Our Portable Large Area Loop is an all-in-one fully portable hearing loop, ideal as a temporary solution or for use in multiple venues. It has a built in hearing loop driver, a 2 channel receiver and an auxiliary input. The receiving module is license-free and generally approved for operation in EU and EFTA countries.
Features
- Compact case
- 2 channel receiver
- Efficient power utilisation
- Continuous self-testing
- Accurate, lockable, front panel-mounted controls
- Padded pocket to house accessories
Standards
- BS EN 55103-1: 2009 (EMC emissions)
- BS EN 55103-2: 2009 (EMC immunity)
- FCC class “B” EMC (emissions)
- ICES-003
- IEC 60118-4 (in correct installations)
- IEC 62489-1
Physical Data
Dimensions |
Height – 254mm (10”) Width – 540mm (21.25”) Length – 368mm (14.5”) |
Weight (boxed) |
PLALS-V / PLALS-V15:
13.5kg (29.76lbs) |
PLALS-V22: 15.76kg (34.7lbs) | |
Construction |
Mild Steel |
ABS Plastic | |
Finish | Black Powder Coated |
Applications
Suitable for medium-sized facilities, such as:
- Meeting and conference rooms
- Lecture halls
- Places of worship
- Ideal as a temporary solution for:
- Events
- Rooms where a permanent installation is not achievable
- Traveling instructors or public speakers
Components
- V7, V15 or V22 [-UK/EU/AUS/USJ]
- Power supply [PS-55-01]
- Rack mount bracket [MBR]
- 30m copper loop wire reel [RL-TAPE]
- Carry case and fixings with a built-in rack [CASE-19-2U-01]
- 2-channel wireless microphone transmitter with belt pack [IL-AC-WM-LT-00]
- 2 x Lapel microphones
- Handheld microphone [IL-AC-WM-HT-00]
- Fixings, padding and connectors
V7 Technical Data
Power Supply | 30W 14Vdc 2.14A via External PSU (PS-55)
Class 6 External PSU (100V-240V AC 50Hz-60Hz) |
|
Inputs |
1 X Balanced Line Level (3 Pin Euro-Block) or
1 X Balanced Line Level (XLR) [optimized for -10dBV to 0dBv] |
|
1 X Mic Level (12V phantom power via 680W) [optimised for levels above -45dBv] | ||
1 X DC Input | ||
Outputs | 1 X Loop Output (5.08mm Euro-Block) | |
Loop Output Characteristics |
Voltage | 7.5Vrms (21.21Vpk-pk) @ 5Arms (14.14Apk-pk)* |
Current | 5Arms (14.14Apk-pk) up to 300 seconds* | |
Loop Connector | 5.08mm Euro-block | |
Audio System |
Frequency Response | 80Hz to 9kHz |
Distortion | THD+N <1% (-40dB) | |
AGC | Peak detecting | |
HF Comp | 7 optimised stages | |
Display & Controls |
Display | LED Backlit LCD display |
Control | Single rotary control | |
Fault Monitoring and Protection |
Main Display | Open circuit loop (DCR measurement) |
Loop ground fault | ||
Front Panel LED | Output voltage clipping | |
Cooling | Internal heatsink with thermal protection |
V15 Technical Data
Power Supply | 100W 24Vdc 4.17A via External PSU (PS-60)
Class 6 External PSU (100V-240V AC 50Hz-60Hz) |
|
Inputs |
1 X Balanced Line Level (3 Pin Euro-Block) or
1 X Balanced Line Level (XLR) [optimised for -10dBV to 0dBv] |
|
1 X Mic Level (12V phantom power via 680W) [optimised for levels above -45dBv] | ||
1 X DC Input | ||
Outputs | 1 X Loop Output (5.08mm Euro-Block) | |
Loop Output Characteristics |
Voltage | 15Vrms (42.3Vpk-pk) @ 5Arms (14.14Apk-pk)* |
Current | 5Arms (14.14Apk-pk) up to 300 seconds* | |
Loop Connector | 5.08mm Euro-block | |
Audio System |
Frequency Response | 80Hz to 9kHz |
Distortion | THD+N <1% (-40dB) | |
AGC | Switchable (ON/OFF) | |
HF Comp | 7 optimised stages | |
Acoustic Time Delay | 10ms to 70ms adjustable in 1ms steps | |
Display & Controls |
Display | LED Backlit LCD display |
Control | Single rotary control | |
Fault Monitoring and Protection |
Main Display |
Open circuit loop (DCR measurement) |
Loop ground fault | ||
Front Panel LED | Output voltage clipping | |
Cooling | Internal heatsink with thermal protection |
V22 Technical Data
Power (IEC Connection) |
Voltage | 100V-120V /200V-240V AC (Universal auto switching) | |
Power | 175W | ||
Frequency | 50Hz-60Hz | ||
Inputs |
Input A / Isolated |
Line | 3.5mm Euro-block [optimised for -10dBV to 0dBv] |
100V | 100V Line Input (Transformer isolated) 3.5mm Euroblock | ||
MP3 | 3.5mm Euroblock [Transformer Isolated, optimised for -10dBV to 0dBv] | ||
Input B | Universal | Input B Line/Mic. (12V phantom power via 680W) [optimised for levels > -45dBv to -10dBv] 3.5mm Euroblock | |
Loop Outputs |
Output Voltage | 1 x 22Vrms (62.04Vpk-pk) @ 12Arms (33.84Apk-pk)* | |
Output Current | 1 x 12Arms (33.84Apk-pk) up to 300 seconds | ||
Loop Connector | 1 x 4 Way 5.08mm Euro-block | ||
Line Output |
Output Voltage | 1 – 2Vrms | |
Connector | 1 x 3.5mm Euroblock | ||
Audio System |
Frequency Response | 80Hz to 9kHz | |
Distortion | THD+N <1% (-40dB) | ||
Automatic Gain Control | Switchable (Peak detecting) on or off | ||
High Pass Filter | For removal of low frequency noise | ||
High Frequency Comp. | 7 DSP controlled, optimised stages | ||
Acoustic Time Delay | 10ms to 70ms adjustable in 1ms steps | ||
Display | LED backlit LCD display with backlight time-out | ||
Control | Single rotary push control | ||
Front Panel LED | Output voltage clipping | ||
Fault Monitoring / Protection | Temperature, fan speed, PSU fault, loop open, loop impedance error |
- Note 1: Z=1.83Ω (162uH +0.838Ω @ 1.6kHz), Note 2: < 1% (-40dB) distortion, Note 3: The minimum loop resistance (DCR) is 0.25Ω
IL-AC-WM-2C-LT Technical Data
Power Supply | 12-18Vdc, 500mA |
Carrier Frequencies | 863 – 865MHz |
Channels | 81 tuneable UHF frequencies |
Signal to Noise Ratio | >105dB |
THD | <0.5% @ 1KHz |
Frequency Response | 50Hz – 18kHz ±1 dB |
Image Rejection | >85dB |
Connectors |
DC in |
2 x XLRM | |
6.3mm jack | |
2 x BNC antenna | |
Output Impedance | 2.2K W |
Output Level | 400mV (balanced), 200mV (unbalanced) |
IL-AC-WM-HT-00 Technical Data
Carrier Frequency Range | 863.1 – 864.9MHz |
S/N Ratio | >105dB |
Power Supply | 2 x AA batteries |
RL-TAPE Conductor Data
Composition | Copper 99.5% (minimum) |
Density | 8.9g/cm³ |
Melting Point | 1083°C |
Electrical conductivity | 58m/ohm mm² at 20°C (100%IACS) |
Electrical resistance | 0.01741 ohm mm²/m at 20°C |
Hardness | 50/60 HV |
Copper section |
RL-TAPE-10 – 0.5mm² RL-TAPE-12.5 – 1.25mm² RL-TAPE-25 – 2.5mm² |