Connect YELLOW wires of all heads together for synchronization (All heads must be set at the same pattern)
For Simultaneous or Alternating Flash
- Apply +VDC to RED and YELLOW wires simultaneously to enter Grouping mode; lighthead will display short (single or double) flashes:
- Single flash = Group1
- Double flash = Group2
- Remove YELLOW wire from +VDC and momentarily apply to +VDC to change Groups:
- Heads in the same Group flash together.
- Group1 Heads alternate with Group2 Heads
For Flash Patterns:
Momentarily apply +VDC to YELLOW wire:
- once for next pattern
- quickly three times for pattern 0
FP# | Flash Patterns | ||
0 | Random | 6 | Quad |
1 | Single | 7 | Quint |
2 | Single | 8 | 8 Flash |
3 | Mega | 9 | Single-Quad |
4 | Double | 10 | Single H/L |
5 | Triple | 11 | Single-Triple-Quint |
NOTE: This unit may not be factory set at FP# 0.
Adhesive Mount
- Select mounting location and clean surface.
- Peel one side of adhesive and apply to lighthead base.
- Peel other side of adhesive and secure lighthead firmly to the mounting surface
NOTE: Optimun adhesive strength is achieved after 24hrs
Screw Mount
- Select a mounting location.
- Mark and drill mounting holes.
- Place the rubber pad to the bottom of the lighted base.
- Secure light head to the mounting surface with supplied screws
Bracket Mount

- Select a mounting location.
- Place the rubber pad to the bottom of the lighted base.
- Place light head to the mounting surface.
- Align top holes of the bracket onto the lighted base alignment points.
- Secure lightheaded with supplied screws from the bottom of the bracket