1. Úvod a konecview
This manual provides essential instructions for the safe and efficient operation, installation, and maintenance of your Airwell 7MB021061 Mobile Air Conditioner. Please read this manual thoroughly before using the appliance and retain it for future reference.

Obrázek 1: Přední view of the Airwell 7MB021061 Mobile Air Conditioner. This image displays the compact, white unit with the Airwell logo subtly embossed on the front panel. A handle is visible on the top right side for portability, and a grey exhaust port is partially visible on the right side.
2. Vlastnosti produktu
- Všestranná funkčnost: Offers cooling-only operation.
- Přenosnost: Equipped with wheels and integrated carrying handles for easy movement.
- Dálkové ovládání: Součástí je dálkové ovládání pro pohodlné ovládání.
- Okenní sada: Supplied with an installation kit suitable for standard windows and walls.
- Funkce odvlhčovače: Capable of reducing humidity levels in the room.
- "I Feel" Comfort: Features a temperature sensor located in the remote control for precise temperature regulation based on the remote's location.
- Ekologické chladivo: Utilizes R290 refrigerant, which has a very low environmental impact.
- Ovládací displej: An integrated control display is present on the unit.
- Condensate Reduction: Designed with condensate evaporation on the exchanger.
3. Nastavení a instalace
Proper setup is crucial for optimal performance and safety. Follow these general guidelines:
- Rozbalení: Klimatizační jednotku a veškeré příslušenství opatrně vyjměte z obalu. Obal si uschovejte pro budoucí skladování nebo přepravu.
- Umístění: Position the unit on a flat, stable surface, ensuring adequate clearance around the unit for proper airflow. Avoid placing it near heat sources or in direct sunlight.
- Instalace výfukové hadice:
- Attach the exhaust hose to the designated outlet on the rear of the air conditioner.
- Utilize the provided window kit to securely vent the hot air outside through a window or wall opening. Ensure the hose is as straight and short as possible to maximize efficiency.
- Připojení napájení: Zapojte napájecí kabel do uzemněné elektrické zásuvky. Ujistěte se, že hlasitosttage odpovídá specifikacím jednotky.
4. Návod k obsluze
The Airwell 7MB021061 can be operated via the control display on the unit or the included remote control.
4.1. Obsluha ovládacího panelu
Refer to the icons and buttons on the unit's control display for direct adjustments to settings such as power, mode selection (Cool, Dehumidify), fan speed, and temperature.
4.2. Dálkové ovládání
The remote control provides full functionality from a distance. Insert batteries as indicated in the remote's compartment.
- Vypínač: Zapíná nebo vypíná jednotku.
- Výběr režimu: Cycle through available modes (Cool, Dehumidify).
- Nastavení teploty: Pomocí šipek nahoru/dolů nastavte požadovanou teplotu.
- Rychlost ventilátoru: Adjust the fan speed (Low, Medium, High).
- "I Feel" Function: Activate this function for enhanced comfort. The remote control's built-in sensor will measure the ambient temperature at its location and adjust the air conditioner's operation to maintain the set temperature around the remote. Ensure the remote is placed in a central area of the room.
5. Údržba
Pravidelná údržba zajistí dlouhou životnost a účinnost vaší klimatizace.
- Čištění filtru: The air filter should be cleaned regularly (e.g., every two weeks, depending on usage) to prevent dust buildup and maintain airflow. Refer to the unit's specific instructions for filter removal and cleaning.
- Čištění exteriéru: Otřete vnější část jednotky měkkým, damp tkanina. Nepoužívejte agresivní chemikálie nebo abrazivní čisticí prostředky.
- Skladování: Before long-term storage, ensure the unit is thoroughly drained of any accumulated water. Clean the filters and store the unit in a dry, cool place, preferably in its original packaging.
6. Řešení problémů
If you encounter issues with your air conditioner, consult the following basic troubleshooting steps:
- Jednotka se nezapne: Check if the power cord is securely plugged into a functional outlet. Ensure the unit's power button is pressed and the remote control batteries are not depleted.
- Nedostatečné chlazení: Verify that the exhaust hose is properly installed and venting hot air outside. Check if air filters are clean and not obstructed. Ensure windows and doors are closed to prevent warm air entry.
- Neobvyklý hluk: Ensure the unit is on a flat, stable surface. Check for any obstructions around the fan or air inlets/outlets.
- Únik vody: Ensure the unit is level. If the unit has a drain plug, check if it is securely closed, unless continuous drainage is intended.
V případě přetrvávajících problémů kontaktujte zákaznickou podporu nebo kvalifikovaného technika.
7. Specifikace
| Funkce | Hodnota |
|---|---|
| Číslo modelu | 7 MB021061 |
| Nominal Cooling Power | 3.52 kW |
| Moc | 3520 W |
| Spotřeba energie | 1.357 kW |
| Proud | 5.9 A |
| Operating Limits (Dry Bulb) | 17 ° C / 35 ° C |
| Sound Pressure Level (PV/MV/GV at 1m) | 50/51/52 dB(A) |
| Hladina akustického výkonu | 63 dB(A) |
| Airflow (PV/MV/GV) | 355/370/420 m³/h |
| Odvlhčovací kapacita | 1.8 l/h |
| Třída energetické účinnosti | A+ |
| Chladivo | R290 |
| Šířka | 467 mm |
| Výška | 765 mm |
| Hloubka | 397 mm |
| Hmotnost | 33 kg |
8. Záruka a podpora
The Airwell 7MB021061 Mobile Air Conditioner comes with a 1-letá záruka od data nákupu.
For warranty claims, technical support, or service inquiries, please contact your retailer or the official Airwell customer service. Ensure you have your proof of purchase and the product model number (7MB021061) available when contacting support.