About S+S Regeltechnik manuals on Manuals.plus

S+S Regeltechnik is a premier European manufacturer specializing in advanced sensor technology for measurement, control, and regulation tasks in building automation and mechanical engineering. Headquartered in Nuremberg, Germany, the company is known for its holistic approach to precision engineering, delivering a wide range of sensors for temperature, humidity, pressure, air quality, and light intensity. Their portfolio includes the intelligent RYMASKON® room controllers and innovative W-Modbus wireless solutions, designed to simplify installation and enhance energy efficiency in modern facilities.

With a commitment to quality 'Made in Germany,' S+S Regeltechnik provides calibratable measuring transducers and robust control units that integrate seamlessly into existing building management systems. Their products support standard protocols like Modbus and offer flexible configuration options, ensuring reliable operation for complex HVAC applications, industrial monitoring, and facility management.

S+S Regeltechnik manuals

Latest manuals from manuals+ curated for this brand.

SplusS 724x-MB Pressure Transmitter Instruction Manual

March 13, 2024
724x-MB Pressure Transmitter Specifications Product Name: Pressure Transmitter Type 724x-MB Dual pressure sensor with 2 measuring channels Measuring transducer for differential pressure and volume flow Included: Connection set, calibratable, with…

SplusS ATM2-T3-MB Temperature Sensor Instruction Manual

March 13, 2024
SplusS ATM2-T3-MB Temperature Sensor Specifications Model: ATM2-T3-MB Type: Temperature sensor Connection: Modbus Material: Stainless Steel V2A (1.4301) Dimensions: 200 x 180 x 150 mm Mounting Instructions Ensure the mounting surface…

SplusS TF65 Temperature Sensor Instruction Manual

March 13, 2024
SplusS TF65 Temperature Sensor Operating And Mounting Instructions Duct temperature sensor, including mounting flange, with passive output High-performance encapsulation against vibration, mechanical stress and humidity Basic device with accessories Mounting…

SplusS KLQ-CO2-MB CO2 & Airquality Sensor Instruction Manual

March 13, 2024
SplusS KLQ-CO2-MB CO2 & Airquality Sensor Product Specifications Product Name: CO2 & Airquality Sensor Type KLQ-CO2-MB Measurement Range: CO2 content, VOC (Volatile Organic Compounds) Accuracy: Calibratable Connection: Modbus Protection Class:…

PREMASGARD® 232x-wModbus: Bedienungs- und Montageanleitung

Operating and Mounting Instructions
Umfassende Bedienungs- und Montageanleitung für den PREMASGARD® 232x-wModbus Druck- und Differenzdruckmessumformer mit W-Modbus (Wireless) von S+S REGELTECHNIK. Enthält technische Daten, Installationshinweise und Konfigurationsdetails.

S+S Regeltechnik manuals from online retailers

THERMASGARD ATM2 Outdoor Temperature Sensor User Manual

1101-1191-0009-900 • September 11, 2025
Comprehensive user manual for the S+S Regeltechnik THERMASGARD ATM2 Outdoor Temperature Sensor, model 1101-1191-0009-900, covering installation, operation, maintenance, troubleshooting, and specifications.

S+S Regeltechnik support FAQ

Common questions about manuals, registration, and support for this brand.

  • What is W-Modbus technology used in S+S Regeltechnik devices?

    W-Modbus is a wireless Modbus RTU architecture operating on the 2.4 GHz ISM band. It features frequency hopping for interference resistance and allows up to 100 nodes to communicate via a single gateway over distances up to 500 meters (open field) without data cables.

  • How do I calibrate S+S Regeltechnik sensors?

    Many S+S sensors are calibratable. Manual offset adjustment is often possible via a potentiometer on the circuit board (e.g., ±50 hPa for pressure sensors) or through Modbus register settings, depending on the specific device model.

  • Where can I find configuration software for RYMASKON controllers?

    Configuration tools for RYMASKON products are typically available for download on the official S+S Regeltechnik website. These tools allow for easy connection via USB to adjust firmware, Modbus registers, and time programs.

  • What are the default bus parameters for the Modbus gateway?

    For many S+S gateways, the factory default bus parameters are often set to 19200 baud, 8E1 (Even Parity, 1 Stop Bit), with bus termination deactivated. Always verify with the specific device datasheet.

  • Do S+S Regeltechnik sensors require a specific power supply?

    Most devices accept 24 V AC or 15-36 V DC. However, specifics vary by model (e.g., controllers may accept 100-240 V), so checking the technical data on the device label is essential before connection.