Ceretone Core One Pro User Guide

Ceretone Core One Pro

Ceretone Core One Pro

Get Started In 6 Easy Steps

Get Started In 6 Easy Steps

Congratulations on your new Core One Pro!
Like many new products, there may be a learning curve as you become familiar with your hearing aids. At times, you may even feel tempted to give up. However, with a little patience and the help of this Quick Start Guide, you’ll be up and running in about 30 minutes.
Core One Pro is designed for adults with mild to moderate hearing loss. As you begin using your new hearing aids, give yourself time to adjust to the sounds around you and rediscover the conversations and moments you’ve been missing.
Your journey to better hearing begins today.

Device Diagram

  1. Left Button (L)
  2. Charging Slots
  3. Left Hearing Aid Indicator
  4. Charging Case Indicator
  5. Right Button (R)
  6. Right Hearing Aid Indicator
  7. Upper Cover
  8. Charging Port
    Device Diagram

Replacement Parts: For replacement parts contact customer support.

Charging

For best performance, fully charge before first use. A full charge provides up to 20 hours of use, and the charging case provides up to 60 additional hours of listening time. Full charging takes approximately 2.5 hours.

Charging

  • Charge the device to activate before first use.
    Charging

Step 1 – Wear Your Device

  1. Identify Your Hearing Aids (I)
    The Left is marked blue & the Right is marked red.
  2. Insert Your Hearing Aids (II)
    Grip the hearing aids with two fingers and place them into your ear with the thread pointing down.
  3. Wait Five (5) Seconds
    The hearing aids will turn on automatically, you will hear a “power on” voice prompt.

Note: When wearing your hearing aids, accidentally covering the sound inlet (III) may cause a slight whistling sound. This is normal and should stop once you adjust the hearing aid properly or the obstruction is removed.

  1. Identify
    Wear Your Device
  2. Insert
    Wear Your Device
  3. Sound Inlet
    Wear Your Device

Step 2 – Find Your Eartip Fit

An incorrect eartip size may cause whistling or feedback. Try a different size or style for a better fit. Your hearing aids include XS, S (preinstalled), M, and L dome eartips, plus flower-style eartips for added comfort and preference.

Smaller Eartips
If the device feels too difficult to insert or is uncomfortable.
Larger Eartips
If you experience whistling.

  • Flower Tip
    Find Your Eartip Fit
  • Dome Tip
    Find Your Eartip Fit

Note: Gently pull the eartips to ensure they are securely attached.

Change Eartip

  1. Remove the eartips.
  2. Choose the proper size.
  3. Align the Sound Outlet with the new eartip and align its Notch with the curve of the hearing aid. (1) Press into place until you feel a click. (II)
    (1) Align notch
    Change Eartip
    (II) Push and click onto Sound Outlet
    Change Eartip

Step 3 – Volume Control

  1. Place one or both hearing aids back into the charging case,
  2. Short-press the Button to increase the volume.
    Adjust Volume With Button
    Volume Control
    Six Levels Of Volume
    Volume Control

Note: The only way to change volume is through the characin case.

Volume Control
Note:
 The volume bar of the charging case screen will indicate the change.

Step 4 – Changing Programs

P1 Standard Ideal for everyday conversations at home or in the office.
P2 Restaurant Best for noisy environments such as restaurants or crowded areas.
P3 Outdoor Suitable for open areas with natural background noise, like parks.
P4 Tinnitus Designed to help ease tinnitus symptoms.

Important Notes for Program 4: (a) Designed to help ease tinnitus symptoms. (b) Do not use for more than 30 minutes at a time, and no more than three (3) times per day. (c) Always consult your physician for ongoing tinnitus treatment and guidance.

Method 1
Quickly double-tap your ear with your hand to switch hearing programs.
Changing Programs

Method 2

  1. Place the hearing aids back into the charging case.
  2. Press and hold the Button for about three (3) seconds to switch the hearing program.
    Changing Programs

Note: The charging case screen will indicate the change.

Step 5 – Clean Your Device

Inspect the hearing aids, eartips, and charging case regularly. Remove any earwax or debris from your device by using the enclosed cleaning tool.

  1. Clean the charging contacts of the rechargeable hearing aids with a cleaning cloth regularly to ensure normal charging.
  2. Eartips should be replaced every 3-6 months or when they become stiff, brittle, or discolored.
    Clean Your Device

Step 6 – Adjusting To Your Device

Adjusting to new hearing aids can take one to three months. Have patience and practice consistently. With time, you’ll notice an improvement in your overall hearing experience.

Week 1 -Wear Your Hearing Aids 1-2 Hours Per Day. Focus on listening and familiarizing yourself with a variety of sounds within the comfort of your home.
Week 2 – Wear Your Hearing Aids 3-4 Hours Per Day. Venture into quiet public places, actively listen, and try to interact with other people.
Week 3 – Wear Your Hearing Aids 4-5 Hours Per Day. Enter noisy public environments. Engage in conversations and continue practicing active listening.
Week 4 – Wear Your Hearing Aids 6+ Hours Per Day. Embrace your newfound hearing abilities! Just remember to take breaks if your ears need them.

FAQ

25-Day Adjustment Period

Your hearing may need time to adjust to sounds that feel new or unfamiliar. We recommend using your hearing aids consistently throughout the 25-day adjustment period to allow your brain and hearing to gradually adapt.

During this time, you may need to make small adjustments to the fit, volume, or settings. For assistance using your devices or improving your listening experience, please contact our customer support team.

Limited Manufacturer Warranty
Cere tone hearing aids are covered by a one-year limited manufacturer warranty beginning on the original date of purchase. This warranty covers defects in materials and workmanship under normal use. During the warranty period, Cere tone will repair or replace eligible defective products at no charge, subject to warranty terms and verification of purchase.

The warranty does not cover damage caused by misuse, accidents, unauthorized repairs or modifications, improper care, normal wear and tear, or loss of the product.

Technical Specifications

Test Standard: ANSI S3.22-2014
Test Equipment: FONIX 8000
Test Coupler: HA-1
Operation environment: Temperature: 0°C-40 C, Relative
humidity: 30%-75%RH, Atmospheric pressure range: 86-106kPa
Storage & transportation environment: Temperature: – 10 C-+55 C,
Relative humidity 10%-90%, Atmospheric pressure range: 70-106kPa

Technical specifications
Test Items Nominal Value, Program 1
Max. Output(OSPL90) 105dB
HFA Full-on Gain (FOG50) 12dB
The total harmonic distortion 2%
Equivalent input noise 23dB
The latency value 6ms
Frequency response bandwidth F1=200Hz F 2=54OOHz
Frequency response smoothness 6dB
Battery life
Test Items Value
Battery life of hearing aids 20h

The data is derived from the measured value of the product at the laboratory, not guaranteed values.
Technical Specifications

Customer Support

Is this guide not quick enough?
Contact our customer support to put you back on track to hearing aid success.

Monday – Friday, 8am – 5pm PST
Phone: (866) 283-4262
Email: support@ceretone.com
https://support.ceretone.com

Logo

Documents / Resources

PDF thumbnailCore One Pro
User Guide · Ceretone, Core One Pro, Hearing Aid

References

Ask a Question

Use this section to ask about setup, compatibility, troubleshooting, or anything missing from this manual.

Ask a Question

Ask about setup, compatibility, troubleshooting, or anything missing from this manual. Name and email are optional.