CNCU-LOGO

CNCU FC300 Easy Route CNC Router

CNCU-FC300-Easy-Route-CNC-Router-PRODUCT

Specifications

  • Model: BEST FC300
  • Manufacturer: AM.CO.ZA
  • Maximum Frequency: 400MHz

Product Usage Instructions

  • Inverter Settings:
    • P087 = 101: Reset Inverter Parameter to Factory Default
    • P017 = 0.5: Stop Breaking Time, set to 0.5 seconds
    • P018 = 5: DC Breaking Voltage, set to 5%
    • P038 = 4: Acceleration Time, set to 4 seconds
    • P039 = 5: Deceleration Time, set to 5 seconds
    • P021 = 400: Maximum frequency for spindles is 400MHz
    • P030 = 0: Multi-speed frequency 0
    • P031 = 100: Multi-speed frequency 1
    • P032 = 150: Multi-speed frequency 2
    • P033 = 200: Multi-speed frequency 3
    • P034 = 250: Multi-speed frequency 4
    • P035 = 300: Multi-speed frequency 5
    • P036 = 350: Multi-speed frequency 6
    • P037 = 400: Multi-speed frequency 7 (Speed on Panel)
    • Reboot the system after changing all parameters. Refer to the BEST FC300 Manual for detailed instructions on parameter modification.
  • Wiring Instructions:
    • You may need to connect GND to PE/COM if it’s not already grounded.

FAQs

  • Q: How do I reset the Inverter Parameters to Factory Default?
    • A: Set P087 to 101 and reboot the system.
  • Q: What is the maximum frequency supported by the inverter for the spindles?
    • A: The maximum frequency supported is 400MHz.
  • Q: Do I need to change all default settings for normal operation?
    • A: The default settings should work fine, but you may adjust  specific parameters based on your requirements.

“`

BEST FC300 Inverter Settings and Wirings for EasyRoute CNC Router
https://am.co.za/

P087 = 101

Set this value to reset Inverter Parameter to Factory Default, all below settings are based on default

(Reboot after Reset, then change:)

P017 = 0.5

Stop Breaking Time, 0.5 seconds

P018 = 5

DC Breaking Voltage, 5%

P038 = 4

Acceleration Time, 4 seconds

P039= 5

Deceleration Time, 5 seconds

(Those should be on default, unless you want to change each gear frequency)

P021 = 400

Maximum frequency for our spindles is 400MHz

P030 = 0

Multi-speed frequency 0

SOFF

P031 = 100

Multi-speed frequency 1

S1

P032 = 150

Multi-speed frequency 2

S2

P033 = 200

Multi-speed frequency 3

S3

P034 = 250

Multi-speed frequency 4

S4

P035 = 300

Multi-speed frequency 5

S5

P036 = 350

Multi-speed frequency 6

S6

P037 = 400

Multi-speed frequency 7

S7 Speed on Panel

Reboot One More Time After All Parameters Changed.

BEST FC300 Manual on CNCU.CO.ZA Page 18, section “3. 4. Parameter modification method” explained how to change above values. Wiring:

You may need to connect GND to PE/COM if its not ground already.