CQR B07WWCXZC9

CQR Hold-up PA Double Push Panic Button User Manual

Model: B07WWCXZC9

1. Introducció

Aquest manual proporciona instruccions completes per a la instal·lació, el funcionament i el manteniment del CQR Hold-up PA Double Push Panic Button. This device is designed to provide a reliable and immediate alert in emergency situations, integrating seamlessly with compatible alarm control panels. It features a double-press activation mechanism and a key-reset function to prevent accidental activation and ensure secure operation.

Si us plau, llegiu aquest manual detingudament abans de la instal·lació i l'ús per garantir-ne el funcionament i la seguretat adequats.

2. Informació de seguretat

  • Seguretat elèctrica: Installation should only be performed by qualified personnel in accordance with all local and national electrical codes. Ensure power to the alarm control panel is disconnected before wiring.
  • Muntatge: Mount the device securely on a stable surface to prevent accidental dislodgement.
  • Medi ambient: Do not expose the device to extreme temperatures, humidity, or direct water. It is designed for indoor use only.
  • Manteniment: No intenteu obrir ni reparar el dispositiu vosaltres mateixos. Envieu totes les tasques de manteniment a personal de servei qualificat.
  • Prova: Regularly test the panic button's functionality in conjunction with your alarm system to ensure it is operating correctly.

3. Contingut del paquet

Verifiqueu que tots els elements que s'enumeren a continuació siguin presents al vostre paquet:

  • CQR Hold-up PA Double Push Panic Button Unit
  • Key for Reset Function
  • Mounting Screws (may vary)
  • Aquest manual d'usuari
CQR Hold-up PA Double Push Panic Button with key
Figure 3.1: The CQR Hold-up PA Double Push Panic Button, showing the two red push buttons, the keyhole for reset, and the included black reset key.
Close-up of the panic button reset key
Figura 3.2: Un primer pla view of the metallic key used to reset the panic button after activation.
Product packaging for CQR Double Push PA
Figure 3.3: The product packaging, displaying the "DOUBLE PUSH PA" label and a barcode.

4. Configuració i instal·lació

The CQR Hold-up PA Double Push Panic Button is designed for surface mounting and integration with a compatible alarm control panel.

4.1. Ubicació de muntatge

Choose a discreet yet easily accessible location for mounting, such as under a counter, desk, or near a point of sale. Ensure the surface is clean, dry, and structurally sound.

4.2. Wiring to Alarm Control Panel

  1. Desconnecteu l'alimentació: Before beginning any wiring, ensure the alarm control panel is completely powered off and disconnected from its main power source and backup battery.
  2. Terminals de cablejat d'accés: Obriu el casing of the panic button (if applicable) to expose the wiring terminals. Refer to your alarm control panel's manual for specific zone input terminals for panic devices.
  3. Connecteu els cables: Connect the panic button's output wires to the designated panic zone input terminals on your alarm control panel. This device typically operates as a Normally Closed (NC) contact, opening upon activation. Consult the wiring diagram provided with your alarm control panel for correct polarity and connection points.
  4. Cablejat segur: Assegureu-vos que totes les connexions dels cables estiguin segures i correctament aïllades.
  5. Tanca Casing: Carefully close the panic button casing.

4.3. Muntatge de la unitat

  1. Marca els forats: Use the panic button unit as a template to mark the drilling locations for the mounting screws on your chosen surface.
  2. Perforar forats pilot: Drill pilot holes if necessary, appropriate for the mounting screws.
  3. Dispositiu segur: Align the panic button with the drilled holes and secure it firmly using the provided mounting screws. Do not overtighten.

4.4. Engegar i provar

Once installation is complete, restore power to the alarm control panel. Perform a functional test of the panic button as described in the "Operating Instructions" section to ensure it triggers the alarm system correctly.

5. Instruccions de funcionament

5.1. Activating the Panic Button

To activate the panic alarm, simultaneously press both red push buttons on the front of the unit. The double-press mechanism is designed to minimize accidental activations while ensuring quick response in an emergency.

Upon successful activation, the panic button will latch, and the alarm control panel will initiate the programmed panic response (e.g., siren activation, silent alarm, notification to monitoring station).

5.2. Resetting the Panic Button

After activation, the panic button will remain in a latched state until manually reset. To reset the device:

  1. Insert the provided key into the keyhole located on the top surface of the panic button.
  2. Turn the key clockwise (or counter-clockwise, depending on the specific mechanism) until the buttons release and return to their original position.
  3. Remove the key. The panic button is now reset and ready for re-activation.

Important: Always keep the reset key in a secure and accessible location known only to authorized personnel.

6. Manteniment

The CQR Hold-up PA Double Push Panic Button requires minimal maintenance to ensure reliable operation.

  • Neteja: Periodically wipe the exterior of the unit with a soft, dry cloth. Do not use abrasive cleaners, solvents, or excessive moisture.
  • Prova: It is recommended to test the panic button's functionality at least once a month to confirm its connection to the alarm system and proper activation/reset.
  • Inspecció: Visually inspect the unit for any signs of damage, loose wiring, or tamperrant.

7. Solució De Problemes

If you encounter issues with your CQR Hold-up PA Double Push Panic Button, refer to the following common problems and solutions:

ProblemaCausa possibleSolució
Panic button does not activate alarm.
  • Incorrect wiring to alarm panel.
  • Connexions de cable soltes.
  • Alarm panel zone not properly configured.
  • Mal funcionament del dispositiu.
  • Verify wiring against alarm panel manual.
  • Comproveu i fixeu totes les connexions dels cables.
  • Consult alarm panel manual for zone programming.
  • Contact qualified service personnel if issue persists.
Panic button does not reset with key.
  • Key not fully inserted or turned correctly.
  • Obstrucció o dany del mecanisme intern.
  • Ensure key is fully inserted and turned firmly.
  • Do not force the key. If still stuck, contact service personnel.
Accidental activations.
  • Improper mounting location.
  • Obstrucció física.
  • Relocate the device to a less prone area.
  • Assegureu-vos que no hi hagi objectes que pressionin els botons.

If the problem persists after attempting these solutions, please contact your alarm system installer or the manufacturer's technical support.

8. Especificacions

CaracterísticaDetall
ModelHold-up PA Double Push
ASINB07WWCXZC9
MarcaCQR
FabricantSecurity Components LTD
ColorBlanc
Tipus d'activacióDouble Press Latching
Mecanisme de restablimentRestabliment de claus
CompatibilitatUniversal operation with Alarm control panel
Data de primera disponibilitat22 d'agost de 2019

9. Garantia i Suport

Specific warranty information for the CQR Hold-up PA Double Push Panic Button is not provided within this manual. For details regarding warranty coverage, terms, and conditions, please refer to the documentation included with your purchase or contact the retailer or manufacturer directly.

For technical support, installation assistance, or troubleshooting beyond the scope of this manual, please contact your alarm system installer or the manufacturer, Security Components LTD, through their official channels.

You can visit the CQR Store on Amazon for more information: CQR Store

Documents relacionats - B07WWCXZC9

Preview Botons de pànic CQR: comprensió i especificacions
Acabat integralview de botons de pànic CQR, detallant tipus, característiques, graus de seguretat i especificacions tècniques per a aplicacions domèstiques i comercials.
Preview CQR Panic Buttons: Understanding and Product Specifications
A comprehensive guide to CQR panic buttons, detailing their functionality, types (mechanical, electronic, single/double push, confirmed), reset methods, fitting options, and finishes. Includes detailed product specifications and comparisons for the PASP, PADP, and EPA ranges.
Preview Puntador de trucada manual i dispositius de seguretat CQR FP3 | Informació tècnicaview
Detall tècnicview del pulsador manual FP3 de CQR, amb configuracions unipolars i bipolars, certificació EN54-11 i altres productes de seguretat, com ara botons d'atac personal, pulsadors FP2, caixes de connexions i caixes buides.
Preview Dispositiu de retenció de la sèrie CQR PADP3: Instruccions d'ús i instal·lació
Guia completa per a la instal·lació i el funcionament del dispositiu antirobatori CQR de la sèrie PADP3, que cobreix la configuració, les especificacions i les característiques dels sistemes de seguretat.
Preview CQR PADP2 Grade 1: Double Push Hold Up Device | Security Solutions
Explore the CQR PADP2 Grade 1 Double Push Hold Up Device. This brochure details its features, technical specifications, product codes, and compliance with PD6662:2010 for reliable security applications.
Preview CQR Security Intruder Detection Systems Product Catalog
Comprehensive product catalog from CQR Security detailing intruder detection systems, including a wide range of cables, magnetic contacts, sounders, shock sensors, hold-up devices, call points, power supplies, junction boxes, exit buttons, and 12V fire detectors for security applications.