Atlas AWM2

Atlas WeatherMaster Ice and Water Roof Underlayment

Model: AWM2

Producte acabatview

The Atlas WeatherMaster Ice and Water Roof Underlayment is a self-adhesive membrane designed to provide a critical secondary layer of waterproofing protection for roofing systems. It effectively prevents damage caused by ice dams and wind-driven rain, enhancing the longevity and integrity of the roof structure.

Composed of a proprietary SBS-modified asphalt, this underlayment offers excellent traction during installation and robust protection against UV degradation and weathering. Its high-temperature stability makes it suitable for various roofing applications, including new construction and re-roofing projects requiring a complete tear-off.

Característiques clau

  • Superior Adhesion: Offers 2x more adhesion than industry standard products, ensuring a secure bond to the roof deck.
  • Self-Adhering Design: Features a self-adhesive backing that seals directly to the deck, eliminating the need for special adhesives, equipment, or heat for installation.
  • Enhanced Strength: Incorporates a fiberglass mat for increased strength and better tear resistance compared to traditional saturated felt.
  • Rendiment a baixa temperatura: Maintains an aggressive bond even at low temperatures, with a minimum application temperature of 45 degrees Fahrenheit.
  • Optimal Thickness: With a 55-mil thickness, it exceeds industry requirements by 38%, providing robust protection.
  • Cobertura: Each roll covers 2 squares (200 square feet), with dimensions of 36 inches in width and 65 feet in length.

Instal·lació i Configuració

Proper installation of the Atlas WeatherMaster Ice and Water Underlayment is crucial for its performance. This self-adhering membrane simplifies the process, requiring no special tools or heating.

Preparació:

  • Ensure the roof deck is clean, dry, and free of debris.
  • Verify that the deck material is code-approved.
  • The minimum application temperature is 45 degrees Fahrenheit (7 degrees Celsius).

Àrees d'aplicació:

This underlayment is designed for critical areas of the roof where water and ice accumulation are most likely to occur. Apply to:

  • Valls
  • ràfecs
  • Intermitents
  • Hips and Ridges
  • Raclets
  • Around dormers and skylights

Passos d'instal·lació (directrius generals):

  1. Eave Edge Application: Begin by applying the WeatherMaster Ice & Water underlayment at the eave edge. Ensure the flashing membrane overhangs the drip edge by 1/4 to 3/4 inch at the eaves.
  2. Nailing: Secure the underlayment with nails 12 inches on center (O.C.) at the eave edge on wood decks.
  3. Interior Wall Line Coverage: Apply the underlayment to a point at least 24 inches beyond the interior wall line to provide adequate protection against ice damming.
  4. Rake Edge Application: At the rake edge, the drip edge should be installed over the WeatherMaster Ice & Water underlayment.
  5. Superposició: Ensure a 3-inch overlap for subsequent courses of underlayment to maintain continuous waterproofing.
  6. Adhesió: The self-adhesive backing will bond aggressively to the deck. Roll or press firmly to ensure full contact and remove any air bubbles.
Diagram showing the application of WeatherMaster Ice & Water underlayment on a roof section, detailing drip edge placement, overlaps, and nailing patterns.

Figure 1: WeatherMaster Ice & Water Field Application Diagram. This illustration demonstrates the proper placement and overlapping techniques for the underlayment at eaves, rakes, and interior wall lines, including drip edge and nailing details.

Roll of Atlas WeatherMaster Ice and Water Roof Underlayment, partially unrolled to show the black asphalt surface and the protective film.

Figure 2: Atlas WeatherMaster Ice and Water Roof Underlayment Roll. This image displays a roll of the underlayment, partially unrolled to reveal its self-adhesive asphalt surface and the protective film that is removed during installation.

Característiques de rendiment

Once installed, the Atlas WeatherMaster Ice and Water Underlayment functions as a robust, passive barrier against water intrusion. Its primary role is to provide a secondary waterproofing layer beneath the primary roofing material.

  • Ice Dam Protection: Effectively prevents water from entering the structure due to ice damming, where melting snow refreezes at the eaves.
  • Wind-Driven Rain Barrier: Acts as a seal against wind-driven rain that might penetrate the primary roof covering.
  • Self-Sealing Around Fasteners: The SBS-modified asphalt composition allows the membrane to self-seal around roofing fasteners, further enhancing its waterproofing capabilities.
  • Compatibilitat: Provides extra protection under various roofing types, including tile, wood shake, asphalt shingles, slate, or metal.
  • Classificació de foc: Achieves Underwriters Laboratories Class A and Class C Fire Ratings (based on the roof covering system).
  • Certificacions: Complies with ASTM D1970 (Standard Ice Dam Underlayment), Florida Building Code Approved (FL 17322), and Miami-Dade County Product Control Approved.

Manteniment

The Atlas WeatherMaster Ice and Water Underlayment is designed to be a maintenance-free component of your roofing system once properly installed. Its durable composition and self-sealing properties ensure long-term performance without requiring regular upkeep.

Periodic inspection of the overall roofing system is recommended to identify any potential issues with the primary roof covering that could expose the underlayment to prolonged UV or physical damage. Any damage to the primary roof should be addressed promptly to maintain the integrity of the entire system.

Resolució de problemes

While the WeatherMaster underlayment is designed for reliable performance, issues can sometimes arise, primarily related to installation or extreme conditions. Below are common concerns and potential solutions:

Issue: Poor Adhesion During Installation

Possible causa: Application temperature below 45°F (7°C), dusty or wet roof deck, or insufficient pressure applied during installation.

Solució: Ensure the roof deck is clean, dry, and within the recommended temperature range. Apply firm, even pressure across the entire surface of the membrane using a roller to ensure full contact and activate the adhesive. Do not install on frozen or contaminated surfaces.

Issue: Wrinkling or Buckling After Installation

Possible causa: Trapped air or moisture beneath the membrane, or improper tension during application.

Solució: During installation, carefully unroll the membrane, avoiding wrinkles. Use a roller to smooth out any trapped air immediately. If buckling occurs after installation, it may indicate moisture issues or improper deck preparation. Consult a roofing professional for assessment.

Issue: Water Leaks Despite Underlayment Installation

Possible causa: Damage to the underlayment during subsequent roofing work, improper overlaps, or issues with the primary roofing material.

Solució: The underlayment is a secondary barrier. First, inspect the primary roofing material (shingles, tiles, etc.) for damage or improper installation. If the underlayment itself is suspected, a professional inspection is required to identify and repair any breaches or improper sealing points. Ensure all overlaps are correctly sealed and that the membrane extends sufficiently into critical areas.

Especificacions

AtributDetall
FabricantAtles
Número de modelAWM2
MaterialAsphalt and Fiberglass
Item Weight (Pallet)1655 lliures
Quantitat de paquet d'articles25 rotllos
Roll Coverage2 Square (200 Square Feet) per roll
Roll Dimensions36 inches (Width) x 65 feet (Length)
Gruix55 mil
Minimum Application Temperature45 °C (7 °F)
CertificacionsUL Class A and C Fire Rating, ASTM D1970, Florida Building Code Approved (FL 17322), Miami-Dade County Product Control Approved

Informació de la garantia

Specific warranty details for the Atlas WeatherMaster Ice and Water Roof Underlayment are typically provided by the manufacturer at the time of purchase or can be found on the official Atlas website. It is recommended to retain your purchase receipt and any warranty documentation provided with the product.

For the most accurate and up-to-date warranty terms, including coverage duration and conditions, please refer to the official documentation from Atlas or contact their customer service directly.

Atenció al client

For technical assistance, installation guidance, or any product-related inquiries regarding the Atlas WeatherMaster Ice and Water Roof Underlayment, please contact Atlas customer support.

While specific contact details are not provided in this manual, you can typically find comprehensive support resources, including FAQs, technical data sheets, and contact information, on the official Atlas website. Please have your product model number (AWM2) and any relevant purchase details ready when contacting support.

Documents relacionats - AWM2

Preview Atlas Premier SD70ACe Diesel Locomotive Owner's Manual - Operation and Maintenance Guide
This owner's manual provides comprehensive instructions for operating, maintaining, and troubleshooting the Atlas Premier SD70ACe Diesel Locomotive with Proto-Sound® 3.0. Learn about setup, conventional and digital control modes, sound features, and more.
Preview Assembly Instructions for Atlas Queen Bed DLB2302B-QHB/FB
Detailed assembly instructions for the Atlas Queen Bed model DLB2302B-QHB/FB, including parts list and step-by-step guidance for a safe and stable setup.
Preview Atlas PV-12PX Two-Post Overhead Lift Installation and Operation Manual
This manual provides detailed instructions for the installation, operation, and maintenance of the Atlas PV-12PX 12,000 lb. capacity two-post overhead vehicle lift. Learn about product features, specifications, and troubleshooting.
Preview Atlas 4000 lb ATV/UTV Electric Winch: Owner's Manual & Operating Instructions
Comprehensive guide for the Atlas 4000 lb. 12V DC electric winch for ATVs and UTVs, covering installation, operation, safety, maintenance, and technical specifications.
Preview Atlas 90HSC Two-Post Overhead Lift Installation and Operation Manual
Comprehensive guide for the installation, operation, and maintenance of the Atlas 90HSC 9,000 lb. capacity two-post overhead lift. Includes specifications, safety instructions, troubleshooting, and parts list.
Preview Atlas VISTA Vertical Platform Lift Installation Guide - Safety & Setup
Detailed installation guide for the Atlas VISTA Vertical Platform Lift. Learn about safety features, technical specifications, and step-by-step assembly for residential and commercial use. Visit atlasacces.com for more.