CREATE Wind Clear Rattan User Manual

Thank you for choosing our ceiling fan. Before using the appliance, and to ensure the best use, carefully read these instructions.
The safety precautions enclosed herein reduce the risk of death, injury and electrical shock when correctly adhered to. Keep the manual in a safe place for future reference, along with the completed warranty card, purchase receipt and package. If applicable, pass these instructions on to the next owner of the appliance. Always follow basic safety precautions and accident-prevention measures when using an electrical appliance. We assume no liability for customer failing to comply with these requirements.
LOCATION AND INSTALLATION REQUIREMENTS
MECHANIC TIPS
- According to safety regulations, the lowest point of the fan blade must be at least 2.3m (7 feet) from the floor.
- Please make sure the chosen location will not allow the rotating fan blades to come into contact with any objects.
- Ensure ceiling joists are sound and are large and strong enough to support the weight of the fan.
- To reduce the risk of fire, electric shock or personal injury, ensure that the fan mounting bracket is attached directly to the building structure. Do not mount to an outlet box.
- The mounting bracket must be firmly screwed to a load bearing structure, e.g. a concrete ceiling, steel structure or timber frame. If a timber frame is added, it must be securely nailed or screwed between two beams.
- To reduce risk of personal injury and property damage, do not bend or damage the downrod or the fan blades when handling or installing them. If you notice any product imperfections, please contact our after-sales service before proceeding to install the fan.
- Make sure the ceiling fan is securely fastened to the ceiling. All set screws must be checked and re-tightened where necessary before fan operation.
ELECTRICAL TIPS
- Turn off the power before performing any work on the ceiling fan and turn off the power breaker. To avoid possible electrical shock, check that the power is turned off at the fuse box or circuit breaker panel before wiring.
- The fan, mounting bracket and lighting equipment must be connected to a ground. Check that all splices are well insulated.
- Check and confirm that all connections are correct and secure. Once all electrical connections have been made, store all cables securely.
- Do not attempt to control this fan from a wall switch or remote control that is not approved by the manufacturer for use with the fan. Do not use a solid state controller. Use of a non-approved wall switch or remote control will void your warranty.
- Do not connect the ceiling fan to a dimmer switch.
SECURITY INSTRUCTIONS
Before using any electrical device, carefully read the basic safety measures:
- This appliance is not intended for use by persons with physical, sen- sory or mental disabilities, or by persons with a lack of experience and knowledge, unless they are supervised or have received instruc- tions regarding its safe use and understand the potential hazards as- sociated with it.
- Children do not recognize the dangers associated with operating a ceiling fan. Keep children away from ceiling fans.
- Do not expose the ceiling fan to rain or moisture. Do not operate the ceiling fan outdoors or with wet hands.
- Use only CREATE replacement parts.
- To reduce the risk of bodily injury, attach the fan directly to the supporting structure of the building following these instructions and use only the supplied hardware.
- To avoid possible electrical shock, before installing the fan, disconnect power by turning off the circuit breakers at the outlet box and the associated wall switch location. If you cannot lock the circuit breakers in the off position, place a prominent notice, such as a tag, on the service panel.
- To reduce the risk of bodily injury, do not bend the blade mounting system when installing, balancing, or cleaning the fan. Never insert foreign objects between the rotating fan blades.
- To reduce the risk of fire, or motor damage, do not use a solid state speed control with this fan. Use only CREATE speed controls.
Note: Important safety precautions and instructions in this manual are not intended to cover all conditions and situations that may occur.
When installing and operating this fan, common sense and caution are necessary.
PARTS LIST

Rosette

Bar

Bar of extension

Trim

Support mounting

Connection panel

Decorative lamp shade

Light plate

Tulip

Fan body

Remote control & Driver

Screws
REMOTE CONTROL

- Light
- ON/OFF button
- Timer
- Color temperature control
- Fan intensity control
- Reverse function
- Sound off button
- Batteries (2 x AAA)
Controller pairing
- Turn off the main light switch in the room where you have installed your fan for at least 10 seconds.
- Turn the switch on and you will hear a beep, within 3 seconds, press and hold the on/off button until you hear a beep.
- If the pairing process is unsuccessful, repeat the above steps again after turning off the wall switch for at least 1 minute.
LIGHT
Turns the fan light on and off regardless of whether the fan is running or not.
ON/OFF
Turns the fan on or off completely, regardless of whether it has the light on or off.
TIMER
Schedule automatic shutdown by choosing from the available options.
REVERSE FUNCTION
COLOUR TEMPERATURE
Toggles between the three types of available light colour temperatures (warm, neutral, and cool).
FAN INTENSITY
Increase or decrease the rotation speed of the fan blades.
DISABLE SOUND
By pressing the sound off button you can silence the sounds that the fan makes when you press any key on the remote control.
Change the direction of rotation of the fan blades. The winter function (turn to the right) forces the hot air accumulated in the ceiling downwards and the summer function (turn to the left) generates a breeze that cools the environment.
INSTALLATION INSTRUCTIONS
- Mark the correct position of the holes and fix the ceiling bracket using the screws with metal anchors or screws and washers appropriate to the type of ceiling chosen.
- Check the correct installation of the bracket before hanging the fan. This plate must support the entire weight of the fan.
INSTALLATION PREPARATION
- To avoid personal injury and injury, make sure that the place where you are going to hang the fan allows the blades to be 2.3 m or more from the ground and 76 cm from the nearest wall or obstacle.
- Make sure the junction box is adequately fastened to the building structure and can support the full weight of the fan.

INSTALLING THE MOUNTING BRACKET
Before installing the mounting bracket you should check the ceiling where the fan is to be installed and check if it is suitable for it.

Concrete ceiling
Drill 2 holes with an 8mm drill bit, according to the length of the expansion bolts.
Next, fix the mounting bracket to the ceiling with the screws.

Wood roof
Attach the mounting bracket to the wood ceiling with 4 minimum 7mm thick screws.
Do not fix the mounting bracket directly on ceilings less than 10mm to avoid the risk of the screw loosening and coming out.
NOTE: This fan can also be installed in a false ceiling, for this you must use fixing screws with a spring lever (not included).
DOWNROD INSTALLATION
- Choose the suspension bar that best suits your situation.
- Remove the bar bolt, removing the pin, and pass the canopy (roof trim) and the engine canopy through the suspension bar. Next, route the fan motor cables through the inside of the suspension bar. Tighten the suspension bar to the engine and insert the bolt and pin.
Standard mounting

Standard mounting hangs from the ceiling by a downrod.
Angle mounting

Angled mounting recommended for a vaulted or angled ceiling.
This fan can be installed on both a regular and vaulted ceiling, and can extend the hanging length with the longer hanging rod (supplied). To install the hanger bar you will need the following tools: a screwdriver, flat head screwdriver, adjustable pliers or wrench, step ladder, wire cutters, and electrical tape.
CHOICE OF FAN HEIGHT
- Choose the suspension bar that best suits your situation.
- Remove the bolt from the bar by removing the pin and thread the canopy (roof trim) and motor canopy through the hanger bar. Next, route the fan motor wires through the inside of the hanger bar. Fit the hanger bar to the engine and insert the bolt and cotter pin.
SUSPENSION SYSTEM INSTALLATION
- Take out the pin from the bottom of the fan body by removing the cliq R.

- Thread the cable through the bar, canopy, and trim, then seat the bar into the fan body and rotate until the holes in the bar align with the holes in the fan body.

- Finally insert the pin through the holes and fix it with the cliq R on the other side.

- Place the down tube with hanger ball on the mounting bracket, rotate the motor assembly until the mounting bracket check tab has dropped into the hanger ball registration slot and is seated firmly.

- Lift the canopy up to the ceiling to cover the mounting bracket (make sure the canopy sits on the two screws on the bracket), rotate the canopy to make sure the head of the screw is at the end of the holes, and finally tighten the screws. screws until secure.
INSTALLATION OF THE TRIM AND LIGHT PLATE
- Fit the trim by aligning the holes with the holes in the engine. Use three screws to attach it to the engine body. Make sure it is securely fastened.

- Remove the 4 screws from the centre of the fan body. Screw on the connection panel by aligning the holes with the holes in the motor. Leave the blue and white wires coming out of the centre hole.

PLACEMENT OF THE LIGHT PANEL


Connect the cables from the connection board to those from the LED panel. The LED panel is magnetized so it attaches to the connection board by simply putting both pieces together.
Note: While installing or removing the LED board, be careful not to touch the insulating tabs. Do not overtighten the screws or thread them too quickly as this could cause damage to the insulating tabs.
TULIP FIXING


Make sure the slot on the tulip is in the same line as the slot on the fan body, then rotate the shade slightly clockwise until it is tight and secure.
CHECK THE INSTALLATION
- Check the correct operation of the ceiling fan, checking that there is no strange movement or misalignment in any part of the fan.
- In the event that some type of buzzing/vibration can be seen, you can proceed to adjust the blades with the balancing kit.
- In this kit you have self-adhesive weights and clips in the form of “u”.
BLADE BALANCING KIT
Your ceiling fan may have blade balance problems when operating due to irregularities in the blades or brackets. In addition, incorrect mounting of the system or twisted bearings could cause additional problems.
To solve these problems you must perform a dynamic balance using the provided balance kit.
Follow the procedure below:
- Turn on the fan and set the speed at which the most sway is created (usually occurs at the highest speed).
- Turn off the fan. Select a blade and place the balance clip, halfway between the bracket and the tip, on the back edge of the blade.
- Turn on the fan. Wait to see if the rocking has improved or worsened. Turn off the fan again and place the clip on another blade to recheck. Repeat this process with all the blades and see which one has improved the most.
- Place the clip on the blade that has improved the most. Move it in or out of the blade and start the fan to find the best position where the clip offers the most swing improvement.
- Then remove the clip and install a balance weight on top of the blade on the center line near the point where the clip was placed. Use a knife or blade if necessary to separate the weights.
Watch out: Stand at a safe distance from the blades. If the clip has not been properly secured, for any reason, you could be injured.
CONNECTION TO THE APP
* Only for models with Wi-Fi
The CREATE app is available for both Android and iOS (search for the app on Google Play or App Store or scan the QR code below). There may be additional costs depending on the provider.
This device is used through your home network. As an essential requirement, you must have a Wi-Fi network always connected to your 2.4 Gh router and the free CREATE application.
(Internet providers currently offer both 5Gh and 2.4Gh simultaneously.)
We recommend that you disconnect the appliance from the mains when you are away from home to prevent it from accidentally starting up while you are away.
HOW TO CONNECT TO THE APP
- Install the CREATE app and create a user account.
- Set a login password and log in to the app.
- Click “Add Device” (+) and then click the category for the ceiling fan.
- On the remote control, press and hold the 1H and 4H buttons for about 5 seconds until you hear a beep.
- Next, click “Confirm”.
- Enter your Wi-Fi network password and confirm.
- While connecting, make sure your router, mobile phone and device are as close as possible. Finally, the ceiling fan will be successfully added to your CREATE application.
In compliance with Directives: 2012/19/EU and 2015/863/EU on the restriction of the use of dangerous substances in electric and electronic equipment as well as their waste disposal. The symbol with the crossed dustbin shown on the package indicates that the product at the end of its service life shall be collected as separate waste. Therefore, any products that have reached the end of their useful life must be given to waste disposal centres specializing in separate collection of waste electrical and electronic equipment, or given back to the retailer at the time of purchasing new similar equipment, on a one for one basis. The adequate separate collection for the subsequent start-up of the equipment sent to be recycled, treated and disposed of in an environmentally compatible way contributes to preventing possible negative effects on the environment and health and optimises the recycling and reuse of components making up the apparatus. Abusive disposal of the product by the user involves application of the administrative sanctions according to the laws.

Documents / Resources
![]() | Wind Clear Rattan |
![]() | Wind Clear Rattan |
References
- User Manualmanual.tools