COMMAND LIGHT LogoTFB-V5 Traffic Flow Boards
User Guide
COMMAND LIGHT TFB V5 Traffic Flow BoardsRevised 7/27/22
This guide supersedes all previous versions
MODEL COVERED:V5

TFB-V5 Traffic Flow Boards

THANK YOU
Please allow us to express a simple thank you for investing in a COMMAND LIGHT product. As a company we are dedicated to producing the very best and most versatile flood lighting package available. We take great pride in the quality of our work and hope that you will find many years of satisfaction from the use of this equipment.
Should you have any problems with your product please do not hesitate to contact us.
COMMAND LIGHT
3842 Redman Drive
Fort Collins, CO 80524
PHONE: 1-800-797-7974
FAX: 1-970-297-7099
WEB: www.CommandLight.com

HELD MÃBEL Base cabinet 150 cm wide - Icon 1 DANGER
PERSONAL RESPONSIBILITY CODE
The member companies of FEMSA that provide emergency response equipment and services want responders to know and understand the following:

  1. Firefighting and Emergency Response are inherently dangerous activities requiring proper training in their hazards and the use of extreme caution at all times.
  2. It is your responsibility to read and understand any user’s instructions, including purpose and limitations, provided with any piece of equipment you may be called upon to use.
  3. It is your responsibility to know that you have been properly trained in Firefighting and/or Emergency Response and in the use, precautions, and care of any equipment you may be called upon to use.
  4. It is your responsibility to be in proper physical condition and to maintain the personal skill level required to operate any equipment you may be called upon to use.
  5. It is your responsibility to know that your equipment is in operable condition and has been maintained in accordance with the manufacturer’s instructions.
  6. Failure to follow these guidelines may result in death, burns or other severe injury.

COMMAND LIGHT TFB V5 Traffic Flow Boards - LogoFire and Emergency Manufacturers and Services Association, Inc.
P0. Box 147, Lynnfield , MA 01940
www.FEMSA.org
Copyright 2006 FEMSA. All Rights Reserved

COMMAND LIGHT TFB V5 Traffic Flow Boards - Icon 1 Read this manual before installing or operating the Traffic Flow Board.
Save this guide for future reference.

Limited Warranty

Five Year
COMMAND LIGHT warrants that the equipment is free from defects in materials and workmanship when used and operated for a period of five years. The responsibility of COMMAND LIGHT under this limited warranty is limited to the repair and replacement of any parts found defective. Parts must be returned to COMMAND LIGHT at 3842 Redman Drive, Ft Collins, Colorado 80524 with transportation charges prepaid (C.O.D. shipments will not be accepted).
Prior to returning defective parts to COMMAND LIGHT , the original purchaser shall make a claim in writing to COMMAND LIGHT at the above address indicating the model number, serial number and type of defect. No parts or equipment will be received by COMMAND LIGHT for repair or replacement under this warranty without specific written authority from it in advance.
Any parts damaged by improper installation, overloading, abuse or accident of any type or cause are not covered by this warranty.
All equipment manufactured by us is tested before leaving our plant, and is shipped in good working order and condition. We therefore extend to the original purchasers the following Limited Warranty for the period of five years from the original date of purchase:

  1. This warranty does not apply to defects caused by accident, misuse, neglect, or wear and tear, nor can we be held responsible for incidental and consequential expense and loss, nor does this warranty apply to equipment where alterations have been executed without our knowledge or consent. These conditions are readily discernable when the equipment is returned to us for inspection.
  2. On all component parts not manufactured by COMMAND LIGHT , their warranty is to the extent that the manufacturer of such component warrants them to COMMAND LIGHT , if at all. Look in your local business telephone directory for the nearest repair station for the brand of parts you have or write to us for the address.
  3. If equipment received has been damaged in transit, a claim should be made against the carrier within three days, as we assume no responsibility for such damage.
  4. Any service other than our Authorized Service voids this warranty.
  5. This warranty is in lieu of and is intended to exclude all other warranties, express or implied, oral or written, including any warranties of MERCHANTIBILITY or FITNESS for a particular purpose.
  6. Travel time paid at a maximum of 50% and only if pre-approved.

Warranty/Service

COMMAND LIGHT products* come with a industry leading 5 year warranty against any defects in materials and workmanship when used and operated for a period of five years. If during this time period, you have any malfunctions not related to misuse, accident, neglect, or normal wear and tear, please take the following steps in order to have your light tower serviced under COMMAND LIGHT’s warranty.

  1. Contact us immediately for initial diagnosis and parts if needed at 800-797-7974 or info@commandlight.com
  2. You will need to have immediate access to light tower. This process can be done by individuals with little mechanical ability. (Involves pushing buttons and telling us what the light tower is doing or not doing)
  3. We then send parts (if needed) and have a technician dispatched (if needed) with a written work authorization number and a base amount of hours allotted to do repair
  4. We remain available for service support via phone, email, or video conference while technician completes repair, also to extend original time allotted if additional issue arise
  5. Mark repair as completed and validate the work authorization number for hours of labor / travel rates as agreed during diagnosis
  6. Finally, we will pay out or credit the invoice when we receive it from person/company performing the repair Please make contact with us as soon as problems arise in order to execute our warranty. We must have knowledge of the issue and a work order in place in order to pay or reimburse the department with the issue. Any unauthorized service
    voids this warranty. (No work is authorized until the call is made to us)

Contact Us Early – before any work is done – We’d love to help!
*Excludes light producing components (bulbs, lasers, LEDs) These components come with their own manufacturer warranty. Contact us and we can help get it.

Breakage or Damage During Shipment

The transportation company is fully responsible for all shipping damage and will resolve problems promptly if you handle it correctly. Please read these instructions carefully.
Examine the contents of all shipping cases. If you find any damage, call your transportation agent at once and have them make a description on the freight or express bill describing the damage and the number of pieces. Then contact us and we will send you the original bill of lading. Also promptly contact the transportation company and follow their procedure for filing a claim. Each company will have a unique procedure to follow.
Please note, we cannot and will not enter claims for damages. If we filed claim here, it would be sent to your local freight agent for verification and investigation. This time can be saved by you filing the claim directly. Every consignee is on the ground floor, in contact with the local agent who inspects the damaged goods, and thus, each claim can be given individual attention.

General Description and Specifications

COMMAND LIGHT TFB V5 Traffic Flow Boards - Icon 1
The COMMAND LIGHT TRAFFIC FLOW BOARD lift is designed to provide the means to elevate a high-intensity arrow board for emergency scene traffic direction with quick precision. As with any electromechanical device, take precautionary steps to assure safe operation.
Never operate the TRAFFIC FLOW BOARD near overhead power lines.
Power for the 12 VDC circuitry is provided by the emergency vehicle battery system. All mechanical actuation power is designed to be powered by the vehicles 12 VDC power supply. The umbilical corded control unit is powered via 12 VDC eliminating hazardous voltage levels within the hand held control box.
The COMMAND LIGHT TRAFFIC FLOW BOARD is manufactured to provide years of service with a minimum of maintenance.
Product Safety Precautions

  • Never operate the TRAFFIC FLOW BOARD near overhead high voltage power lines. The TRAFFIC FLOW BOARD is manufactured from electrically conductive materials.COMMAND LIGHT TFB V5 Traffic Flow Boards - Figure 1
  • Do not use the TRAFFIC FLOW BOARD for uses other than its’ intended purpose.
  • Do not move emergency vehicle with the lift extended.
    Visually verify that the lift is completely nested before moving vehicle.
  • Do not change lift position while people are located within its’ operating envelope. There are numerous pinch points that can cause serious bodily injury.
  • The TRAFFIC FLOW BOARD contains automatic reset circuit breakers. Disconnect power at the distribution panel before servicing the unit.
  • Do not use a high-pressure washer or subject the lift to high volumes of water when cleaning.
  • Never use the TRAFFIC FLOW BOARD as a lifting device or mobile arm.
  • Do not use a TRAFFIC FLOW BOARD that has been damaged or is not fully functional, including non-working indicator lamps.
  • Never hold any part of the TRAFFIC FLOW BOARD with a hand or foot while it is in motion.
  • The TRAFFIC FLOW BOARD has numerous pinch points. Keep loose clothing, hands and feet clear of moving parts.
  • Operating TRAFFIC FLOW BOARD on an inclination of 11 degrees or more can cause a malfunction or no function at all. It can also cause damage to the TRAFFIC  LOW BOARD itself, to the vehicle and to personnel.

COMMAND LIGHT TFB V5 Traffic Flow Boards - Icon 1

COMMAND LIGHT TFB V5 Traffic Flow Boards - Figure 2

Operation

Raising the TRAFFIC FLOW BOARD from the nested position:
Use the control box to raise the TRAFFIC FLOW BOARD to the maximum height. Control unit switches are of momentary action style and must be held in the “ON” position to activate the unit. Once motion has started, the switch may be released. Motion will proceed until max height is reached, the down switch is activated or the emergency stop button is pressed.
The TRAFFIC FLOW BOARD has an override system that prevents rotation of the board until it is at the maximum height.
Returning the TRAFFIC FLOW BOARD to the nested position:
The TRAFFIC FLOW BOARD is equipped with an auto-park function as a standard feature.
Holding the movement control switch in the down position for 1 second initiates auto-park.
Once motion has started, the switch may be released and motion will proceed until nested.
Auto-park can be initiated while the TRAFFIC FLOW BOARD is in any rotated position. The controller indicates a red light when the TRAFFIC FLOW BOARD is out
of nest, and a green light when the TRAFFIC FLOW BOARD is fully nested. Auto-park sequence is as follows:

  1. Arrow board rotates to the center position.
  2. Once the board is centered, rotation stops and the carriage retracts.
  3. Board is fully nested, red light on controller turns off, green light turns on.
    At any point, the auto-park sequence can be cancelled by pressing the motion control switch up or Emergency Stop Switch

COMMAND LIGHT TFB V5 Traffic Flow Boards - Figure 3

Lower Override
In the event of sensor, rotation motor, or auto-park failure, a backup override is programmed into the TRAFFIC FLOW BOARD to allow for nesting board. Rotate the board to center as best as able. This can be done by hand if rotation motor has failed, but take care to apply pressure slowly to prevent damage to components. While a helper holds the board to the center position, at the controller, hold the Motion Control Switch in the down position while also holding the Emergency Stop Switch. After 5 seconds of holding both switches, the board will retract. Motion can be stopped by releasing either switch. To re-initiate motion, hold both switches for 5 seconds again. Lower the board until it is nested enough for safe travel and able to be brought in for service.

Installation

The TRAFFIC FLOW BOARD must be installed by a designated installation facility by qualified personnel only. All safety precautions must be thoroughly understood before
installation. Please consult the factory for additional installation information assistance.
Installation Kit
Included with the TRAFFIC FLOW BOARD is an installation kit. Verify that the contents of the kit include the following items:

  1. Pre-wired control unit with pocket
    (1) Control box
  2. Cables (Both are hardwired to the relay box)
    (1) 20 conductor 22 gauge wire 50ft. (gray)
    (1) 2 conductor 6 gauge wire, 50ft. (black/red)

Tools Required
Drill
15/64”drill bit
1/8” drill bit
#4mm hex wrench
10mm wrench
½ wrench
COMMAND LIGHT TFB V5 Traffic Flow Boards - Icon 1 The TRAFFIC FLOW BOARD weighs approximately 150 pounds. Use mechanical assistance (such as crane or forklift) to position the TRAFFIC FLOW BOARD for installation. Use a sling to grasp the TRAFFIC FLOW BOARD . When routing the connecting electrical wires, take care to avoid sharp bends, hot components or other hazards to the wire.
The TRAFFIC FLOW BOARD is not designed to be operated in a raised position while the vehicle is in motion. The TRAFFIC FLOW BOARD includes warning circuit wiring to enable a warning device (located in the control holster).
Location Requirements
The TRAFFIC FLOW BOARD frame can be mounted on any location that is 12” x 43.5”.
The surface should be flat. A minimum depth of 43” is required.
Eight mounting bolt holes are required.
The control box should be mounted in an area shielded from the weather. Allow a minimum of 10” clearance above the control box mounting location to permit easy emoval of the hand controller.
MountingCOMMAND LIGHT TFB V5 Traffic Flow Boards - Icon 2
The TRAFFIC FLOW BOARD is packaged with lift brackets mounted to each side. These are only used for installation and will be removed before after installation is complete.COMMAND LIGHT TFB V5 Traffic Flow Boards - Figure 4 Attach any necessary lifting attachments to the unit. Lift and place the TRAFFIC FLOW BOARD into position above the installation pocket. Make sure to feed all cables through the installation pocket and access hole before lowering the TRAFFIC FLOW BOARD into place. Lower the TRAFFIC FLOW BOARD into place and confirm that the mounting brackets will sit flush on the exterior surface. Also confirm that all mounting bracket holes have a mounting surface beneath them. Remove any obstructions below the mounting surface such as headliners before drilling mounting holes. Drill 15/64” holes in the mounting surface using the mounting bracket holes as a template.
Use the foam insulating tape to surround the edge of the installation pocket to create a water-resistant seal. Remove any lifting straps and devices from the lift.
After the installation of the mounting brackets, remove the lifting brackets with a ½” wrench.
Locate and drill wire feed holes as necessary.
Control Box Holster Mounting
Using the pocket as a template, mark hole locations.
Drill 1/8” mounting holes. Drill any holes required to route the control wire from the control box holster to the TRAFFIC FLOW BOARD unit.
Electrical Wiring
Run the control wire from the TRAFFIC FLOW BOARD to the Control Box Holster.
Run the power wire from the vehicle 12VDC power source or generator to the TRAFFIC FLOW BOARD. A 15 Amp breaker is recommended for the TRAFFIC FLOW BOARD . Refer to wiring schematic to assist in identifying connections.
Warning Device Installation
The nest sensor can be used to activate a warning device when the light is extended. To connect such a device, determine whether it is activated when it receives 12 VDC or when it receives a path to ground. The connector for hooking up a warning device is located in the holster box that holds the control unit.

COMMAND LIGHT TFB V5 Traffic Flow Boards - Figure 5

Technical Specifications

Dimensions:

Height(Depth)  Length  Width 
Retracted
Extended
Recessed installation
26”
42”
26”
44”
44”
42 ½ ”
12”
12”
12” Minimum

Weight:
150 pounds
Wiring:

12 VDC 50 ft 6/2 cable
Control wiring 50 ft 22/20 cable

Command Light recommends using 6 gauge wire for input power.

Relay protection:

Electrical Cole-Hersee 3055 15 Amp

Current Draw:

Full load current draw 15 amps at 12VDC

Motor Duty Cycle:
(All motors thermally protected, specifications are to thermal relay trip):

Lift motor 1:3 (90 seconds maximum per 5 minute)
Rotation motor 1:3 (90 seconds maximum per 5 minute)

Motor Speed:

Carriage 0.5 inches per minute 5 seconds to full extension
Rotation 1.6 1250 RPM 15 seconds
Auto Park 20 seconds from full extension and at
350degree rotation position

Operation:

Angle of vehicle 10˚ maximum incline

Wind load:

Design maximum 75 mph
Maximum tested 85 mph

Specifications subject to change without notice.

COMMAND LIGHT TFB V5 Traffic Flow Boards - Figure 6

Exploded Views and Parts List:
Arrow Board

COMMAND LIGHT TFB V5 Traffic Flow Boards - Figure 7

PARTS UST
ITEM QTY PART NUMBER DESCRIPTION I
1 1 076-30045 BACK,LED BOARD,TFBVS
2 1 076-30046 ARRAY,ENCLOSURE,FRONT,TFBV
3 8 069-01004 GROMMET,GR-65PT,MARKER LAMP
4 8 069-01003 LAMP,MARKER,LED,PT-Y56A
5 6 069-01103 SCREW,BH,HEX,6x1x12,SS
6 4 065-10075 BRACKET,END,DIN,DN-EB35
7 2 069-01000 RAIL, DIN, SLOTTED, 7.5MM X 35MM 4 in.
8 1 065-10073 BLOCK,TERMINAL,DIN,DN-T10-WHITE
9 3 065-10072 BLOCK,TERMINAL,DIN,DN-T10-RED
10 1 065-10068 BLOCK,TERMINAL,DIN,DN-T10-BLUE
11 2 065-10071 BLOCK,TERMINAL,DIN,DN-T10-ORANGE
12 1 065-12831 LOCKNUT,NYLON,3/8 NPT,BLACK
13 1 076-29986 BRACKET,SENSOR TRIGGER,TFBV
14 4 034-10961 SCREW,PHP,10-24 UNCx0.375
15 2 034-10966 SCREW,PHP,10-24 UNCxO.75
16 2 034-10979 WASHER,LOCK,SPRING,REGULAR, #10, SS
17 2 034-13100 NUT,MS,HEX2,10-24UNC,SS
18 6 034-10981 NUT,NYLOCK, 10-24 UNC,SS
19 4 069-01116 SCREW,FHSH,M8x1.25×16
20 1 065-12883 STRAIN RELIEF,DOMED 90,SCR .16-.31,3/8 NPT,BLACK
21 2 065-10074 BLOCK,TERMINAL,DIN,DN-T10-YELLOW
22 2 034-10978 WASHER,LOCK,18-8SS,INTERNAL,#10

Control Array

COMMAND LIGHT TFB V5 Traffic Flow Boards - Figure 8

PARTS LIST
ITEM QTY PART NUMBER DESCRIPTION
1 1 076-30038 CARRIER,CONTROL ARRAY,TFBV
2 1 069-01000 RAIL, DIN, SLOTTED, 7.5MM X 35MM 16.75 in.
3 1 065-10055 RELAY,PROGRAMMABLE,10A,12-24VDC
4 3 065-10056 RELAY,MODULE,5A,12-24VDC
5 13 065-10071 BLOCK,TERMINAL,DIN,DN-T10.ORANGE
6 8 065-10068 BLOCK,TERMINAL,DIN,DN-T10-BLUE
7 6 065-10070 BLOCK,TERMINAL,DIN,DN-T10-GREEN
8 2 065-10072 BLOCK,TERMINAL,DIN,DN-T10-RED
9 2 065-10074 BLOCK,TERMINAL,DIN,DN-T10-YELLOW
10 3 065-10069 BLOCK,TERMINAL,DIN,DN-T10-BLACK
11 1 065-10073 BLOCK,TERMINAL,DIN,DN-T10-WHITE
12 2 065-10075 BRACKET,END,DIN,DN-EB35
13 7 069-01102 SCREW,BH,HEX,4×0.7×12,SS
14 1 065-10048 BREAKER, 12V 8A, SINGLE POLE
15 13 034-10947 WASHER,FLAT,SAE, #8, SS
16 2 065-13730 Socket, Single Pole, Relay
17 2 065-13738 RELAY, 12V, SINGLE POLE
18 7 034-13672 NUT,NYLOCK, 4-40 UNC,SS
19 1 034-10966 SCREW,PHP,10-24 UNCx0.75
20 1 034-13100 NUT,MS,HEX2,10-24UNC,SS
21 1 034-10981 NUT,NYLOCK, 10-24 UNC,SS
22 2 034-10978 WASHER,LOCK,18-8SS,INTERNAL,#10
23 1 069-01103 SCREW,BH,HEX,6x1x12,SS
24 2 065-10089 JUMPER, DIN RAIL TERM BLOCKS,5 POSITION
25 1 076-30039 COVER,CONTROL ARRAY,TFBV
26 1 065-10089 JUMPER, DIN RAIL TERM BLOCKS,4 POSITION
27 1 065-10089 JUMPER, DIN RAIL TERM BLOCKS,6 POSITION
28 1 065-10089 JUMPER, DIN RAIL TERM BLOCKS,3 POSITION
29 2 065-10089 JUMPER, DIN RAIL TERM BLOCKS,2 POSITION
31 2 034-10977 WASHER,FLAT,SAE, #10, SS
32 2 034-13678 WING NUT, 10-24, SS
35 1 069-01012 CABLE TRACK,W/BRACKETS,4 FT,TFBV2

Surround

COMMAND LIGHT TFB V5 Traffic Flow Boards - Figure 9

Surround: Parts List

PARTS LIST
ITEM QTY PART NUMBER DESCRIPTION
1 1 076-30043 COVER,FRONT,LOWER,TFBV5
2 1 076-30047 BASE,SURROUND,TFBV5
3 1 076-30048 SURROUND,FRAME,TFBVS
4 1 076-30049 COVER,FRONT,SURROUND,TFBV5
5 1 076-30075 PAN,INSTALLATION,LOWER,TFBV5
6 1 076-30044 COVER,ACCESS,CONTROL ARRAY,TFBV
7 2 076-30056 MOUNT,ANGLE,FRONT-REAR,TFBV5
8 2 076-30059 HANDLE,LIFT,DISPOSABLE,TFBV5
9 2 076-30079 MOUNT,ANGLE,2,STD,TFBVS-7
10 4 069-01120 SCREW,8H,HEX,8×1.25×20,SS
11 2 069-01116 SCREW,FHSH,M8x1.25×16
12 8 069-01115 SCREW,FHSH,M8x1.25×20
13 4 069-01106 SCREW,8H,HEX,Bx1.25×12,SS
14 18 069-01103 SCREW,BH,HEX,6x1x12,SS
15 4 069-01119 WASHER,LOCK,SPRING,REGULAR, M8, SS
16 4 069-01113 Nut, MS, MM8x1.25
17 8 069-01107 SCREW,BH,HEX,8×1.25×16,SS
18 2 STD HARDWARE-80 SCREW,PHP,10-24 UNCx2.5
19 4 034-10977 WASHER,FLAT,SAE, #10, SS
20 2 034-13100 NUT,MS,HEX2,10-24UNC,SS
21 1 065-12852 STRAIN RELIEF,DOMED,SCR .24-.47,1/2 NPT,BLACK
22 2 065-12875 STRAIN RELIEF,DOMED,RCR .08-.24,3/8 NPT,BLACK
23 1 065-12856 LOCKNUT,NYLON,1/2 NPT,BLACK
24 2 065-12831 LOCKNUT,NYLON,3/8 NPT,BLACK
25 1 076-30050 COVER,TOP,SURROUND,TFBV5

Carriage Assembly

COMMAND LIGHT TFB V5 Traffic Flow Boards - Figure 10

Carriage Assembly: Parts List

PARTS LIST
ITEM OTT PAID NUMBER OESOUPTICti
1 1 076-30012 CORRIAGEMON LIFT,711392
2 I 034-13079 ROLL P443/32 x 324.55
3 4 076-30011 MATE.SUPPORT KARING.D13V2
4 19 034-13695 DADRA/U.7,0S% 5/16-, SS
5 14 069-01006 WARINGA5300 Sealed
6 2 076-30010 SLOCK,TRAVERSE RAR.11482
7 4 069-01101 SCREW,011.MEX.10xI.5825.66
e 5 069-01120 SCREVOITIMEX,60.25,25,55
9 4 069-01111 SCREWOLHESE61.25,50,55
10 11 069-01113 MA. MS, tat 26
11 2 069-01013 FOOT.ULRGE.M12
12 2 6941124 /M. KS 14,41241.75
13 6 076-20985 SCREV4SPICS.5MCS M881.25830
14 6 076-30007 SPACER.9EARING,DINER.TX8V2
15 4 065.10057 SENSOR, PROOMITY, 90 DEGREE, APS4-1214-02
16 3 034.11147 SCREW,PNP.632 U1104.5
17 1 6901015 NOTOR,TRANSMOTEC.P1)54266-12-8644F
18 1 6901010 RALET.CONE.714v2
19 10 069-01102 SCREM0ILNEX4.A7412.65
20 1 7630037 COVER.ROTAI IC” MOTOIL71411
21 1 076-30031 SLIDE.ADJUSIEFLORIVE OELTIFEN2
22 1 076-30033 RelLEILOELT TE/8510/1,TF8V2
23 1 069-01129 0013.61-0A-DER.M041-25.12mm
24 3 069-01107 SCREINANIMEXA1.25×1455
25 1 069-01119 wASHERAACKDNUNG.REDRAIL 448, 5.6
I 076-30004 MCONTAOLLER,WINOLT19482
27 I 076-30003 ROMERMNOLICLER,TF812
28 t 69431110 SCREWOH.HEX,8.1 75‘45,65
29 10 069-01106 SCREWEIM.HEXAN 1 75412,65
30 2 076-30018 131.00c8EARING.SPINDLE,TRIV2
31 2 069-01009 Estilino, Ramm, Rout, F1416204, 1 ID
32 1 076-30019 SPINCLE.ROTATION,CARRIAGE,771392
33 1 7630027 PuLLET.CRNEILROTATION.T11192
34 I 034.11052 WASHER,RAT.FENDER. 5/16% SS
35 1 076-30040 KET.smou.nrev
1 076-29998 OWINELV/IRLI18V2
37 1 076-29997 CRAMP-SIC:PM LIOARD,IFBV2
38 1 076-29909 SPAM-00DM Rea 7PEN
39 1 026-29990 SPACER, CRADLE. FRONT, TEEN
eo 3 6941122 SCREWMIARNI.2644120,SS
42 3 034-11053 WASHER,LOOGSPRINOREO1U61. 5/16-, SS
43 1 6941117 SCREW,196111081.25:440
M 1 066-10001 SENSOR, FROONTY. STROME APS4-126-8.2
45 1 034-13696 SCREVIMP,6-32 UNO41.375
46 1 069-01002 MOTOR, MACON LIFT MOTOR 742-119,TF8V2
47 2 034.13692 SCREW,184,1/4-212.2.3/445
48 1 076-29980 MATE.MOTOR.W11401.TRIV
49 2 034-11021 5CREW,1414,1/4-2442.65
50 3 6941112 MA, NS, N41041.50
51 3 069-01100 SOO-W,BILHEY.,11241.920$5
52 1 034.11018 SCREMEM1,1/4-2041•1/4,SS
53 1 034-11116 NUT,NYLOOC,711I1L 1/4-20 RHEAS
54 1 016-29979 GEAR.INTEMAL.SKXLIFIN
55 1 076-29981 5P301..LIFT WINDLIT81/7,R2
56 1 076-39979 NATE.OUTER.WINCK7T8V
57 1 034-11033 NUT,NYWOL U4-20 UNC.SS
m 1 076-29907 °LOCK-SENSOR STOP.ITO V WOES
59 2 6941137 SCRON,DICS.SICS 046×145
60 4 6941103 SCREVCIRMIEX,M1x12.55
61 4 065-12365 CLO4P,L0014.86,S5
62 1 076-29996 SPADER.WIRE TRAOLTN3_V2
63 1 069-01109 SCREW,EINMEX8x1.25840,SS
64 2 076-30027A 10-32 UNE a 1/2 94 SO &NM SS
65 1 069-01008 SELT,HT045051415,ROTATION,IFBV
66 1 069-01011 STRAPMENCH,LIFT,TEBY
67 1 034.13681 WASNERJRAT,SAE, *6, SS

Carriage Frame

COMMAND LIGHT TFB V5 Traffic Flow Boards - Figure 11

Carriage Frame: Parts Lis

PARTS LIST
ITEM QTY PART NUMBER DESCRIPTION
1 1 076-30043 COVER,FRONT,LOWER,TFBVS
2 1 076-30047 BASE,SURROUND,TFBV5
3 1 076-30048 SURROUND,FRAME,TFBV5
4 1 076-30049 COVER,FRONT,SURROUND,TFBVS
5 1 076-30075 PAN,INSTALLATION,LOWER,TFBV5
6 1 076-30044 COVER,ACCESS,CONTROL ARRAY,TFBV
7 2 076-30056 MOUNT,ANGLE,FRONT-REAR,TFBV5
8 2 076-30059 HANDLE,LIFT,DISPOSABLE,TFBVS
9 2 076-30079 MOUNT,ANGLE,2,STD,TFBV5-7
10 4 069-01120 SCREW,BH,HEX,8×1.25×20,SS
11 2 069-01116 SCREW,FHSH,M8x1.25×16
12 8 069-01115 SCREW,FHSH,M8x1.25×20
13 4 069-01106 SCREW,BH,HEX,8×1.25×12,SS
14 18 069-01103 SCREW,BH,HEX,6x1x12,SS
15 4 069-01119 WASHER,LOCK,SPRING,REGULAR, M8, SS
16 4 069-01113 Nut, MS, MM8x1.25
17 8 069-01107 SCREW,BH,HEX,8×1.25×16,SS
18 2 STD HARDWARE-80 SCREW,PHP,10-24 UNCx2.5
19 4 034-10977 WASHER,FLAT,SAE, #10, SS
20 2 034-13100 NUT,MS,HEX2,10-24UNC,SS
21 1 065-12852 STRAIN RELIEF,DOMED,SCR .24-.47,1/2 NPT,BLACK
22 2 065-12875 STRAIN RELIEF,DOMED,RCR .08-.24,3/8 NPT,BLACK
23 1 065-12856 LOCKNUT,NYLON,1/2 NPT,BLACK
24 2 065-12831 LOCKNUT,NYLON,3/8 NPT,BLACK
25 1 076-30050 COVER,TOP,SURROUND,TFBV5

Wiring

COMMAND LIGHT TFB V5 Traffic Flow Boards - Figure 12

COMMAND LIGHT TFB V5 Traffic Flow Boards - Figure 13

COMMAND LIGHT LogoCommand Light PHONE: 1-800-797-7974
3842 Redman Drive FAX: 1-970-297-7099
Fort Collins, CO 80524
WEB: www.CommandLight.com

Documents / Resources

COMMAND LIGHT TFB-V5 Traffic Flow Boards [pdf] User Guide
TFB-V5 Traffic Flow Boards, TFB-V5, Traffic Flow Boards, Flow Boards

References

Leave a comment

Your email address will not be published. Required fields are marked *