SurgeX SX-20NE-RT

Manual d'usuari del condicionador de corrent supressor de sobretensions de grau industrial SurgeX SX20 NE/RT

1. Introducció

This manual provides detailed instructions for the installation, operation, and maintenance of the SurgeX SX20 NE/RT Industrial Grade Surge Suppressor Power Conditioner. The SX20 NE/RT is designed to protect sensitive electronic equipment from power surges and electrical disturbances, ensuring reliable performance and longevity of connected devices. Please read this manual thoroughly before installation and operation to ensure proper use and safety.

2. Informació de seguretat

Adherence to the following safety precautions is essential to prevent injury and damage to the unit or connected equipment.

3. Producte acabatview

The SurgeX SX20 NE/RT is a robust 20-amp surge suppressor and power conditioner housed in a magnetic shielding NEMA steel enclosure. It features True Series Mode technology for superior surge protection and EMI/RFI filtering. The unit also includes remote turn-on capabilities and a self-test circuit with visual indicators.

Característiques clau

Davant view of the SurgeX SX20 NE/RT surge suppressor and power conditioner, showing the brand logo, model number, indicator lights for REMOTE and SELF-TEST, and the A-1-1 certification.

Figure 1: SurgeX SX20 NE/RT Front Panel
This image displays the front panel of the SurgeX SX20 NE/RT unit. Visible elements include the SurgeX logo, 'True Series Mode' and 'Industrial Grade Surge Suppressor Power Conditioner' text, and the model number 'SX20 NE/RT'. Two indicator lights are present: a yellow 'REMOTE' light and a green 'SELF-TEST' light. A circular red-outlined opening is also visible on the lower right side of the front panel. The unit is housed in a grey metallic enclosure with multiple knock-outs on the top and right sides for wiring.

4. Configuració i instal·lació

The SurgeX SX20 NE/RT is designed for hardwired installation. Ensure all power is disconnected before proceeding.

4.1 Desembalatge

Carefully remove the unit from its packaging. Inspect for any signs of shipping damage. Report any damage to your supplier immediately.

4.2 Muntatge

Mount the NEMA enclosure securely to a wall or suitable surface using appropriate fasteners. Ensure adequate ventilation around the unit.

4.3 Connexions de cablejat

The unit features a barrier strip accessible through knock-outs for hardwiring power input and output connections. Follow these steps:

  1. Select appropriate knock-outs for incoming and outgoing power cables.
  2. Route the 120V AC input power cable to the designated input terminals on the barrier strip.
  3. Route the output power cable(s) for the protected equipment to the designated output terminals.
  4. Ensure all connections are secure and properly torqued according to electrical code requirements.
  5. Verify correct polarity (Line, Neutral, Ground) for all connections.

4.4 Remote Turn-On Connection

The SX20 NE/RT supports remote turn-on and turn-off. A separate terminal block within the enclosure is provided for this functionality. Connect a contact closure or an applied DC voltage source to activate the remote control feature. Refer to the wiring diagram provided with the unit for specific terminal assignments.

5. Instruccions de funcionament

Once installed and wired, the SurgeX SX20 NE/RT operates automatically to protect connected equipment.

5.1 Llums indicadors

El panell frontal inclou dos indicadors lluminosos:

5.2 Self-Test Function

The unit performs an automatic self-test upon power-up and continuously monitors its internal components. The green SELF-TEST indicator confirms proper operation. If this light is not illuminated, consult the troubleshooting section.

6. Manteniment

The SurgeX SX20 NE/RT requires minimal maintenance. Periodically inspect the unit and its connections for any signs of wear, damage, or loose wiring. Ensure the enclosure remains free of dust and debris. Do not use liquid cleaners directly on the unit. No internal user-serviceable parts are present.

7. Solució De Problemes

Consulteu la taula següent per veure els problemes habituals i les seves possibles solucions.

ProblemaCausa possibleSolució
No hi ha alimentació als equips connectats.No input power; tripped circuit breaker; faulty wiring.Check main power supply; reset circuit breaker; verify all wiring connections.
SELF-TEST indicator is off.Internal fault; unit not receiving power.Verify input power. If power is present and light remains off, contact SurgeX support.
REMOTE indicator is on, but unit does not turn on/off.Incorrect remote control signal; faulty remote connection.Verify remote control wiring and signal type (contact closure or DC voltagi).

8. Especificacions

Detailed technical specifications for the SurgeX SX20 NE/RT.

CaracterísticaEspecificació
Número de modelSX-20NE-RT
Entrada Voltage120 volts de corrent altern
Valoració de càrrega20 Amps
Tipus de tancamentMagnetic Shielding NEMA Steel Enclosure
Dimensions del producte (A x A x P)12.0 x 12.0 x 4.0 polzades
Pes de l'article14.47 lliures
Protecció contra sobretensionsTrue Series Mode, withstands 1000 occurrences of surge pulse voltages up to 6000 volts
FiltratFiltratge EMI/RFI
Control remotContact closure or applied DC voltage
FabricantSurgeX
Data de primera disponibilitat26 de juliol de 2010

9. Garantia i Suport

For information regarding the product warranty, please refer to the warranty card included with your SurgeX SX20 NE/RT or visit the official SurgeX website. For technical support, service, or replacement parts, please contact SurgeX customer service directly. Ensure you have your model number and purchase date available when contacting support.

Fabricant: SurgeX
Weblloc: www.surgex.com (Exampl'enllaç, si us plau, verifiqueu-ho oficialment weblloc)

Documents relacionats - SX-20NE-RT

Preview SurgeX CONNECT Quick Start Guide
Concise guide for setting up and connecting SurgeX CONNECT devices, including firmware updates, account creation, and network configuration.
Preview Guia d'inici ràpid de la PDU amb protecció contra sobretensions controlable per IP commutada SurgeX Axess+
Aquesta Guia d'inici ràpid proporciona informació essencial per instal·lar i configurar la unitat de distribució d'alimentació (PDU) protegida contra sobretensions controlable amb IP commutat SurgeX Axess+. Cobreix la identificació de la unitat, els procediments d'instal·lació del bastidor, les descripcions dels components i els mètodes per accedir a la web interfície. Els models compatibles inclouen SX-AP-129, SX-AP-169, SX-AP-109i i SX-AP-169i.
Preview Manual d'usuari de la PDU amb protecció contra sobretensions controlable per IP commutada SurgeX DisplayPak+
Manual d'usuari per a la sèrie SurgeX DisplayPak+ de PDU protegides contra sobretensions controlables per IP commutades, que detalla la instal·lació i la configuració mitjançant web servidor, gestió d'energia, funcions de seguretat, resolució de problemes i especificacions.
Preview Manual d'usuari de la utilitat d'actualització del firmware SurgeX Axess Elite
Aquest manual d'usuari proporciona instruccions per utilitzar la utilitat d'actualització SurgeX Axess Elite (AEUU) per gestionar i actualitzar el firmware dels dispositius SurgeX Axess Elite. Cobreix la instal·lació, la configuració de la xarxa, els requisits previs, les actualitzacions de firmware i operacions addicionals com ara aplicar la configuració. files i establint els valors predeterminats de fàbrica.
Preview Guia d'inici ràpid de SurgeX Axess Elite+ SX-AEP-209
Guia d'inici ràpid per a la unitat de distribució d'alimentació SurgeX Axess Elite+ SX-AEP-209, que cobreix la configuració, les connexions i web accés al navegador.
Preview Instruccions d'instal·lació i guia d'inici ràpid de la PDU intel·ligent SurgeX Vertical Series+
Comprehensive installation and quick start guide for the SurgeX Vertical Series+ Smart PDU. Covers safety precautions, inventory, physical connections, AC power, Ethernet, USB-OTG, LED indicators, button functions, and accessing the web interface for setup and configuration.