely ACIQ-06W-HH-MD až ACIQ-24ZPL-HP230C.
Předview Instalační manuál venkovní jednotky centrálního invertorového systému ACiQ
Komplexní instalační manuál pro venkovní jednotky centrálních invertorových systémů ACiQ, který zahrnuje bezpečnostní opatření, potrubí chladiva, zapojení, instalaci jednotky a testovací postupy pro modely jako ACiQ-18-AC, ACiQ-24-AC, ACiQ-18-EHPB a další.
Předview Systém tepelného čerpadla ACiQ Next Gen s potrubím: Stručný návod k zapojení termostatu
Tato příručka poskytuje základní informace o připojení a zapojení termostatů k systému tepelných čerpadel ACiQ Next Gen s potrubím. Podrobně popisuje doporučené a alternativní možnosti připojení, včetně nastavení DIP přepínačů a konfigurace svorkovnic pro různé typy termostatů.
Předview Instalační a uživatelská příručka pro minisplitovou jednotku a kondenzátor ACiQ Essentials
Komplexní instalační a uživatelská příručka pro vzduchotechnické a kondenzační systémy ACiQ Essentials Mini-Split, která zahrnuje bezpečnostní opatření, identifikaci dílů, ovládání dálkovým ovládáním, instalační postupy, zkušební provoz, údržbu a řešení problémů u různých modelů. Příručka také obsahuje důležité informace týkající se servisu systémů používajících hořlavé chladivo R454B s důrazem na bezpečnostní protokoly a dodržování předpisů. Je určena pro profesionální instalační techniky a koncové uživatele, aby byl zajištěn bezpečný a efektivní provoz systémů tepelných čerpadel ACiQ Mini-Split.