Key Features
- Adapter strand 2 for functionalization of heliX® Adapter Chip Spot 2.
- Compatible with heliX® Adapter Chip.
- Includes Adapter strands for 50 regenerations.
- Ideal for MIX&RUN sample preparation.
- Adapter strand 2 carries a moderately hydrophilic red dye (Ra) with a single positive net charge.
heliX® Adapter Chip Overview
The heliX® Adapter Chip features 2 spots with 2 different anchor sequences for DNA-encoded addressing. The diagram illustrates the chip structure: each spot has a fixed anchor strand. Spot 1 has an exchangeable Adapter strand 1, and Spot 2 has an exchangeable Adapter strand 2. The diagram also indicates the presence of a dye and a ligand associated with the adapter strands, and shows that the ligand strand is exchangeable.
Product Description
Order Number: AS-2-Ra-lfs
Table 1. Contents and Storage Information
Material | Cap | Concentration | Amount | Buffer | Storage |
---|---|---|---|---|---|
Adapter strand 2 - Ra - lfs | White | 200/250 nM | 5 x 200 μL | TE40 [1] | -20°C |
For research use only.
This product has a limited shelf life; please see expiry date on label.
To avoid many freeze-thaw cycles, please aliquot the nanolever.
Preparation | MIX&RUN
In-solution hybridization of adapter and ligand strands:
- Mix Adapter strand 1 - Ra (400 nM) and conjugated Ligand strand (500 nM) at a 1:1 ratio (v/v).
- Incubate the solution of step 1 at Room Temperature (RT) at 600 rpm for 30 min to ensure complete hybridization.
- Mix the solution from step 2 and Adapter strand 2 - Ra - Ifs (200 nM) at a 1:1 ratio (v/v).
The solution is ready to use for biochip functionalization.
Stability of the solution is related to the stability of the ligand molecule.
Table 2. Additional material for functionalization of spot 1 and reference spot 2.
Material | Concentration | Buffer | Related Product Name | Order No |
---|---|---|---|---|
Adapter strand 1 - Ra | 400 nM | TE40 [1] | Adapter strand 1 with red dye Ra | AS-1-Ra |
Ligand strand carrying the conjugated ligand | 500 nM | PE40 [2] | heliX® Amine Coupling Kit 1 | HK-NHS-1 |
Example
Required volume for 3 functionalizations: 100 μL with a final concentration of 100 nM.
Vial 1 | Vial 2 | |
---|---|---|
Adapter strand 1 - Ra (400 nM) | 25 μL | |
Conjugated Ligand strand (500 nM) | 25 μL | |
Adapter strand 2 - Ra - Ifs (200/250 nM) | 50 μL |
After incubation time, mix Vial 1 and Vial 2 to obtain 100 μL of ready-to-use DNA solution.
Contact Information
Dynamic Biosensors GmbH
Perchtinger Str. 8/10
81379 Munich
Germany
Dynamic Biosensors, Inc.
300 Trade Center, Suite 1400
Woburn, MA 01801
USA
Order Information: order@dynamic-biosensors.com
Technical Support: support@dynamic-biosensors.com
Instruments and chips are engineered and manufactured in Germany.
©2024 Dynamic Biosensors GmbH | Dynamic Biosensors, Inc. All rights reserved.
Footnotes:
- [1] TE40: 10 mM Tris, 40 mM NaCl, 0.05 % Tween20, 50 μM EDTA, 50 μM EGTA