Masubay-LOGO

Masubay nga 5002CC Lab Timer

Traceable-5002CC-Lab -Timer -PRODUCT

MGA ALARMA
Each channel has a distinct electronic tone that sounds at the end of its timing period. Channel One has one repeating beep; Channel Two has two repeating beeps; and Channel Three has three repeating beeps. A channel’s tone will sound for 1 minute then shut off automatically to preserve battery life.

PAGKLARO SA PAGPAKITA SA ZERO

Press and hold (approximately 2 seconds) the 1, 2, or 3 button to clear the display to zero for Channel One, Two, or Three respectively. If no channel is active, pressing and holding the 1, 2, or 3 button will shut off the unit entirely.

PANAHON OPERASYON

All three timing channels work essentially the same way, so once you understand how Channel One operates, Channels Two and Three will seem extra easy.

PAG-SET ORAS SA COUNTDOWN

  1. Press the 1 button, digital display will then show all zeros. The symbolTraceable-5002CC-Lab -Timer -1 will be below the 1 button indicating Channel One is displayed.
  2. Set the hours to be timed: Press the H button until the desired number of hours are displayed. For rapid advancement, press and hold button.
  3. Set the minutes to be timed: Press the M button until the desired number of minutes are displayed. For rapid advancement, press and hold button.
  4. Set the seconds to be timed: Press the S button until the desired number of seconds are displayed. For rapid advancement, press and hold button.
  5. When the desired amount of time is showing on the digital display, simply press the 1 button to begin timing. You’ll know timing has begun when the seconds start counting down.
  6. A single repeating electronic tone will sound at the end of the timing period and the symbol below the 1 button indicates status of the timing operation. (See “Channel Indicators” table).
  7. To reset a channel to zero, to turn off a channel, or to turn off a channel while it is timing, simply press and hold down the appropriate channel (Channel One, Two or Three) for two seconds.

NOTA: The tone will continue to sound for 1 minute or until it is turned off. To turn off the tone, simply press the 1 button and release.

EXAMPLES
Channels Two and Three operate the same way as Channel One, except you press the 2 button for Channel Two or the 3 button for Channel Three in every instance you pressed the 1 button when timing in Channel One. Two examples gihatag.

Exampug 1
Time 1 hour, 20 minutes, and 30 seconds in Channel 2:

  1. Pindota ang 2 nga buton.
  2. Press H button once to read “1”.
  3. Press M button until display reads “20” minutes.
  4. Press S button until display reads “30” seconds.
  5. Press 2 button to start timing.
  6. When the tone (two repeating beeps) sounds, press 2 button to turn it off.

Exampug 2
Time 9 hours, 15 minutes, and 10 seconds in Channel 3:

  1. Pindota ang 3 nga buton.
  2. Press H button until display reads “9” hours.
  3. Press M button until display reads “15” minutes.
  4. Press S button until display reads “10” seconds.
  5. Press 3 button to start timing.
  6. When the tone (three repeating beeps) sounds, press 3 button to turn it off.
REVIEWING THE TIME REMAINING IN A CHANNEL
Kung gusto nimo pag-usabview the time remaining in a channel not currently being displayed, simply press the appropriate channel button—1, 2, or 3—and the display will switch to show the time remaining in that channel. Two or more alarms sounding simultaneously If two or more electronic tones sound at one time, the highest numbered channel’s alarm will be sounding; however, all completed timing periods will be indicated on the display. As you turn off the highest channel tone, you will then hear the next highest channel’s alarm. For exampug, kung ang mga yugto sa timing sa duha ka Channels Duha ug Tulo makompleto, imong madungog ang tono sa Channel Three hangtod imong mapindot ang 3 nga buton; unya madungog nimo ang tono sa Channel Two hangtod imong mapindot ang 2 button.
TANANG OPERATIONAL LISOD
If this timer does not function properly for any reason, please replace the batteries with new, high-quality batteries (see “Battery Replacement” section). Low battery power can occasionally cause any number of “apparent” opera-tional difficulties. Replacing the batteries with new, fresh batteries will solve most difficulties.

MGA ESPISPIKASYON

  • Ipakita: ¼* high, 5-digit  LCD
  • Timing capacity: 9 hrs, 59 mins, 59 sec
  • Resolusyon: 1 sec Accuracy: 0.001%
  • Size, weight: 3 x 3 x 1⅜”, 4 oz

DALI NGA REFERENCE

  • A- Channel gipakita
  • B- Channel Usa (1) nga buton
  • C- Channel Duha (2) nga buton
  • D- Channel Tulo (3) nga buton
  • Ang E-Channel dili timing o gipakita
  • Ang F- Channel kay timing pero wala gipakita
  • G- Mga Oras (H) nga buton
  • H- Minutes (M) button
  • I – Seconds (S) button

Traceable-5002CC-Lab -Timer -2

Mga Timaan sa Channel
LCD indicators report the status of each channel.

Traceable-5002CC-Lab -Timer -3

PAGPALIT SA BATERY

To replace the batteries, remove the back housing of the timer by giving the large screw on the back of the unit a half turn with a coin or screwdriver, then replace batteries as shown using two “AA” alkaline batteries. (Do not use regular or heavy-duty batteries. They do not have sufficient power to drive the unit.)

Human sa pagsal-ot sa mga baterya, siguroha nga ang display sa timer normal nga naglihok. Atol sa operasyon sa timing, ang mga bahin sa pagkidlap mahimong makita sa display. Kung mahitabo kini, i-reset lang pinaagi sa pagtangtang ug pagsulud pag-usab sa mga baterya. Ang matag set sa mga baterya kinahanglang molungtad og 1 ngadto sa 2 ka tuig ubos sa normal nga kondisyon. Ang LCD display magpabilin nga blangko kung kinahanglan nga ilisan ang mga baterya.

WARRANTY

WARRANTY, SERBISYO, O RECALIBRATION
Para sa warranty, serbisyo, o recalibration, kontaka ang:

MAHIMO NGA PRODUKTO 12554 Old Galveston Rd. Suite B230 Webster, Texas 77598 USA

Traceable® Products are ISO 9001:2015 Quality- Certified by DNV and ISO/EC 17025:2017 accredited as a Calibration Laboratory by A2LA.

Iring 5002
Ang Traceable® usa ka rehistradong marka sa pamatigayon sa Cole-Parmer.

©2020 Traceable® nga Mga Produkto. 92-5002-00 Pin. 6 070825

Mga FAQ

How do I stop the repeating tone at the end of a timing period?

To turn off the tone, simply press the corresponding channel button 1, 2, or 3 and release.

Mga Dokumento / Mga Kapanguhaan

Masubay nga 5002CC Lab Timer [pdf] Giya sa Gumagamit
5002CC Lab Timer, 5002CC, Lab Timer, Timer

Mga pakisayran

Pagbilin ug komento