Dual Tech Single Pole 120/277 VAC Wall
Switch Occupancy Sensor
(Neutral Required)
Typical Applications
Private Offices • Small Conference Rooms • Lunch/Break Rooms • Small Classrooms • Small Restrooms (1-2 stalls) • Small Lounges • Small Waiting Rooms • Small Closets • Small Storage Areas

Interactive Menu

  • Order Information page 2
  • Additional Resources page 2
  • Wiring Diagrams page 3
  • Product Warranty

Product FeaturesCOOPER Lighting Solutions ONW D 1001 Wall Switch Sensor - Symbol 1Product CertificationCOOPER Lighting Solutions ONW D 1001 Wall Switch Sensor - Features

 

Overview

The Dual Technology Single Level Occupancy Sensing Wall Switch is a motion sensing lighting control and conventional wall switch all-in-one that is used for energy savings and convenience.
The ONW-D-1001-MV-N combines Ultrasonic and Passive Infrared (PIR) sensor technologies to monitor a room for occupancy to deliver maximum energy savings and ensure the greatest sensitivity and coverage for tough applications without the threat of false triggers. PIR is used to turn the lights ON and then either or both technologies are used to keep the lights ON. In Automatic On Mode, the lights turn ON when a person enters the room. In Manual On Mode, the lights are turned ON by pressing the universally recognized light icon pushbutton. The sensor includes self-adaptive technology that continuously self-adjusts sensitivity and time delay in real-time, maximizing the potential energy savings that are available in the particular application. The EcoMeter provides a visual indicator of energy usage, increasing end user awareness and reminding individuals to take control of their lighting to maximize energy savings.

Top Product Features

  • Air-gap switch ensures no leakage current to load
  • Selectable built-in light level sensor
  • NEMA WD7 Guide robotic method utilized to verify coverage patterns

Order Information

SAMPLE ORDER NUMBER: ONW-D-1001-MV-N-W One single gang wallplate included.
COOPER Lighting Solutions ONW D 1001 Wall Switch Sensor - Catalog Number
Catalog Number

Catalog Number  Ratings  Coverage  Voltage  Color
ONW-D-1001-MV-N- * (*-W, V, LA, G, B, R) Incandescent: 0-800W @ 120V
Fluorescent: 0-1200W @ 120V
Fluorescent: 0-2700W @ 277V
Max Load/Relay
180°; 1000 sq. ft. 120/277 VAC, 50/60 Hz W=White, V=Ivory, LA=Light Almond, G=Gray, B=Black, R=Red
Notes Not all colors are available in stock and some color options may have extended lead times.

Product Specifications

Technology
• Passive Infrared (PIR) and Ultrasonic (US) technology
Mechanical
Mounting Plate/Strap Dimensions: 4.195” H x 1.732” W (106.55mm x 44mm)
Mounting Plate/Strap Dimensions: ONW-D-1001-347: 4.35” H x 1.732” W (110.49mm x 44mm)
Product Housing Dimensions: 2.618” H x 1.752” W x 1.9” D (66.5mm x 44.5mm x 48.26mm)
Environment:

  • Operating temperature: 32°F to 104°F (0°C to 40°C)
  • Relative humidity operating: 20% to 90% non-condensing
  • For indoor use only

Housing: Durable, injection molded housing. ABS resin complies with UL 94V-0
Mounting: Fits in a standard 3.5” deep back box Can be mounted in multiple gang back box. Refer to NEC box calculation for properly sized mounting box Electrical
Electrical ratings (per relay):

  • 120 VAC
  • Incandescent / Tungsten max load: 6.7 amps, 800W, 50/60 Hz
  • Fluorescent / Ballast max load: 10 amps, 1200W, 50/60 Hz
  • Motor Load: 1/4 HP @ 125 VAC
  • 230/277VAC
  • Fluorescent / Ballast max load: 9.8 amps, 2700W, 50/60 Hz

Ballast compatibilty:

  • Magnetic and Electronic ballasts

Hardware Specifications
LED Indicators:

  • Red LED = PIR detection
  • LED = Ultrasonic detection
  • Green LED = Acts as EcoMeter or nightlight locator

Controls and Performance
Time delays:

  • Self adjusting 15 seconds/test (10 min. Auto)
  • Selectable 5, 15, 30 minutes

Coverage:

  • Major motion: 36’ x 30’
  • Minor motion: 20’ x 16’

Light sensing level:

  • 0 to 200 foot candles

Standards/Ratings

  • cULus Listed
  • FCC Compliant
  • RoHS Compliant

Warning

  • This product is not intended to be used in applications involving the use of ammonia-based or VOC cleaners.
  • Use of ammonia-based or VOC cleaners on this device must be avoided.
    Prolonged use may cause loss of integrity and expose electrified components.
    If this occurs, turn OFF power to the unit and replace.
  • For detailed cleaning guidelines please refer to: Controls Care and Maintenance instructions at the end of this document.

Warranty
Five year warranty standard

Dimensional and Mounting Details COOPER Lighting Solutions ONW D 1001 Wall Switch Sensor - DimensionalWiring Diagrams
Single Level Switching – Single CircuitCOOPER Lighting Solutions ONW D 1001 Wall Switch Sensor - Single CircuitScale or Mounting Height

COOPER Lighting Solutions ONW D 1001 Wall Switch Sensor - HeightThree-way wiring diagram: Lights will turn OFF automatically when sensor that detected motion last, times out.COOPER Lighting Solutions ONW D 1001 Wall Switch Sensor - TRAVELER

Controls

COOPER Lighting Solutions ONW D 1001 Wall Switch Sensor - Controls

Time Delay Activation Not Used PIR Sensitivity Walk-Through Mode EcoMeter Override Not Used Maintain Lights On Not Used
DIP Switch 1 2 Relay 1 4 5 6 7 8 9 10 11 12
3
Auto* Auto Full Disable Enable Disable Either
5 Minutes Manual 50% Enable Disable Enable Both
15 Minutes
30 Minutes
*Self-Adjusts to 10 min. user mode COOPER Lighting Solutions ONW D 1001 Wall Switch Sensor - Time Dela

Field of ViewCOOPER Lighting Solutions ONW D 1001 Wall Switch Sensor - Field of View

Minor Motion, IR COOPER Lighting Solutions ONW D 1001 Wall Switch Sensor - Motion
Major Motion, IR COOPER Lighting Solutions ONW D 1001 Wall Switch Sensor - Major
Minor Motion, Ultrasonic COOPER Lighting Solutions ONW D 1001 Wall Switch Sensor - Ultrasonic
Major Motion, Ultrasonic COOPER Lighting Solutions ONW D 1001 Wall Switch Sensor - Ultrasonic 1

Maximum coverage area may vary somewhat according to room shape and the presence of obstacles.

Controls Care & Maintenance

Cooper Lighting Solutions

COOPER Lighting Solutions ONW D 1001 Wall Switch Sensor - Cooper Lighting

Cooper Lighting Solutions has developed recommended guidelines for cleaning our products that will not impact the operation or finish of the product.
Recommended cleaning tips:

  • Never spray any fluids directly into the device.
  • Use of ammonia-based or VOC cleaners on this device must be avoided. Prolonged use may cause loss of integrity and expose electrified components. If this occurs, turn OFF power to the unit  and replace.
  • Use a damp rag or single-use wipe to avoid excess liquid penetrating the device. Be sure to wipe up remaining excess liquid after cleaning.
  • Ensure the cleaning agent used does not have harsh chemicals such as bleach, ammonia, highly alkaline or concentrated acids (such as hydrochloric acid that can be found inhousehold cleaners such as toilet bowl cleaners, bathroom tile and porcelain  leaners) as they could damage the device, causing them to become brittle and discolored.
  • Cooper Lighting Solutions recommends the use of a mild liquid detergent and water to clean the devices. Single use wipes (e.g. Lysol brand or equivalent) are acceptable to use for cleaning the devices, however the single-use wipes cannot contain bleach, ammonia, highly alkaline or concentrated acids.

COOPER Lighting Solutions ONW D 1001 Wall Switch Sensor - cleaning warning - 1 WARNING
This product is not intended for use in applications involving the use of ammonia-based or VOC cleaners. Prolonged use may cause loss of integrity and expose electrified components. If this occurs, turn OFF power to the unit and replace.

Recommended cleaning instructions:

  • Never spray any fluids directly into the device.
  • Apply the mild liquid detergent to a damp cloth or paper towel. Single use wipes (e.g. Lysol brand or equivalent) are acceptable to use for cleaning the devices, however single-use wipes cannot contain bleach, ammonia, highly alkaline or concentrated acids.
  • If excess liquid is present, remove by wringing out the cloth or paper towel to avoid liquid penetration into the device.
  • Clean the Cooper Lighting Solutions device by wiping over the surface with the damp cloth.
  • Remove an excess liquid remaining on the device with a dry cloth or paper towel.

Cooper Lighting Solutions
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.cooperlighting.com
For service or technical assistance:
1-800-553-3879
Canada Sales
5925 McLaughlin Road
Mississauga, Ontario L5R 1B8
P: 905-501-3000
F: 905-501-3172
© 2024 Cooper Lighting Solutions
All Rights Reserved.
Product availability, specifications, and compliances are subject to change without notice.
SA50317022
April 2024

COOPER Lighting Solutions Logo

Documents / Resources

COOPER Lighting Solutions ONW-D-1001 Wall Switch Sensor [pdf] Owner's Manual
ONW-D-1001, ONW-D-1001 Wall Switch Sensor, Wall Switch Sensor, Switch Sensor, Sensor

References

Leave a comment

Your email address will not be published. Required fields are marked *