1. Proizvod je gotovview
The Sicce Ultrazero Flat Sucking Pump is designed for efficient removal of water from various areas, including flooded cellars, garages, and other spaces where minimal residual water is desired. This submersible pump is capable of reducing water levels down to 2-3 mm.
Ključne karakteristike:
- Capable of pumping water down to 2 mm residual level.
- Fully submersible design.
- Handles dirt particles up to 3 mm in size.
- Equipped with a 10-meter power cable.
- Features a practical carry handle for easy transport.

Slika 1: Gotovoview of the Sicce Ultrazero Flat Sucking Pump.
2. Sigurnosne informacije
Read all safety warnings and instructions before operating the pump. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Always disconnect the pump from the power supply before handling, cleaning, or performing any maintenance.
- Osigurajte napajanje voltage matches the pump's specifications (230 V/50 Hz).
- Do not operate the pump with a damaged power cord or plug. If damaged, it must be replaced by the manufacturer, service agent, or similarly qualified persons to avoid a hazard.
- Do not use the pump to handle flammable or explosive liquids.
- Držite djecu i neovlaštene osobe dalje od radnog područja.
- Ensure the pump is fully submerged during operation to prevent overheating.
- Izbjegavajte rad pumpe na suho tokom dužeg perioda.
- This pump is designed for water only. Do not use it for other liquids without consulting the manufacturer.
3. Postavljanje i instalacija
Follow these steps to properly set up your Ultrazero pump:
- Raspakujte pumpu: Carefully remove the pump and all accessories from the packaging. Inspect for any damage.
- Connect the Discharge Hose:
The pump features a 26.44 mm (3/4") AG pressure connection. Attach a suitable discharge hose (e.g., 20 mm (3/4") hose connection) to this outlet. Ensure the connection is secure to prevent leaks.

Figure 2: Close-up of the pump's discharge outlet and integrated carry handle.
- Postavite pumpu: Place the pump directly on the surface from which water needs to be removed. Ensure the pump is stable and upright. The flat base allows for efficient water removal down to minimal levels.
- Route the Discharge Hose: Direct the discharge hose to a suitable drainage area, ensuring the water will not flow back into the area being drained.
- Priključak za napajanje: Plug the 10-meter power cable into a grounded 230 V/50 Hz electrical outlet. Ensure the outlet is protected by a Ground Fault Circuit Interrupter (GFCI) for added safety, especially in wet environments.

Figure 3: The flat base of the pump designed for low residual water levels.
4. Uputstvo za upotrebu
The Ultrazero pump is designed for simple operation:
- Potopite pumpu: Ensure the pump is fully submerged in the water you wish to remove. The pump requires water to cool its motor and operate correctly.
- Početak pumpanja: Once submerged and connected to power, the pump will begin operating automatically. It does not feature a float switch, so manual monitoring is required for optimal use.
- Pratite nivo vode: The pump will continue to operate until the water level reaches its minimum suction capability of 2-3 mm.
- Zaustavite pumpanje: To stop the pump, disconnect it from the power supply. It is recommended to disconnect the pump once the desired water level is reached or if the pump starts to run dry.

Figure 4: The Ultrazero pump effectively draining water from a small pool.

Figure 5: The pump in action on a flooded floor, demonstrating its low-level suction capability.

Figure 6: Illustration of the pump's ability to reduce water levels to approximately 2 mm.
5. Održavanje
Redovno održavanje osigurava dugotrajnost i optimalne performanse vaše pumpe.
- čišćenje: After each use, especially when pumping dirty water, rinse the pump thoroughly with clean water. This helps prevent sediment buildup.
- Pregledajte ima li krhotina: Periodically check the pump's intake area for any debris (e.g., leaves, small stones) that might obstruct water flow. Remove any blockages carefully after disconnecting power.
- Inspekcija kablova: Regularly inspect the power cable for cuts, abrasions, or other damage. Do not use the pump if the cable is damaged.
- Skladištenje: When not in use, store the pump in a clean, dry place, protected from frost.

Figure 7: The pump can also be used for transferring water for tasks like garden watering from a rain barrel.
6. Otkrivanje problema
If you encounter issues with your Ultrazero pump, refer to the following common problems and solutions:
| Problem | Mogući uzrok | Rješenje |
|---|---|---|
| Pumpa se ne pokreće. | Nema napajanja. Kabl za napajanje oštećen. Aktivirana je zaštita od preopterećenja motora. | Provjerite priključak za napajanje i utičnicu. Inspect cable for damage; replace if necessary (by qualified personnel). Disconnect power, allow motor to cool, then reconnect. |
| Pumpa radi, ali voda se ne ispušta. | Intake blocked. Ispusno crijevo je savijeno ili začepljeno. Airlock in pump. | Disconnect power, clear intake. Check and clear discharge hose. Briefly lift and lower the pump while submerged to release trapped air. |
| Smanjene performanse pumpanja. | Partial blockage. Impeller worn. | Disconnect power, clean pump intake and impeller area. Za servis kontaktirajte korisničku podršku. |
| Pumpa se neočekivano zaustavlja. | Overheating due to low water level or blockage. Električna greška. | Disconnect power, check water level and clear blockages. Allow to cool. Ako problem i dalje postoji, kontaktirajte korisničku podršku. |
If the problem persists after attempting these solutions, please contact Sicce customer support.
7. Tehničke specifikacije
Detailed specifications for the Sicce Ultrazero Flat Sucking Pump, Model 925607:
| Specifikacija | Vrijednost |
|---|---|
| Brand | Sicce |
| Broj modela | 925607 |
| Max. Delivery Rate (Flow Rate) | 3000 l/h |
| Maks. Visina isporuke | 3.1 m |
| Power Consumption (P1) | 80 W |
| Operating Voltage | 220-240V / 50Hz |
| Conductor Length (Power Cable) | 10 m (three-core, indoor and outdoor use) |
| Priključak pod pritiskom | 26.44 mm (3/4") AG |
| Prečnik priključka crijeva | 20 mm (3/4") |
| Max. Solids Size | 3 mm |
| Nivo preostale vode | Down to 2-3 mm |
| Dimenzije proizvoda (približno) | 140 mm (Diameter) x 160 mm (Height) / 5.5" x 6.3" |
| Težina artikla | 2.6 kg (5.72 lbs) |
| Prekidač plovaka | br |
| Zaštita od preopterećenja | No (Internal thermal protection may exist, but no external reset) |
| Porijeklo | Proizvedeno u Italiji |

Figure 8: Technical drawing illustrating the pump's dimensions and 3/4" GAS connection.
8. Garancija i podrška
For warranty information or technical support regarding your Sicce Ultrazero Flat Sucking Pump, please contact Sicce customer service. Keep your purchase receipt and model number (925607) handy when contacting support.
Proizvođač: Ebara
Brand: Sicce
For further assistance, visit the official Sicce webstranicu ili kontaktirajte svog lokalnog distributera.