COMMAND LIGHT LogoSHADOW SERIESCOMMAND LIGHT SL422D SHADOW Series Versatile Flood LightingEffective November 2022
This guide supersedes all previous versions
3842 Redman Drive
Fort Collins, CO 80524
MODEL COVERED:
SL422D SL442D

SL422D SHADOW Series Versatile Flood Lighting

THANK YOU
Please allow us to express a simple thank you for investing in a COMMAND LIGHT product.
As a company, we are dedicated to producing the very best and most versatile flood lighting package available. We take great pride in the quality of our work and hope that you will find many years of satisfaction from the use of this equipment.
Should you have any problems with your product please do not hesitate to contact us.\
DELL Command Power Manager Apps - icon 2 DANGER
PERSONAL RESPONSIBILITY CODE
The member companies of FEMSA that provide emergency response equipment and services want responders to know and understand the following:

  1. Firefighting and Emergency Response are inherently dangerous activities requiring proper training in their hazards and the use of extreme caution at all times.
  2. It is your responsibility to read and understand any user’s instructions, including purpose and limitations, provided with any piece of equipment you may be called upon to use.
  3. It is your responsibility to know that you have been properly trained in Firefighting and/or Emergency Response and in the use, precautions, and care of any equipment you may be called upon to use.
  4. It is your responsibility to be in proper physical condition and to maintain the personal skill level required to operate any equipment you may be called upon to use.
  5. It is your responsibility to know that your equipment is in operable condition and has been maintained in accordance with the manufacturer’s instructions.
  6. Failure to follow these guidelines may result in death, burns or other severe injury.
    COMMAND LIGHT Logo Sil Fire and Emergency Manufacturers and Services Association, Inc. P0. Box 147, Lynnfield , MA 01940 www.FEMSA.org
    Copyright 2006 FEMSA. All Rights Reserved

warning - 1 WARNING
Read this manual before installing or operating the
COMMAND LIGHT SHADOW
RTB . Save this guide for future reference.

COMMAND LIGHT 5 YEAR LIMITED WARRANTY

COMMAND LIGHT products* come with an industry leading 5-year warranty against any defects in materials and workmanship when used and operated for a period of five years. The responsibility of COMMAND LIGHT under this limited warranty is limited to the repair and replacement of parts found to be defective by COMMAND LIGHT.
Any parts damaged in shipping or by improper installation, overloading, abuse, or accident of any type or cause are not covered by this warranty. If equipment has been damaged in transit, a claim should be made against the carrier within three days, as we assume no responsibility for such damage.
If during this time period, you have any malfunctions not related to misuse, accident, neglect, or normal wear and tear, please take the following steps in order to have your light tower serviced under the COMMAND LIGHT warranty.

  1. Contact us immediately for initial diagnosis at info@commandlight.com or 800-797-7974; or if parts are needed contact parts@commandlight.com.
  2. You will need to have immediate access to the light tower and the serial number. This process can be done by individuals with little mechanical ability. (Involves pushing buttons and telling us what the light tower is doing or not doing)
  3. We then send parts (if needed) and have an authorized technician dispatched (if needed) with a written work authorization number and a base number of hours allotted to do repair. Hourly rates for service are to be determined at the time of authorization by COMMAND LIGHT, travel time is paid at a maximum of 50% of the authorized service rate.
  4. We remain available for service support via phone, email, or video conference while the technician completes the repair, also to extend the original time allotted if additional issues arise. Immediate support cannot be guaranteed unless a time is scheduled prior to service.
  5. Let us know when the repair is completed and reference the work authorization number. Email an invoice to info@commandlight.com or parts@commandlight.com. If you are unable to create an invoice email us for instructions for payment. Make sure any parts we have requested to be returned have been shipped back to the provided shipping address. If a return label is issued it must be used.
  6. Finally, we will pay by mailing a check or crediting the account of the person, department, or company doing the repair. Payments will not be made until all requested parts have been returned. Please contact us as soon as problems arise in order to execute our warranty. We must have knowledge of the issue and provide a work authorization in order to pay or reimburse labor or travel time. Any unauthorized service voids this warranty. No work is authorized until written consent is provided by COMMAND LIGHT. Contact Us Early — before any work is done — We’d love to help!
    *Excludes light producing components (bulbs, lasers, LEDs) These components may come with their own manufacturer warranty. Contact us and we can help get it.

Breakage or Damage During Shipment

The transportation company is fully responsible for all shipping damage and will resolve problems promptly if you handle it correctly. Please read these instructions carefully.
Examine the contents of all shipping cases. If you find any damage, call your transportation agent at once and have them make a description on the freight or express bill describing the damage and the number of pieces. Then contact us and we will send you the original bill of lading. Also promptly contact the transportation company and follow their procedure for filing a claim. Each company will have a unique procedure to follow.
Please note, we cannot and will not enter claims for damages. If we a filed claim here, it would be sent to your local freight agent for verification and investigation. This time can be saved by you filing the claim directly. Every consignee is on the ground floor, in contact with the local agent who inspects the damaged goods, and thus, each claim can be given individual attention.
Since our goods are packed to comply with the regulations of all railroad, truck, and express companies, we cannot allow deduction from any invoice because of any damage, however, be sure to file your claim promptly. Our goods are sold F.O.B. factory. We take receipt from the transportation company certifying that the goods were delivered to them in good order and our responsibility ceases.
It is seldom that any breakage or damage occurs in any of our shipments and in no case will the customer be out any expense if they follow the above instructions.
Be sure to keep all damaged goods subject to examination of the truck or express company inspector, who may call on you sometime later. These damaged goods, of course, will belong to them, and they will inform you what to do with them. If you dispose of these damaged goods, your claim may not be paid.
WARNING

Product Safety Precautions

[ Never operate the COMMAND LIGHT SHADOW RTB near overhead high voltage power lines. The  COMMAND LIGHT SHADOW RTB is manufactured from electrically conductive materials.COMMAND LIGHT SL422D SHADOW Series Versatile Flood Lighting - Icon COMMAND LIGHT SL422D SHADOW Series Versatile Flood Lighting - Icon 1 Do not use the COMMAND LIGHT SHADOW RTB for uses other than its intended purpose.
COMMAND LIGHT SL422D SHADOW Series Versatile Flood Lighting - Icon 1 Do not move emergency vehicle with the light extended. Visually verify that the light is completely nested before moving vehicle.
COMMAND LIGHT SL422D SHADOW Series Versatile Flood Lighting - Icon 1 Do not change light position while people are located within its operating envelope. There are numerous pinch points that can cause serious bodily injury.
COMMAND LIGHT SL422D SHADOW Series Versatile Flood Lighting - Icon 1 Do not use a high-pressure washer or subject the light to high volumes of water when cleaning.
COMMAND LIGHT SL422D SHADOW Series Versatile Flood Lighting - Icon 1  Never use the COMMAND LIGHT SHADOW RTB as a lifting device or mobile arm.
COMMAND LIGHT SL422D SHADOW Series Versatile Flood Lighting - Icon 1 Do not use a COMMAND LIGHT SHADOW RTB that has been damaged or is not fully functional, including non-working indicator lamps.
COMMAND LIGHT SL422D SHADOW Series Versatile Flood Lighting - Icon 1 Never hold any part of the COMMAND LIGHT SHADOW RTB with a hand or foot while it is in motion.
COMMAND LIGHT SL422D SHADOW Series Versatile Flood Lighting - Icon 1 The COMMAND LIGHT SHADOW RTB has numerous pinch points. Keep loose clothing, hands and feet clear of moving parts.

COMMAND LIGHT SL422D SHADOW Series Versatile Flood Lighting - Icon 2

General Description and Specifications

The SHADOW RTB is designed to provide high intensity emergency scene lighting with quick precision. As with any electromechanical device, take precautionary steps to ensure safe operation.

Model #  Description  Minimum Power Requirements
SL422D 2 x LED 50 Amps, 12 VDC
SL442D 4 x LED 90 Amps, 12 VDC

The vehicle provides power for the 12 VDC circuitry. A 15 Amp breaker is recommended.
The umbilical corded control unit is powered via 12 VDC eliminating hazardous voltage levels within the hand held control box.
The SHADOW RTB is manufactured to provide years of service with a minimum of maintenance.

Operation

Raising the light from the nested position
Using the control box, raise the lower stage. Control switches are of momentary action style and must be held in the “on” position to actuate the stages.
The SHADOW RTB has an override system that precludes rotation of the lamp tree until the lower stage has elevated approximately 16″ from the nested position. When the lower stage is below 16” the following conditions exist:

  • amp Tree is prevented from rotating.
  • All lights are turned off, including strobe light if equipped, regardless of light switch positions.
  • Prevents the lower stage from moving down if lamp tree is not centered.
    If the supply from the vehicle is marginal, position the SHADOW RTB before turning on lights.

Returning the light to the nested position
The KNIGHT 2 is equipped with an Autopark function as a standard feature. The “P” button on the control box initiates the Autopark sequence. Once initiated, the “Emergency Stop”COMMAND LIGHT SL422D SHADOW Series Versatile Flood Lighting - Icon 3 button indicator is illuminated. Pressing the “Emergency Stop”COMMAND LIGHT SL422D SHADOW Series Versatile Flood Lighting - Icon 3 button will cancel the Autopark sequence.
Autopark Sequence
Press green button on the controller once. It does not need to be held in position. The Autopark sequence begins:

  1. “Emergency Stop” COMMAND LIGHT SL422D SHADOW Series Versatile Flood Lighting - Icon 3light is illuminated.
  2. Lamps are extinguished.
  3. Upper stage begins rotation to the center position. If equipped with back light option, back light begins oscillation and returns to the home position.
  4. Once upper stage is centered, rotation stops, lower stage begins retracting.
  5. After lower stage has fully retracted, upper stage begins retracting. Upon upper stage retracting fully, “Emergency Stop”COMMAND LIGHT SL422D SHADOW Series Versatile Flood Lighting - Icon 3 light turns off.

Controller

COMMAND LIGHT SL422D SHADOW Series Versatile Flood Lighting -Controller

Installation

CAUTION
The SHADOW RTB must be installed by a designated installation facility or by an EVT certified Level FA4 Technician. All safety precautions must be thoroughly understood before installation. Please consult the factory for additional installation information assistance. Improper installation can cause overheating of electrical power wires that could catch fire and void the warranty.
Ensure all wiring is properly protected with correct sized breakers and fuses before connecting to the power source.
DC powered light towers require a high current draw to provide high levels of lighting. Verify all
connected electrical components are able to handle the load for this light tower as listed in the Technical
Specifications on page 17.
If in doubt, contact Command Light at 1-800-797-7974 or info@commandlight.com.
Installation Kit
Included with the SHADOWRTB is an installation kit. Verify that the kit contains the following items:
(1) 25 feet of 2GA-2 Conductor power cable (1) 25 feet of 22GA-20 conductor cable
(1) Pre-wired HOLSTER BOX w/cover
(1) Handheld Controller
(1) Small hardware parts bag with:
(4) mounting spacers
(4) 5∕16-18 X 2 ½” bolts
(4) 5∕16-18 nylon lock nuts
(8) 5∕16″ flat washers
(4) large diameter flat washers
(2) ¼-20 x 5∕8″ Phillips pan head machine screws
(4) ¼” flat washers
(2) ¼-20 nylon lock nuts
(1) ½” 90° sealing connector w/nut
Tools Required
Lifting device (crane, forklift, block and tackle, etc.)
Sling for lifting Drill 21 /64″, 17 /64″ drill bits Hole punch for metal with 7 /8″ and 15 /16″ diameter capacity Phillips head screwdriver, #2 COMMAND LIGHT flat blade screwdriver (included with light) 7 /16″ and 1 /2″ combination wrenches and/or ratchet and 7 /16″ and 1 /2″ sockets 8″ adjustable wrench Tongue and Groove Pliers Wire stripper or razor blade knife Solder-less wire connector crimp tool Silicone based gasket sealer, RTV™ recommended

Installation Notes

The SHADOW RTB weighs approximately 75 pounds. Use mechanical assistance such as a forklift or crane to lift the light into installation position.
Use the provided fender washers under the mounting surface to distribute the weight load evenly.
When routing the connecting electrical wires take care to avoid sharp bends, hot components or other hazards to the wire.
The SHADOW RTB is not designed to be operated in a raised position while the vehicle is in motion. The SHADOW RTB includes warning circuit wiring to enable a warning device.
Location Requirements The standard SHADOW RTB can be mounted on any location that is 34″ x 22″. The surface should be flat or have only a slight crown. For a recessed installation allow for a minimum of 60″ x 38″. Consult with factory before construction  f recessed installation. Verify all dimensions before installation to assurem proper operation of light will not infringe on other installed components. For all other installations refer to the dimensional drawing on page 17 of this guide that represents your particular model of light. The drawings reflect the dimensions of the “working envelope” of a typical light. Endure sufficient clearances are incorporated in your installation to allow for variations (vehicle body flex, environmental conditions, future servicing needs, etc.)

COMMAND LIGHT SL422D SHADOW Series Versatile Flood Lighting -ervicing need

Four mounting bolts are required. Additional holes may be drilled in the frame ends if necessary to clear obstructions.
Access holes for the power cord cabling should be in close proximity to the entrance box on the light.
Installing the cords with a sweeping 90° or 180° bend will provide better results.
The control box holster should be mounted in an area shielded from the weather. Allow a minimum of 10″ clearance above the control box holster mounting location for easy access to the controller.

Mounting

Place the provided spacers in the location of the light mounting holes. The spacers may be modified to conform to the contour of the mounting location.
Remove any obstructions below the mounting surface such as headliners. Attach any necessary lifting attachments to the SHADOW RTB . The center of gravity (balance point) is slightly below the rotation assembly.

COMMAND LIGHT SL422D SHADOW Series Versatile Flood Lighting - Mounting

Warning CAUTION
Slowly lift the SHADOW RTB and check for balanced lifting. Lower and make any necessary adjustments to the lift points.
Lift and place the SHADOW RTB into position above the spacers. Before placing the full weight of the light tower on the spacers, align spacers with the holes in the end frame castings. Drill 21 /64″ holes in the mounting surface using the end casting holes as a template. Fasten the light using the provided hardware. To assure a weather-tight installation apply a thin bead of silicone based gasket sealer to the base of the spacer and underside of bolt head. Remove any lifting straps and devices from the SHADOW RTB . Locate and drill the wire feed holes.
Control Box Holster Mounting
Using the holster as a template, mark locations of holes. Drill 17 /64″ mounting holes. Drill any holes required to route the control wire from the control box to the SHADOW RTB .
Mount holster box with provided hardware.

Electrical Wiring

Please Note: Detailed internal wiring schematic for the light is found in the supplement pages found at the end of this document.
Run the control wire from the control box holster to the SHADOW RTB .
Run the power wire from the breaker box or generator to the SHADOW RTB . A 100 Amp breaker is recommended on DC models.
Make the control cable connections in the SHADOW RTB relay box by matching each control wire to its same color on the connector block of the SHADOW RTB relay box. The SHADOW RTB model SL442D comes pre-wired to connect to 12 VDC.
12 VDC

COMMAND LIGHT SL422D SHADOW Series Versatile Flood Lighting - 12 VDC

 

Warning Device Installation

The SHADOW RTB nest sensor can be used to activate a warning device when the light is extended. Typically the vehicle will have a light or buzzer that activates when the compartment doors are open. The connector for hooking up a warning device is located in the holster box that holds the control unit.

Maintenance

Cleaning
The SHADOWRTB is constructed with corrosion resistant aluminum and stainless steel fasteners. To further enhance corrosion resistance all exposed surfaces receive a powder coated paint finish. To assure years of trouble free service periodically clean all external surfaces with a mild detergent solution and a gentle spray of water. DO NOT USE A HIGH-PRESSURE WASHER, which will force water into sensitive electric circuitry. Lamp lenses may be cleaned with any commercially available glass cleaner. The lower stage actuator is a sealed unit and does not require adjustment or lubrication. They also have a slip-clutch to compensate for minor stroke tolerances at the limits of its travel as well as internal limit switches. The actuator may produce a ratcheting sound at each end of the stroke which is normal. The actuator should not be made to ratchet excessively, this can lead to premature actuator clutch failure. All pivot points on the SHADOW RTB are self-lubricating thermal polymer. Periodic cleaning with a moisture displacing cleaner and soft bristle brush, without disassembly, to remove accumulated dirt and debris will minimize wear.
Power Failure
The SHADOW RTB can be retracted manually if power to the unit is lost. If power loss is temporary, reestablishing power may be easier than manually retracting the light.
warning - 1 WARNING
Disconnect power source from the SHADOW RTB.
Rotate to Center
Slowly apply pressure to the midplate to manually rotate to the centered position. Trying to rotate the midplate too quickly or with too much pressure can break the rotation motor shaft. Be certain that you rotate the midplate in the proper direction as the lamp tree can rotate only 350˚.
Retract the Lower Stage
Locate the silver plug located on the actuator below the actuator’s motor. Use the provided hex tool (6mm hex bit) to remove silver plug. Be sure to not lose this plug. Use the same hex tool inserted into the opening to drive the internal gears of the actuator. Be sure to replace the silver plug after this actuator is fully retracted.

Troubleshooting

Problem Possible Cause Solution
Unit will not extend No power to the unit Check power input connections. Ensure 100 Amp input breaker has not been tripped.
Incorrect installation Refer to installation instructions.
Upper stage will not rotate Lower stage not raised above 16″ Raise lower stage higher.
Rotation motor failure. Consult with factory.
Lights will not illuminate. Lower stage not raised above 16″ Raise lower stage higher.
Circuit breaker tripped. Check circuit breaker at power supply.
No power to the unit. Check power supply operation/ output.
Unit will not nest Lamp tree not centered Raise lower stage higher than 16″. Center lamp tree (green light illuminated)
Unit being operated on a slope >50. Level Truck. If problem persists, rotate lamp tree to center, using a pike pole, hold unit centered while lowering to nest position.
Autopark button must be held in to park unit Faulty or stuck nest switch. Check nest switch ground and operation. Rubber boot may have shrunk and is holding in switch.
Water in electronics. Remove moisture from ground points and electronics. Do not use a pressure washer to clean unit.
No lights or rotation Check safety limit sensor, bad, etc. Contact factory for replacement part.
Autopark is off Center Center switch out of alignment. Contact factory for replacement part.

COMMAND LIGHT SL422D SHADOW Series Versatile Flood Lighting - 12 VDC 1

 

Technical Specifications – Standard DC Model (SL422D, SL442D)

Dimensions (with strobe and ½” mounting spacers) – May vary by model and options:

Height(Depth)  Length  Width
Retracted 8″ 54″ 34″
Extended 52″ 56″ 34″
Recessed installation 10″ 62″ 40″ Minimum

Weight: 75 pounds
Wiring:

  Main Power VDC 2/2 SO cord 25′ provided
  Control wiring 22/20 PVC Jacketed 25′ provided

Relay protection:
Lights Cole-Hersey 3055 100 amps
Current Draw / Power Requirements:

Fixture Average
2 x 150 Watt LED 12 VDC/40 amps
4 x 150 Watt LED 12 VDC/60 amps
2 x 220 Watt LED 12 VDC/50 amps
4 x 220 Watt LED 12 VDC/90 amps

Lift actuators and rotation motor will cause higher current draw during use.
Motor Duty Cycle:
(All motors thermally protected, specifications are to thermal relay trip):
Lower stage 1:3 (90 seconds maximum per 5 minutes) Rotation 5-6 Revolutions
Motor Speed:
Lower stage 0.5 inches per minute 14 seconds to full extension
Rotation
2.75 RPM at lamp tree
Operation:
Angle of vehicle 15˚ maximum incline

Specifications

COMMAND LIGHT SL422D SHADOW Series Versatile Flood Lighting - Specifications

Parts List – (Base)

PARTS UST
1704 QTY PART NUMBER DESCRIPTION
1 1 178-01100 FRAME,WELDMENT,SHADOW RTB
2 1 178-02300 ARM, MAIN LIFT, WELDMENT,SHADOW RTB
3 1 178-01502 PIN,LOWER,P1VOT,SHADOW RTB
4 1 069-15411 ACTUATOR,LINEAR,ISOMM,12VDC,1A36
5 1 178-01008 ARM,TRAILING,UFT,SHADOW RTB
6 1 178-01501 PIN,LOWER,ACTUATOR,SHADOW RTB
7 1 178-01500 PIN,UPPER,ACTUATOR,SHADOW RTB
8 9 067-14200 BEARING,FLANGED,IGUDEJFI.0809-06
9 7 069-15336 E-Ring, 5133-50, .0447, SS
10 2 065-13084 CAMP,LOOM,#4,SS
11 2 065-12365 ClAMP,LOOM,*6,SS
12 16 069.01140 SCREW,BH,HEX,6x1x16,SS
13 2 069-01126 Nut, MS, M6x1.00
14 1 178-02097 COVER,ACCESS PANEL,UFT ARM,SHADOW RTB
15 1 065-15001 CANISTER,DOCUMENT,BLACK
16 1 178-04053 PAD, NEST, SHADOW RTB
17 1 069-01133 SCREW,BH,HEX,M4x0.7×10,SS
18 2 069-01114 SCREW,FHSH,M6x1x16
19 16 034-11028 WASHER,LOCK,SPRING,REGULAR, 1/4″, SS
20 4 069-01103 SCREW,BH,HEX,6x1x12,SS
21 6 034-13092 SCREW,BH,HDC,M4x0.7×8,SS
22 1 178-02099 BRACKET, NEST SWITCH, SHADOW RTB

Exploded View – (Base)

COMMAND LIGHT SL422D SHADOW Series Versatile Flood Lighting - Exploded View

Parts List – (Mid-Plate)

PARTS LIST
ITEM QTY PART NUMBER DESCRIPTION
1 1 178-03002 PLATE, ROTATION DRIVEN, SHADOW RTB
2 1 069-01103 SCREW,SHCS,SHCS M6x1x12
3 5 034-13683 SCREW,SH SET,M6x1.0 x 16rnm,SS
4 1 178-03010 BEARING,THRUST,ROTATION,SHADOW RTB
5 1 065-12382 RING,SPIROLOX,2-TURN,WS-175
6 1 178-03001 PLATE, ROTATION DRIVE, SHADOW RTB
7 2 178-03006 STANDOFF,MOTOR,ROTATION,SHADOW RTB
8 1 178-04084 MOUNT,MOTOR,ROTATION,SHADOW RTB
9 4 034-13063 SCREW,SHCS,SHCS M4x0.7×30
10 1 034-13066 SCREW,SHCS,SHCS M4x0.7×10
11 1 178-03005 STOP,ROTATION LIMIT,SHADOW RIB
12 2 065-12383 SWITCH,LIMIT,CHERRY,SPDT,5A,125V,SRTEIL
13 4 034-03070 SCREW,PHP,2-56 UNCx0.5
14 1 178-03007 LARGE PULLEY,MID PLATE,SRTBL
15 1 178-03009 CAM,ROTATION CENTER,SHADOW RTB
16 1 069-01133 SCREW,BH,HEX,M4x0.7×10,SS
17 1 178-04077 SWITCH,LIMIT,MIDPLATE,RTB
18 1 034-13092 SCREW,PPH,M4 X 8
19 2 065-12384 BUSHING,BRONZE,1.753 x 2.004 x 1,SRTBL

Exploded View – (Mid-Plate)

COMMAND LIGHT SL422D SHADOW Series Versatile Flood Lighting - Exploded View 1

Parts List – (Lamp Tree)

ITEM QTY PART NUMBER DESCRIPTION
2 2 178-44SFIXT LAMP,SUBASSEMBLY,BACKLIGHT,STD,SHADOW RTB
3 2 178-44SFIXT LAMP,SURA5SEMBLY,FIXED,STD,SHADOW RIB
9 8 034-11033 NUT,NYLOCK, 1/4-20 UNC,SS
10 1 178-04000 TREE,BARE,VVELDMENT,SHADOW RTB
11 1 178-05100 MOUNT, STROBE, SHADOW RTB, WELDMENT
12 1 178-04017 MOUNT,LEFT,BACKLIGHT,SHADOW RTB
13 1 178-04018 MOUNT,RIGHT,BACKLIGHT,SHADOW RTB
14 1 RTB_ESI—Assembly
15 1 065-12867 STROBE, PRE-WIRED, INDICATE COLOR
16 2 034-13092 SCREW,PPH,M4 X 8
17 4 069-01103 SCREW,81-1,HEX,6x1x12,SS
18 1 178-04009 COVER,ACCESS,LAMP TREE,SHADOW RIB
19 10 034-11028 WASHER,LOCK,SPRING,REGULAR, 1/4″, SS
20 6 069-01102 SCREW,BH,HE(,4×0.7×12,SS
21 6 069-01140 SCREW,BH,HEX,6x1x16,SS
23 2 065-12851 STRAIN RELIEF,DOMED 90,SCR .39-.55,1/2 NFT,BLACK
24 1 069-15392 CONXALL, MINICON, 2 PIN, PANEL
25 2 065-12373 PLUG,FINISHING,1×2,SRT-BL,ROM CL
26 4 034-13062 SCREW,SHCS,SPCS M4x0.7×25
28 2 069-01125 Nut, MS, M4x0.7
29 1 065-12827 STRIP, BARRIER, 12 POLE
30 2 034-13288 SCREW,PHP,4-40 UNCx0.75
31 2 034-14283 WASHER,LOCK,18-8SS,INTERNAL,44
32 2 034-10902 NUT,MS,HE(2,440UNC,SS
33 1 034-10975 SCREW,FHPMS,10-24 UNC x 3/4 in,SS
34 1 078-03013 SPACER,DIN RAIL,STROSE MOUNT
35 1 069-01000 RAIL, DIN, SLOTTED, 7.5MM X 35MM 4 in.
36 1 034-13081 NUT,NYLOCK,THIN, 10-24 UNC,SS
37 2 065-10075 BRACKET,END,DIN,DN-EB35
38 1 065-10069 BLOCK,TERMINAL,DIN,DN-T10-8LACK
39 1 065.10068 BLOCKTERMINAL,DIN,DN-T10-BLUE
40 1 065-10073 BLOCKTERMINAL,DIN,DN-T10-WHITE
41 1 065-10074 BLOCK,TERMINAL,DIN,ON-T10-YELLOW
42 2 065-10070 BLOO(,TERMINAL,DIN,DN-T10-GREEN
43 1 065-10068 BLOCK,TERMINAL,DIN,ON-T10-8LUE/WHITE
44 1 069-01134 SCREW,BH,HEX,M4x0.7×16,SS
45 1 069-01133 SCREW,8l1,HEX,M4x0.7×10,SS

Exploded View – (Lamp Tree)

COMMAND LIGHT SL422D SHADOW Series Versatile Flood Lighting - Lamp Tree

Parts List – (Backlight)

PARTS UST
ITEM QTY PART NUMBER DESCRIPTION
1 2 178-04002 SUPPORT,SHAFT,FIVOT,SHADOW RTB
2 1 178. SHAFT,DRIVEN,SHADOW RIB
3 2 MFI-1620-10 BuSHING,FLANGED,IGLIDE,MF1-162040
4 1 178-04003 PULLEY,HTD,SRT BACK UGHT,RAW
5 1 178-04016 SHIMGPACER,BACKLIGHtSHADOW RIB
7 1 065.12374 MOTOR,THRU HOLE,12 VDC
8 1 178-04010 SHAFF,STUB,DRIVE,SHADOW RTB
9 1 065-12378 PULLEY,HTD,P5mm,W15mm,G17,DF,B8mm
10 1 065-12376 BELT,HTD,P5mm,GSS,SRT BL
11 2 178-04007 STOP,ROTATION,BACBLIGHT,SHADOW RTB
12 2 069-01140 SCREW,BH,HEX,6x1x16,SS
13 2 034-11029 WASHER,FLAT,USS, 1/4″, SS
14 2 034-11028 WASHER,LOMSPRING,REGULAR, 1/4″, SS
15 2 SID HARDWARE-10%0-52 WASHER,LOCK,18-1355,DMERNAL,1/410
16 1 S11) HARDWARE-PHP-49 SCREW,PHP,MS,10-24UNCX1-3/4,SS
17 1 034-10981 NUT,NYLOO(, 10-24 uNC,SS
18 1 069-01133 SCREW,I3H,HEX,M4#0.7×10,SS
19 1 034-11124 WASHER,FLAT,FENDER, 10 X 11/16, SS
20 1 034-10947 WASHER,FLAT,SAE, #8, 55
21 1 034-11175 WASHER,LOCX,SPRING,REGULAR, 1113, SS
22 8 069-01103 SCREW,BH,HEX,6x1x12,SS
23 2 069-14160 SENSOR,PROXIMITY,4-WIRE
24 4 SCREW,PHP,2-56 UNOt0.75
STD HARDWARE-07
25 4 SID_HARDWAFtE-10301 NUT,MS,NE(1,2-56UNC,S5
26 1 178-04024 GuARD,BELT,EILIGHT,SHADOW RIB
27 1 065-12380 RING, RETAINING,1″ STAINLESS STEEL
28 1 178-04027 MOUNT,MOTOR,DRIVE,AERIAL

Exploded View – (Backlight)

COMMAND LIGHT SL422D SHADOW Series Versatile Flood Lighting - Lamp Tree 1

Parts List – DC Relay Box

PARTS LIST
ITEM QTY PART NUMBER DESCRIPTION
1 1 178-04075W WELDMENT, RELAY BOX EXT., SHADOW RTB
2 1 065-14784 LOOKUP LIGHT,LED, KNIGHT,SHADOW
3 2 065-12854 STRAIN RELIEF,DOMED,SCR .51-.71,3/4 NPT,BLACK
4 3 065-12852 STRAIN RELIEF,DOMED,SCR .24-A7,1/2 NPT,BLACK
5 2 065-12857 LOCKNUT,NYLON,3/4 NPT,BLACK
6 3 065-12856 LOCKNUT,NYLON,1/2 NPT,BLACK
7 1 178-04076 BRIDGE, ELECTRICAL, RELAY BOX, RTB
12 1 065-13507 BREAKER,100 AMP,MANUAL RESET
15 2 065-12828 TERMINAL STRIP,16 POLE
16 6 034-10919 SCREW,PHP,6-32 UNCx0.75
17 6 034-11162 NUT,MS,HEX2,6-32UNC,SS
19 1 079-00005 PLATE,RELAY MOUNT,ALL
20 2 034-10966 SCREW,PHP,10-24 UNCx0.75
21 6 034-10978 WASHER,LOCK,18-8SS,INTERNAL,#10
22 2 034-13100 NUT,MS,HEX2,10-24UNC,SS
23 6 034-10961 SCREW,PHP,10-24 UNCx0.375
24 6 034-10981 NUT,NYLOCK, 10-24 UNC,SS
26 1 065-14187 RELAY SOCKET,3A,14 PIN,SRT BUILDS
27 1 065-14186 RELAY,BL,AUTO PARK,CL,SRT,MY2KDC12
28 2 034-11187 SCREW,FHPMS,6-32 UNC x 3/4 in,SS
29 2 034-13098 NUT,NYLOCK, 6-32 UNC,SS
30 1 065-13529 BREAKER, 12V 20A, SINGLE POLE
31 22 065-13730 Socket, Single Pole, Relay
32 22 065-13738 RELAY, 12V, SINGLE POLE
33 12 034-10939 SCREW,PHP,8-32 UNCx0.5
34 12 034-10951 NUT,NYLOCK, 8-32 UNC,SS
35 1 065-12890 STRIP, BARRIER, 20 POLE
36 4 034-13682 WASHER,LOCK,18-8SS,INTERNAL,#6
37 1 034-13690 SCREW,PHP,1/4-20 UNCx1.25
38 3 034-10110 WASHER,LOCK,18-8SS,INTERNAL,1/4in
39 3 034-11112 NUT,MS,HEX2,1/4-20UNC,SS
41 1 065-12792 STRAIN RELIEF,DOMED,SCR .71-.98,1 NPT,BLACK
42 1 065-12791 LOCKNUT,NYLON,1 NPT,BLACK
43 1 178-04074 COVER,RLY BOX,SHADOW RTB, EXTENDED
44 1 034-11016 SCREW,HH,1/4-20×3/4,SS
45 1 034-11028 WASHER,LOCK,SPRING,REGULAR, 1/4″, SS
46 4 034-10968 SCREW,PHP,10-24 UNCx1
47 1 069-15360 SWITCH, DOWN LIMIT / NEST / BL LIMIT
48 1 065-12935 BOOT,PUSHBUTTON,BLK,BACK LIGHTS
49 3 069-15360 NUT,SWITCH, DOWN LIMIT / NEST / BL LIMIT

Exploded View – DC Relay Box

COMMAND LIGHT SL422D SHADOW Series Versatile Flood Lighting - Relay Box

Wiring Schematics

COMMAND LIGHT SL422D SHADOW Series Versatile Flood Lighting - Schematics

Holster Box

COMMAND LIGHT SL422D SHADOW Series Versatile Flood Lighting - Holster Box

Holster Box

COMMAND LIGHT SL422D SHADOW Series Versatile Flood Lighting - Holster Box 1

STANDARD

COMMAND LIGHT SL422D SHADOW Series Versatile Flood Lighting -CONTROLLER 1

COMMAND LIGHT SL422D SHADOW Series Versatile Flood Lighting -CONTROLLER 2

COMMAND LIGHT SL422D SHADOW Series Versatile Flood Lighting -CONTROLLER 3

1-800-797-7974
www.CommandLight.com
COMMAND LIGHT Logo3842 Redman Drive
Fort Collins, CO 80524
PHONE: 1-800-797-7974
FAX: 1-970-297-7099
WEB: www.CommandLight.com

Documents / Resources

COMMAND LIGHT SL422D SHADOW Series Versatile Flood Lighting [pdf] User Guide
SL422D, SL442D, SL422D SHADOW Series Versatile Flood Lighting, SHADOW Series Versatile Flood Lighting, Versatile Flood Lighting, Flood Lighting, Lighting

References