CDP UPO11-3 Enterprise Level Monitoring Solutions AC Power Modular Datacenters User Guide
CDP UPO11-3 Enterprise Level Monitoring Solutions AC Power Modular Datacenters

High performance double conversion for critical loads and corporate applications

Features

Features

  • Voltage range 60 – 150VAC. Double conversion technology.
  • Frequency regulation at output.
  • Pure sine wave output. Offers greater availability for your equipment, by correcting low and high voltages without using batteries.
  • Zero transfer time.
  • Eliminates 99% of electrical problems.
  • Cold start.
  • Allows fast recovery after overload events.
  • Ideal for protection of medical equipment, laboratory, mission critical servers or telecommunications critical servers or telecommunications.
  • Total isolation of the load from the commercial grid.
  • Maximizes battery performance, life and reliability through intelligent, precision charging intelligent, precision charging.
  • Protects the connected load against short or prolonged surges, lightning, other power irregularities and other power irregularities.
  • Converts input power to direct current (DC) and then to alternating current (AC).
  • Frequency conversion capability.
  • Power factor 0.9 at output.

User friendly LCD Display

User friendly LCD Display

Shows input and output voltages, backup time and battery charge.

Features

4 NEMA 5-15R or 5-20R output terminals

Features

Features
AC power cord NEMA 5-30P

Features
Communication ports

Features
Hard wire output

Features

Option card: SNMP

Features

Option card: EMD (Environmental Monitoring Device)

Features

Task-critical solutions for corporate applications

Model   UPO11-3
Capacity   3000VA
Input   120VAC nominal voltage
Voltage range   60VAC – 150VAC
Frequency range   40Hz- 70Hz
Power factor   >/=0.99 @nominal voltage (full load)
Output    
Output voltage   110/115/120/ 127 VAC
ACvoltage regulation   +1%
Frequency range Battery mode 50 Hz +/-0.1 Hz 60 Hz +/-0.1 Hz
Crest factor   31
Overload   100% – 110: Alarm; 110/130: Battery mode: UPS shuts down in 30 seconds / Normal mode= UPS transfers to bypass mode when power is normal; >130%: Battery mode= UPS shuts down immediately / Normal mode= UPS transfers to bypass mode when power is normal
Harmonic distortion   </=3% THD (linear loads) </= 6% THD (non-linear loads)
Transfer time AC mode to battery mode zero
Waveform   Pure sine wave
Eficiencia    
Modo AC   90%
Modo Eco   96%
Batteries    
Type/Quantity   12v/9Ahx 6
Recharge time   4 hours to recover 90% of its capacity (typical)
Charge current   1,0 Ah (max)
Charge voltage   82,1VDC +/-1%
Backup time   Full charge 4 minutes / Half charge 9 minutes
Environment    
Dimensions (length x height x depth) 190335 x 421mm
Net weight   27.6Kg
Physical    
Humidity   20-90% RH @ 0-45°C (non-condensing)
Noise level   Less than 50dBA @ 1 meter
Control    
Smart RS232 or USB   Supports Windows 2000/ 2003 / XP / Vista / 2008 / 7, 8,10, Linux and Mac
Optional SNMP   Control and command for SNMP and web browser (via internal SNMP or SNMPDBS)
Certifications   NOM, 1509001, 1SO14001, CIDET

Product specifications are subject to change without notice

COP COLOMBIA
colombia@cdpups.com

CDP USA
usa@cdpups.com

COP CHINA
china@cdpups.com

Documents / Resources

CDP UPO11-3 Enterprise Level Monitoring Solutions AC Power Modular Datacenters [pdf] User Guide
UPO11-3 Enterprise Level Monitoring Solutions AC Power Modular Datacenters, UPO11-3, Enterprise Level Monitoring Solutions AC Power Modular Datacenters, Monitoring Solutions AC Power Modular Datacenters, AC Power Modular Datacenters, Modular Datacenters

References

Leave a comment

Your email address will not be published. Required fields are marked *