1. Úvod
The SINOTIMER STVP series automatic over-voltage a pod-zvtage protector is designed for three-phase 3*127V/220VAC power systems with a rated working current of 80A. This device provides essential protection for electrical equipment by instantaneously cutting off the power supply when over-voltage, pod-voltage, or over-current conditions are detected. Once the circuit voltage returns to normal, the protector automatically restores power, ensuring continuous operation and safeguarding your appliances from damage.
This protector integrates multiple protection functions including over-voltage, pod-voltage, over-current, three-phase current (voltage) imbalance, phase sequence (reverse phase), zero-break, and phase-break protection. It also features voltmeter and ammeter functions, and the ability to restore factory settings. The device offers comprehensive features, stable performance, and ease of operation.
Podrobný návod k použití ve formátu PDF je k dispozici ke stažení: Uživatelská příručka (PDF)
2. Klíčové vlastnosti
- Voltage ochrana
- Pod voltage ochrana
- Nadproudová ochrana
- Automatické obnovení
- svtage display (separate ABC phase voltage měření)
- Ampere display (separate ABC phase ampere measurement)
- Třífázový ampere unbalance protection
- Phase sequence protection (reverse phase protection)
- Zero line break protection
- Ochrana proti výpadku fáze
- Fault inquiry function
- Rotation display of voltage and current for each phase
- Nastavitelný přetlaktage protection value and recovery value
- Adjustable under-voltage protection value and recovery value
- Adjustable over-current protection value and action time
- Adjustable 3-phase ampere unbalance protection value and action time
- Adjustable delay time after power-on
- Adjustable fault recovery delay time
- Factory data reset function
3. Specifikace produktu
| Atribut | Hodnota |
|---|---|
| Číslo modelu | STVP936-1-80A |
| Napájení | 3*127V/220VAC 60Hz |
| Jmenovitý objemtage | 220V |
| Fáze | Třífázové |
| Max. Zatěžovací proud | 1~80A Adjustable (default: 80A) |
| VoltagRozsah ochrany e | 121V-150V-OFF Adjustable (default: 140V) |
| VoltagRozsah zotavení e | 120V-149V (default: 135V) |
| Voltage Čas akce | 0.1~10 seconds (default: 0.2s) |
| Pod voltagRozsah ochrany e | 118V-80V-OFF Adjustable (default: 90V) |
| Pod voltagRozsah zotavení e | 118V-91V (default: 95V) |
| Pod voltage Čas akce | 0.1~10 seconds (default: 0.2s) |
| 3-Phase Volt Unbalance Protection | 10%~50%~OFF (default: 20%) |
| 3-Phase Volt Unbalance Action Time | 0.1~10 seconds (default: 1s) |
| Delay Time After Power-on | 2~255 seconds (default: 2s) |
| Fault Recovery Delay Time | 2~600 seconds (default: 60s) |
| Zobrazit model | LCD |
| Rozměry | 71.5 mm (Š) * 95.2 mm (V) * 65.7 mm (H) |
| Instalace | 35 mm DIN lišta |
| Osvědčení | CE, RoHS |
4. Bezpečnostní informace
- Instalaci a údržbu by měli provádět pouze kvalifikovaní elektrikáři.
- Před jakoukoli instalací nebo elektroinstalačními pracemi se ujistěte, že je odpojeno napájení.
- The device does not provide overload or short-circuit protection. It must be used in conjunction with appropriate external circuit breakers (e.g., C45, C65 mini circuit breakers) for comprehensive protection.
- Před připojením napájení zkontrolujte, zda jsou všechna zapojení bezpečná a správná.
- Do not operate the device in wet or hazardous environments.
5. Instalace
5.1 Fyzické rozměry

5.2 Montáž
The protector is designed for 35mm DIN rail installation. Snap the device onto the DIN rail securely.

5.3 Schéma zapojení
Connect the input and output terminals as shown in the diagram below. Ensure correct phase (L1, L2, L3) and neutral (N) connections. The input terminals are located at the top, and output terminals at the bottom.


6. Nastavení a konfigurace
Chcete-li vstoupit do režimu nastavení, stiskněte a podržte tlačítko SOUBOR button for 3 seconds. Then, continuously press SOUBOR to cycle through the parameters. Use the ▲ a ▼ buttons to adjust the values. When "ENd" appears, press SOUBOR again to save the data and exit the setting mode.
If no operation is performed within 10 seconds after pressing SOUBOR, the device will automatically exit the setting mode, and any unsaved changes will be lost.
6.1 Parameter Settings Table
| Krok | Obsah | LCD displej | Description / Range (Default) |
|---|---|---|---|
| 1 | Voltage ochranná hodnota | Uvo 280V | 221V-300V-OFF (280V) |
| 2 | Voltage hodnota výtěžnosti | Uvor 250V | 220V-299V (250V) |
| 3 | Voltage protection action time | 0.2S | 0.1–10 s (0.2 s) |
| 4 | Pod voltage ochranná hodnota | Uve 160V | 219V-150V-OFF (160V) |
| 5 | Pod voltage hodnota výtěžnosti | Uver 180V | 151V-220V (180V) |
| 6 | Pod voltage protection action time | 0.2S | 0.1–10 s (0.2 s) |
| 7 | Hodnota nadproudové ochrany | >In 80A | 1-80A (80A) |
| 8 | Over-current protection action time | 5S | 1–512 s (5 s) |
| 9 | 3 fáze amp unbalance protection value | >In % | 5%-90%-OFF (25%). Not active if current < 2A. |
| 10 | 3 fáze amp unbalance protection action time | 1.0 S | 0.1–10 s (1 s) |
| 11 | Ochrana sledu fází | ON ABC | ON or OFF (ON) |
| 12 | Doba zpoždění zapnutí | 2 S | 2–255 s (2 s) |
| 13 | Fault recovery delay time | 60 S | 2–512 s (60 s) |
| 14 | Fault inquiry code | E0 | Press ▲ to view last 5 fault records (E1-E5). >U for overvoltage, <U for undervoltage. |
| 15 | Konec | Konec | Press SET to save and exit. |
6.2 Obnovení továrního nastavení
To reset the device to factory settings, press and hold the ▲ a ▼ tlačítka současně po dobu 3 sekund.
7. Provoz
Once installed and configured, the device will continuously monitor the three-phase power supply. The LCD screen will automatically rotate to display the real-time voltage and current for each phase (L1, L2, L3).
V případě přeobjtage, pod-voltage, or over-current event, the protector will automatically trip and cut off the power supply to protect connected equipment. After the fault condition clears and the recovery delay time has passed, the device will automatically restore power.
8. Řešení problémů
8.1 Dotazování poruch
If a fault occurs, the device will display an error code (E0). You can press the ▲ button to query the last 5 fault records (E1-E5). The display will indicate:
- ">U" for overvoltage události.
- "<U" for undervoltage události.
8.2 Phase Sequence Error
If the LCD displays "ABC" character, it indicates a phase sequence error. To correct this, arbitrarily reverse any two of the three phase lines (L1, L2, L3) at the input.
9. Údržba
- Udržujte zařízení čisté a bez prachu a vlhkosti.
- Pravidelně kontrolujte těsnost kabelových spojů a známky opotřebení nebo poškození.
- Do not attempt to repair the device yourself. Refer to qualified personnel for service.
10. Záruka a podpora
For technical support, inquiries, or warranty claims, please contact the distributor:
Distributor: XNY INTERNATIONAL LIMITED
Adresa: Room 20A, Kiu Fu Commercial Building, 300 Lockhart Road, Wanchai, Hong Kong.
tel: 0086
Fax: 0086 577 89736991
WhatsApp: 0086 1565857 3377
Wechat: sinotimer
Skype: sinotimer
Web: www.sinotimer.com
E-mail: info@sinotimer.com