Danfoss React™ RA click Thermostatic Sensors Series

Installation Guide

Product Codes: 015G3090, 015G3080, 015G3290

Installation

Installation | Montage | Installation | Instalación

Step 1: Attach the thermostatic sensor to the radiator valve. Diagram shows the sensor being screwed onto the radiator valve body.

Diagram: Sensor being attached to a radiator valve.

Step 2: Connect the sensor to the valve. Diagram shows a close-up of the sensor clicking onto the valve connection point.

Diagram: Close-up of sensor connection to valve.

Step 3: Ensure the sensor is securely attached. A 'click' sound indicates proper engagement. Diagram shows the sensor fully attached to the valve.

Diagram: Sensor fully attached, with 'click' indicator.

BIV Installation

BIV Installation | Montage | Installation | Instalación

Step 1: Attach the sensor to the valve. Diagram shows the sensor being attached to a radiator valve.

Diagram: Sensor being attached to a radiator valve.

Step 2: Connect the sensor to the valve. Diagram shows a close-up of the sensor clicking onto the valve.

Diagram: Close-up of sensor connection to valve.

Step 3: Ensure the sensor is securely attached. A 'click' sound indicates proper engagement. Diagram shows the sensor fully attached to the valve.

Diagram: Sensor fully attached, with 'click' indicator.

Uninstall

Uninstall | Deinstallieren | Désinstaller | Uninstall

Step 1: Remove the sensor from the valve. Diagram shows the sensor being pulled away from the valve.

Diagram: Sensor being removed from valve.

Step 2: To release the sensor, a tool (like a screwdriver) may be needed to disengage a locking mechanism. Diagram shows a screwdriver being used on a part of the sensor, with a cross symbol indicating an incorrect action or warning.

Diagram: Tool used to release sensor lock.

Temperature Limitation (MAXIMUM)

Temperature Limitation | Temperaturbegrenzung | Limite de température | Limitación de temperatura (MAXIMUM)

Step 1: Set the desired maximum temperature. Diagram shows the dial set to '2'.

Diagram: Dial set to 2.

Step 2: To set the maximum limit, turn the dial to the highest desired setting, for example, '5' (MAX).

Diagram: Dial set to MAX (5).

Step 3: Example: Setting the maximum to '4'. Diagram shows the dial set to '4'.

Diagram: Dial set to 4.

Step 4: Example: Setting the maximum to '4' (MAX = 4). Diagram shows the dial set to '4'.

Diagram: Dial set to 4 (MAX=4).

Step 5: Example: Setting the maximum to '4' (MAX = 4). Diagram shows the dial set to '4'.

Diagram: Dial set to 4 (MAX=4).

Temperature Limitation (MINIMUM)

Temperature Limitation | Temperaturbegrenzung | Limite de température | Limitación de temperatura (MINIMUM)

Step 1: Set the desired minimum temperature. Diagram shows the dial set to '2'.

Diagram: Dial set to 2.

Step 2: To set the minimum limit, turn the dial to the lowest desired setting, for example, '1' (MIN).

Diagram: Dial set to MIN (1).

Step 3: Example: Setting the minimum to '1'. Diagram shows the dial set to '1'.

Diagram: Dial set to 1.

Step 4: Example: Setting the minimum to '2' (MIN = 2). Diagram shows the dial set to '2'.

Diagram: Dial set to 2 (MIN=2).

Step 5: Example: Setting the minimum to '2' (MIN = 2). Diagram shows the dial set to '2'.

Diagram: Dial set to 2 (MIN=2).

Theft Protection

Theft protection | Diebstahlschutz | Protection contre le vol | Protección contra robo

Step 1: Diagram shows the sensor with a locking mechanism.

Diagram: Sensor with locking mechanism.

Step 2: A screwdriver is used to engage the locking mechanism.

Diagram: Screwdriver engaging lock.

Step 3: A part is inserted into the sensor to activate theft protection.

Diagram: Part insertion for theft protection.

Step 4: The theft protection is now engaged on the installed sensor.

Diagram: Theft protection engaged.

Available Parts:

Theft Protection (Removal)

Theft protection (Removal)| Diebstahlschutz (Entfernung) | Protection contre le vol (enlèvement) | Protección contra robo (eliminación)

Step 1: Use a screwdriver to release the theft protection mechanism.

Diagram: Screwdriver releasing theft protection.

Step 2: Remove the theft protection part from the sensor.

Diagram: Theft protection part removed.

Available Parts:

Blind Mark

Blind mark | Blinde markierung | Marque aveugle | Marca ciega

The sensor features a blind mark (indicated by the number '3' on the dial) for users with visual impairments. Diagram highlights the number '3' on the sensor dial, indicating a blind mark for visual impairment, along with a small indicator.

Diagram: Sensor dial showing blind mark '3'.

Contact & General Information

For more information, visit danfoss.com or contact Danfoss A/S at +45 7488 2222.

Danfoss Climate Solutions | 2023.03

Document reference: AN448339341662en-000101

Information provided by Danfoss is for guidance only and is binding only when explicitly referenced in a quotation or order confirmation. Danfoss reserves the right to alter products without prior notice. Trademarks are property of Danfoss A/S or its group companies.

Models: 015G3090, 015G3080, 015G3290, 013G5245, 013G1236, React RA Click Thermostatic Sensors, React RA Click, Thermostatic Sensors, Sensors

PDF preview unavailable. Download the PDF instead.

AN448339341662en-000101 Danfoss A/S Adobe PDF library 17.00

Related Documents

Preview Danfoss React RA click Thermostatic Sensor Installation Guide
Official installation guide for the Danfoss React RA click thermostatic sensor series, covering installation, uninstallation, temperature limitation, and theft protection features. Includes model numbers and product details.
Preview Danfoss Redia® RA click Thermostatic Sensor Installation and User Guide
Comprehensive guide to installing, operating, and maintaining the Danfoss Redia® RA click thermostatic sensor series. Learn about temperature limitation, shut-off, and theft protection features.
Preview Danfoss React RA Click Thermostatic Sensor Installation and User Guide
Detailed installation, uninstallation, and setup guide for the Danfoss React RA Click thermostatic radiator valve sensor series. Covers remote sensor installation, temperature limitation (max/min), and theft protection features. Includes product codes and model information.
Preview Danfoss Redia RA click Thermostatic Sensor Installation Guide
Comprehensive installation guide for the Danfoss Redia RA click thermostatic sensor series, covering installation, BIV installation, uninstallation, temperature limitation (maximum and minimum), and theft protection features.
Preview Danfoss React™ M30 x 1.5 Thermostatic Sensor Installation Guide
Comprehensive installation guide for the Danfoss React™ M30 x 1.5 thermostatic sensor series, covering mounting, temperature limitation, shut-off, and theft protection. Learn how to install and set up your Danfoss radiator valve.
Preview Danfoss Mio Presetting Instructions: Installation Guide for HVAC Valves
Comprehensive installation guide for Danfoss Mio thermostatic radiator valves (TRVs), detailing presetting instructions and Kv-value capacities for various models and sizes.
Preview Danfoss Aveo® RA click Thermostatic Sensors Installation Guide
Comprehensive installation, uninstallation, temperature limitation, and theft protection guide for the Danfoss Aveo® RA click thermostatic sensors series. Includes part numbers for associated tools.
Preview Danfoss Redia RA click with RA-N Installation Guide
Official installation guide for the Danfoss Redia RA click thermostatic radiator valve with RA-N actuator, detailing valve and sensor installation, torque specifications, and presetting options.