Carrier XT-LB i-Vu Building Automation System
Specifications
- BACnet Support: BACnet/IP, BACnet MS/TP
- Communication Ports: Gig-E, Port S1, Port S2
- Protection: Fire-retardant plastic ABS, UL94-5VA
- Integration: N2 Open, KNX, SNMP
- Real Time Clock: Yes, up to 3 days backup
- LED Status Indicators: Tricolour NET, Tricolour SYS, TX/RX LEDs
- Router Addressing: Rotary DIP switches
- Physical Dimensions:
- Overall: A – 7.1 in., B – 6.95 in., C – 6.45 in., D – 4.1 in.
- Mounting: DIN rail mount or screw mount
- Depth: 2.09 in., Weight: 1.1 lbs.
Product Usage Instructions
Installation
- Ensure power supply meets requirements.
- Mount the XT-LB unit using DIN rail or screw mount.
- Connect the unit to the Ethernet LAN using appropriate cables.
- Set the router address using the rotary DIP switches.
Configuration
- Access the i-Vu web server to configure the XT-LB unit.
- Add and configure devices connected under the XT-LB, including i-Vu and third-party devices.
- Integrate with other protocols such as N2 Open, KNX, and SNMP if required.
Maintenance
- Regularly check the LED status indicators for system and network status.
- Ensure the real-time clock is functioning correctly, especially after power failures.
- Keep the unit clean and free from dust or debris.
INTRODUCTION
- The i-Vu XT BACnet Link allows you to integrate other manufacturers’ equipment into the i-Vu building automation system using various protocols, making it easy to tie in equipment such as VFDs, boilers, and lighting systems.
- It supports integration via BACnet, Modbus, N2 Open, KNX, M-Bus, and SNMP protocols, enabled by the gen5 driver. Each i-Vu XT BACnet Link supports up to 1,500 third-party BACnet points and up to 500 Flex points for any protocol.
- The system can be expanded with Gen5 point packs to support up to 5,000 Flex points.
- The i-Vu XT BACnet Link also routes BACnet messages between the i-Vu building automation system backbone (BACnet/IP) and a subnetwork of i-Vu controllers (BACnet MS/TP).
- It connects directly to the Ethernet LAN and provides the i-Vu web server with access to the controller and any devices connected under that XT-LB, which can include a mixture of i-Vu and third-party devices.
Building Automation System
The i-Vu® Building Automation System
- VFDs
- Boilers
- Lighting
Specifications
BACnet Support | Conforms to the BACnet Building Controller (B-BC), BACnet Router (B-RTR), and BACnet BBMD (B-BBMD) device profiles as defined in BACnet 135-2012 Annexe L, Protocol Revision 19 |
Power Requirements | 24 VAC ± 10%, 50-60Hz, 50 VA
26 VDC ± 10%, 15W |
Communication Ports | Gig-E: 10/100/1000 BaseT Ethernet port for BACnet/IP, BACnet/Ethernet, BACnet/SC, and/or Modbus/IP networks
Port S1: High-speed EIA-485 port for connecting one of the following network types: BACnet MS/TP or Modbus RTU network at 9.6, 19.2, 38.4, 57.6, 76.8, 115.2 kbps Port S2: Electrically EIA-485 port for connecting BACnet MS/TP or Modbus RTU network at 9.6, 19.2, 38.4, 57.6, 76.8, 115.2 kbps S1 and S2 end-of-net switches can be turned on to terminate the network segment Local Access: 10/100 Base T Ethernet port for system start-up and troubleshooting. |
Protection | Device is protected by a replaceable, fast-acting, 250 Vac, 2A, 5 mm x 20 mm glass fuse. The power and network ports comply with the EMC requirements EN50491-5-2. |
Integration | Maximum 1500 third-party BACnet points (BACnet/IP, BACnet MS/TP) and up to 500 Flex points (expand- able to 5000 with Gen5 point packs) using Modbus/IP or Modbus RTU protocols. Supports integration with N2 Open, KNX, and SNMP protocols. |
Real Time Clock | Real-time clock keeps track of time in the event of a power failure for up to 3 days. |
LED Status Indicators | Tricolor NET LED to show network status, Tricolour SYS LED to show system status
A TX (Transmit) and RX (Receive) LED for the following ports: Gig-E, Port S1, and Port S2. |
Router Addressing | Rotary DIP switches set the address of the router |
Compliance | United States: FCC compliant to Title CFR47, Part 15, Subpart B, Class A; UL Listed, File E143900; CCN PAZX, UL 916, Energy Management Equipment; ANZ: RCM Mark AS/NZS 61000-6-3; Canada: UL Listed File E143900, CCN PAZX7, CAN/CSA C22.2 No. 205 Signal Equip., Industry Canada Compliant ICES-003, Class A; CE Mark Compliant with 2014/30/EU, and RoHS Compliant: 2015/863/EU; UKCA Mark compliant with Electromagnetic Compatibility Regulations 2016 – Gov.UK and and RoHS for Electrical and Electronic Equipment 2012. |
Environmental Operating Range | Operating: 32 to 140ºF (-18 to 60ºC); 10 to 90% RH, non-condensing
Storage: -24 to 140ºF (-30 to 60ºC); 10 to 90% RH, non-condensing |
Physical | Fire-retardant plastic ABS, UL94-5VA |
Dimensions
- Overall
- A: 7.1 in. (18.03 cm)
- B: 6.95 in. (17.65 cm)
- Mounting
- DIN rail mount or screw mount
- C: 6.45 in. (16.38 cm)
- D: 4.1 in. (10.4 cm)
- Depth: 2.09 in. (5.31 cm)
- Weight: 1.1 lbs. (.482 kg)
For more information
- For more information, contact your local Carrier Controls Expert.
- Controls Expert Locator: www.carrier.com/controls-experts
- ©Carrier 2025. All Rights Reserved. Cat. No. 11-808-617-01 Rev. 7/25
- The manufacturer reserves the right to discontinue or change at any time specifications or designs, without notice and without incurring obligations.
- Trademarks are properties of their respective companies and are hereby acknowledged.
FAQ
- Q: How many third-party BACnet points can the XT-LB support?
- A: The XT-LB can support a maximum of 1500 third-party BACnet points (BACnet/IP, BACnet MS/TP) and up to 500 Flex points (expandable to 5000 with Gen5 point packs).
- Q: What is the backup time of the real-time clock in case of a power failure?
- A: The real-time clock can keep track of time in the event of a power failure for up to 3 days.
- Q: How can I locate a Carrier Controls Expert for more information?
- A: You can visit www.carrier.com/controls-experts to find a Controls Expert near you.