EARU EARU1036

EARU 32A Circuit Breaker Instruction Manual

Model: EARU1036

1. Producte acabatview

The EARU 32A Circuit Breaker (Model EARU1036) is an Advanced Protection Suite (APS) designed to safeguard electrical circuits, appliances, and personnel. It integrates multiple protection functions into a single device, ensuring comprehensive safety and reliability for various electrical installations.

Característiques principals:

2. Informació de seguretat

Please read all safety instructions carefully before installing, operating, or maintaining this device. Failure to follow these instructions may result in electrical shock, fire, serious injury, or death.

3. Product Components and Wiring Diagram

Familiarize yourself with the main components and the correct wiring configuration of the EARU 32A Circuit Breaker.

Detallada view of EARU 32A Circuit Breaker components and wiring diagram

Imatge 1: Detallada view of the EARU 32A Circuit Breaker, highlighting its terminals, operating handle, test button, wiring diagram, surge protection indicator, reset button, fastening screws, and flame retardant housing. The diagram shows connections for Line (L), Neutral (N), and Protective Earth (PE). It emphasizes that the circuit must be wired and grounded correctly to ensure proper operation and protection.

Product Dimensions and Parameters

Dimensions and key parameters of EARU 32A Circuit Breaker

Imatge 2: This image displays the physical dimensions of the EARU 32A Circuit Breaker (94mm height, 71mm width, 45mm depth) and lists key product parameters such as Product Series (EADZ47L-32SVP), Rated Voltage (AC230V), Mechanical Lifespan (20000 cycles), Compliance Standard (IEC61009-1), Rated Residual Operating Current (30mA), Poles (2P+PE/4Pole), Product Certification (CE), and Breaking Capacity (6000A). It also highlights advanced features like overload, short circuit, lightning, leakage, over-undervoltage protection, smart reset, and real-time monitoring.

4. Instal·lació

The EARU 32A Circuit Breaker is designed for DIN-rail mounting. Ensure the installation environment is dry, well-ventilated, and free from corrosive substances.

Passos d'instal·lació:

  1. Muntatge: Securely attach the circuit breaker to a standard DIN rail in your electrical panel.
  2. Connexions de cablejat: Consulteu Imatge 1 for the wiring diagram. Connect the incoming Line (L) and Neutral (N) wires to the top terminals and the outgoing load wires to the bottom terminals. Ensure the Protective Earth (PE) is correctly connected.
  3. Ajustament de terminals: Use appropriate tools to tighten all fastening screws on the terminals to ensure secure electrical contact and prevent loose connections, which can cause overheating or arcing.
  4. Verificació: Double-check all wiring connections for correctness and tightness before restoring power.
EARU Circuit Breaker installed in an electrical panel

Imatge 3: An EARU Circuit Breaker installed on a DIN rail within an electrical panel, demonstrating a typical installation scenario with connected wiring.

5. Instruccions de funcionament

Basic Operation and Leakage Protection Test

Follow these steps for normal operation and to periodically test the leakage protection function of your circuit breaker.

Instructions for powering on and testing leakage protection

Imatge 4: This image illustrates the basic operating instructions. Pas 1: To power on, pull up the operating handle (red switch) and ensure the 'R' button is protruding, indicating a power-on state. Pas 2: If the handle jumps down automatically and the 'R' button bounces, it signifies a normal power-off state. Pas 3: If the 'R' button is pressed and the handle does not jump down, it indicates a problem. Pas 4: After a successful test or reset, the device returns to a powered-on state.

Detailed instructions for leakage protection device inspection

Imatge 5: Detailed instructions for inspecting the leakage protection device. Pas 1: With the operating handle pulled up and the 'R' button not protruding (power-on state), press the 'Test' key to test the leakage protection device. Pas 2: If the handle jumps down automatically and the 'R' button bounces, the device is in a power-off state, indicating the leakage protection device is functioning normally. Pas 3: If the 'Test' switch is pressed and the handle does not jump down, and the 'R' button does not automatically pop up, the device is in an energized state, indicating a problem with the leakage protection device, and it cannot provide protection. A new leakage device needs to be replaced. Pas 4: After a normal inspection (handle automatically jumps down, 'R' button automatically pops up), the device is in a power-off state. Press the 'R' button that just popped up, and then pull up the operating handle to power on the appliance normally.

Parameter Setting (Adjustable Voltage and Current Protector)

The EARU Circuit Breaker allows for adjustment of various protection parameters. The following video demonstrates how to set these parameters.

Vídeo 1: This video demonstrates how to adjust the protection parameters on an EARU Adjustable Voltage and Current Protector. It shows setting the overvoltage (P-1, range 240-300V), undervoltage (P-2, range 140-200V), overcurrent (P-3, range 1A-40A/63A/80A), reset/start delay (P-4, range 1s-300s), and relay recovery delay (P-5, range 1s-300s) settings. The video also shows the overcurrent recovery delay (P-6, range 1s-300s). This process involves pressing the 'SET' button to enter programming mode and using the up/down arrows to adjust values.

6. Manteniment

Regular maintenance ensures the longevity and reliable operation of your EARU Circuit Breaker.

7. Solució De Problemes

If you encounter issues with your EARU Circuit Breaker, refer to the following common troubleshooting steps. For complex problems, contact a qualified electrician.

ProblemaCausa possibleSolució
El dispositiu no s'encénIncorrect wiring; No input power; Device faultCheck wiring connections (L, N, PE); Verify main power supply; If wiring and power are correct, device may be faulty and require replacement.
Frequent tripping (Over-Voltage/Under-Voltage)Unstable power supply; Incorrect voltagConfiguracióComproveu la línia entrant voltage stability; Adjust over/under voltage settings (refer to Parameter Setting video) if necessary, ensuring they are within safe operating limits for your appliances.
Frequent tripping (Overload/Short Circuit)Excessive load; Short circuit in connected appliance/wiringReduce connected load; Inspect appliances and wiring for short circuits; Adjust overcurrent settings (refer to Parameter Setting video) if appropriate for the load, but do not exceed device rating.
Frequent tripping (Earth Leakage/Electric Shock)Ground fault in connected appliance/wiring; Device faultInspect appliances and wiring for ground faults; Perform leakage protection test (refer to Operating Instructions); If test fails and no external fault is found, device may be faulty.
Leakage protection test fails (handle does not jump down)Leakage protection mechanism faultThe leakage protection device is faulty and cannot provide protection. It must be replaced immediately.

8. Especificacions tècniques

Key technical specifications for the EARU 32A Circuit Breaker, Model EARU1036.

EspecificacióValor
MarcaEARU
Número de modelEARU1036
Valoració actual30 milionsamps (Residual Operating Current)
Voltage230 Volts
Wattage10000 watts
Dimensions del producte (P x A x A)20P x 12A x 12H centímetres
Tipus d'interruptorRCBO, RCCB, ELCB, MCB, Surge Protector
Tipus de muntatgeMuntatge sobre carril DIN
Nombre de pols6 (Implied from 2P+PE/4Pole in image, actual product is 2-pole with earth protection)
Pes de l'article450 g
Font d'alimentacióAlimentat per corrent altern
Components inclosos2 IN ONE (Circuit Breaker)
País d'origenÍndia
Data de primera disponibilitat10 de novembre de 2022

9. Garantia i Suport

The EARU 32A Circuit Breaker comes with a 2-year warranty, backed by GE-authorized service. For warranty claims, technical assistance, or product support, please contact your retailer or the authorized service center.

Fabricant: EARU

Venedor: GE INDIA INC.

Si us plau, conserveu el comprovant de compra per validar la garantia.

Documents relacionats - EARU1036

Preview EARU EAL-2 Din Rail Circuit Breaker Instruction Manual
Instruction manual for the EARU EAL-2 series din rail circuit breaker, detailing its features, safety instructions, and product parameters for AC 2P 230V 4P 400V A Type RCBO RCCB MCB electronic residual current circuit breakers.
Preview EARU EAMPManual d'usuari del protector d'energia intel·ligent WiFi de la sèrie DW-TY-63 | Vol.tage, Corrent, Protecció contra fuites
Manual d'usuari complet per a l'EARU EAMPProtector d'energia intel·ligent WiFi sèrie DW-TY-63. Més informació sobre la instal·lació, les característiques, les especificacions tècniques, el control de l'aplicació i la resolució de problemes per a vol.tagprotecció contra e, corrent i fuites.
Preview EARU EAMPManual d'usuari del protector d'energia intel·ligent WiFi de la sèrie DW-TY-63
Manual d'usuari complet per a l'EARU EAMPDW-TY-63 series WiFi Smart Energy Protector, detailing features, installation, app connection, parameter settings, and troubleshooting. Covers over/under voltage, over current, leakage protection, energy monitoring, and remote control.
Preview Earu EAMPManual d'usuari del protector d'energia intel·ligent WiFi de la sèrie DW-TY-63
Manual d'usuari i especificacions tècniques de l'Earu EAMPProtector d'energia intel·ligent WiFi sèrie DW-TY-63, que detalla la instal·lació, la connexió de l'aplicació, la configuració dels paràmetres i les funcions de seguretat.
Preview EARU-X6/8 Metal LED Indicator Light Instruction Manual
User manual for EARU-X6/8 series Metal LED Indicator Lights, detailing safety instructions, warnings, and product description for reliable status indication in industrial and traffic applications.
Preview EARU KR0548-CH WiFi Smart Automatic Transfer Switch (ATS) User Manual
User manual for the EARU KR0548-CH WiFi Smart Automatic Transfer Switch (ATS). Learn how to install, connect, and operate the device using the EARU app for seamless switching between main and backup power sources.