This manual contains important information about the installation, operation, and maintenance of Bromic Semi Vertical Display units. Please pay close attention to the important safety information shown throughout this instruction manual. Any safety information will be accompanied by the following safety alert symbols:

DANGER, WARNING, IMPORTANT

  • READ THIS MANUAL CAREFULLY before installing or servicing this product.
  • Improper installation, operation, or maintenance can result in death, severe injury, or property damage.
  • Improper installation, operation, or maintenance may also result in warranty being voided.
  • This appliance is intended for 230-240 Volt power supply.
  • Installation MUST be carried out by a licensed and authorised technician in accordance with local electrical codes.
  • Installation and maintenance MUST be carried out as per instruction, by a qualified technician in accordance with local regulation.

IMPORTANT NOTES AND WARNINGS

  • Read all instructions before installing or using this appliance
  • Retain this manual for future reference
  • Use this appliance only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock or injury.
  • Improper installation, adjustment or alteration and failure to follow the warnings and instructions in this manual could result in severe personal injury, death or property damage
  • The manufacturer is not responsible for any damage that could happen from improper use. The manufacturer emphasises that this appliance should be used in a responsible manner and that all procedures, warnings, and safety instructions contained in this booklet be followed strictly.
  • Check the appliance for damage. Do not operate a damaged unit.
  • Check for damage to the appliance regularly. If damage to the appliance is suspected, discontinue use immediately and contact the supplier or qualified person to repair.
  • This appliance is not intended for use by people (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible of their safety.
  • Keep packaging material out reach of children
  • Children should be carefully supervised to ensure that they do not play with the appliance
  • Do not attempt to alter the appliance in any manner.
  • Please pay attention to the maximum load limit when filling the shelves.
  • All work on electrical equipment must be carried out by a qualified and licensed technician only.
  • Do not perform maintenance until the appliance has been turned off and power disconnected.
  • Never detach any cover except where specifically instructed in this manual. Doing so might expose live electrical parts.
  • Do not operate the appliance with panels, covers or guards removed.
  • Keep the air intake and outlets free of obstructions.
  • Do not use the appliance outdoors.
  • If the supply cord becomes damaged, it must be replaced by an authorised service agent or similarly qualified person in order to avoid a hazard.
  • If the appliance has not been used, or will not be used for a long period of time, disconnect power supply.
  • The appliance must be installed in accordance to AS1677.2:1998 to ensure there are no sources of ignition any area where refrigerant could gather in the event of a leak.
  • Electrical equipment should not be placed under the unit or where refrigerant could gather in the event of a leak.
  • Installation/servicing of the appliance must be performed by a licensed technician with Gas Work Authorization if the appliance gas system is being opened or charged.
  • The refrigerant used in all appliances covered by this manual are flammable.

BROMIC-REFREGERATION-SVM1875SD-NR-Semi-Vertical-Display-Fridge (2)

PACKAGING AND HANDLING

  • This Semi Vertical display contains fragile glass. The unit must always be handled with care.
  • Adjust the width of forklift tines such that they line up with the structural supports on the Semi Vertical unit before lifting.
  • The Semi Vertical unit must always be handled on flat and level ground.
  • Take care not to damage the castors, while inserting forklift tines into the pallet.

BROMIC-REFREGERATION-SVM1875SD-NR-Semi-Vertical-Display-Fridge (3)

PRODUCT OVERVIEW

SVM1000HD-NR SVM1250HD-NR SVM1580HD-NR SVM1875HD-NR SVM2500HD-NR
Part Number 3335639-NR 3335640-NR 3335643-NR 3335641-NR 3335642-NR
Height, mm 1500 1500 1500 1500 1500
External Dimension Width, mm 1022 1334 1580 1959 2584
Depth, mm 825 825 825 825 825
Volume Litres 332 443 559 664 885
Weight Kg 165 190 220 240 290
Air Circulation Type Fan Forced Fan Forced Fan Forced Fan Forced Fan Forced
Climate Class Rating 3M1 3M1 3M1 3M1 3M1
Range -1°C to +10°C -1°C to +10°C -1°C to +10°C -1°C to +10°C -1°C to +10°C
Temperature Type Digital Digital Digital Digital Digital
Exterior Material Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Interior Material Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Colour Default Black Black Black Black Black
Voltage, V 220-240V 220-240V 220-240V 220-240V 220-240V
Electrical Frequency, Hz 50 50 50 50 50
Current, A 2.52 2.53 1.48 3.60 3.66
Energy Consumption kWh/24h 2.6 3.1 4.1 4.6 6.9
Internal Light Type LED LED LED LED LED
Shelves Qty 3 plus base 3 plus base 3 plus base 3 plus base 3 plus base
Solid/Glass Glass Glass Glass Glass Glass
Door Style Hinged Hinged Hinged Hinged Hinged
Self-Closing Yes Yes Yes Yes Yes
Door Lock No No No No No
Door Swing Dimension mm 469 625 748 469 625
Total Depth of Door Open mm 1259 1415 1538 1259 1415
Refrigeration Refrigerant R290 R290 R290 R290 R290
Plug Supplied 10A 10A 10A 10A 10A
Location Rear Rear Rear Rear Rear
Cord Length, m 2 2 2 2 2
Castors Available Yes Yes Yes Yes Yes
SVM1000SD-NR SVM1250SD-NR SVM1580SD-NR SVM1875SD-NR SVM2500SD-NR
Part Number 3335639-NR 3335640-NR 3335643-NR 3335641-NR 3335642-NR
Height, mm 1500 1500 1500 1500 1500
External Dimension Width, mm 1022 1334 1580 1959 2584
Depth, mm 825 825 825 825 825
Volume Litres 332 443 559 664 885
Weight Kg 165 190 220 240 290
Air Circulation Type Fan Forced Fan Forced Fan Forced Fan Forced Fan Forced
Climate Class Rating 3M1 3M1 3M1 3M1 3M1
Range -1°C to +10°C -1°C to +10°C -1°C to +10°C -1°C to +10°C -1°C to +10°C
Temperature
Type Digital Digital Digital Digital Digital
Exterior Material Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Interior Material Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Colour Default Black Black Black Black Black
Voltage, V 220-240V 220-240V 220-240V 220-240V 220-240V
Electrical Frequency, Hz 50 50 50 50 50
Current, A 2.6 3.1 1.48 3.60 3.66
Energy Consumption kWh/24h 2.6 3.1 4.1 4.6 6.9
Internal Light Type LED LED LED LED LED
Shelves Qty 3 plus base 3 plus base 3 plus base 3 plus base 3 plus base
Solid/Glass Glass Glass Glass Glass Glass
Door Style Sliding Sliding Sliding Sliding Sliding
Self-Closing No No No No No
Door Lock No No No No No
Refrigeration Refrigerant R290 R290 R290 R290 R290
Plug Supplied 10A 10A 10A 10A 10A
Location Rear Rear Rear Rear Rear
Cord Length, m 2 2 2 2 2
Castors Available Yes Yes Yes Yes Yes

INSTALLATION

Locating the Cabinet
Ensure the following instructions are observed as this is vital for proper and trouble-free operation.

  • Do not install the cabinet outdoors.
  • Locate the appliance in a dry and well ventilated place.
  • The unit must be positioned on a level surface.
  • Do not install in the vicinity of heating radiators or other heat sources.
  • Do not install the appliance where it is exposed to direct sunlight.
  • Do not install the appliance where it is exposed to warm draughts or open doors.
  • Keep the air intake and outlets free of obstructions.
  • Adequate allowance should be made for door openings.BROMIC-REFREGERATION-SVM1875SD-NR-Semi-Vertical-Display-Fridge (4)

Ventilation
Ensure that the condenser fan is free to take in ambient air from the room.
Ensure the vents on top of the cabinet are clear at all times to disperse warm air

NOTE: The maximum ambient temperature for the refrigerator is 30°C. Conditions outside this temperature will result in cabinet temperatures outside the required 2 to 8°C range. Bromic recommends that the refrigerator is installed at an ambient temperature of 20 to 25°C.

Power Supply

  • The appliance must not be plugged into a multiple outlet power board.
  • The appliance is supplied with a flexible power cord fitted with a 3-pin plug.
  • The socket used must be properly earthed and fuse/RCD protected.
  • See the rating label inside the cabinet for supply voltage, frequency and current draw.
  • Power cable is rated 70°C. It is recommended that the cable should not come into contact with parts over 50°C.
  • Do not turn off power before consulting the person responsible.
  • Mark the power source clearly, so the refrigerator is not unplugged or turned off accidentally.BROMIC-REFREGERATION-SVM1875SD-NR-Semi-Vertical-Display-Fridge (5)

Before Operating

  • If the appliance has been sharply tilted or transported in the horizontal position, it must be left to stand in the upright position and not plugged in for at least 4 hours.
  • Remove all the packaging material before using the appliance.
  • Start the appliance only if it has been installed as described.

OPERATION

Start-up

  • Connect the appliance to the mains power supply.
  • The switches (image below) control cabinet cooling, defrost, and lights, respectively.
  • Flip all switches on for cabinet operation.
  • The compressor and condenser fan should operate should operate within 3 minutes after the Refrigeration switch is turned on.
  • The electronic controller will display the current cabinet temperature after the
  • Refrigeration switch is turned on.
  • The BROMIC-REFREGERATION-SVM1875SD-NR-Semi-Vertical-Display-Fridge (6)LED indicates that refrigeration circuit is operating.
  • During the start-up delay (3 minutes), the BROMIC-REFREGERATION-SVM1875SD-NR-Semi-Vertical-Display-Fridge (6)LED is flashing
  • The BROMIC-REFREGERATION-SVM1875SD-NR-Semi-Vertical-Display-Fridge (7)LED indicates that the refrigeration circuit is defrosting

Setting the temperature

BROMIC-REFREGERATION-SVM1875SD-NR-Semi-Vertical-Display-Fridge (8)

  1. Press the button for more than 3 seconds.
  2. The value of the set point will be displayed and the ‘°C’ or ‘°F’ LED starts blinking.
  3. PressBROMIC-REFREGERATION-SVM1875SD-NR-Semi-Vertical-Display-Fridge (9)arrow key within 10 seconds to adjust the set point.
  4. Press the key again or wait 10 seconds.

Cabinet Cooling On/O
Cabinet Lighting On/O

BROMIC-REFREGERATION-SVM1875SD-NR-Semi-Vertical-Display-Fridge (10)

PRODUCT LOADING AND STORAGE

IMPORTANT: Run the refrigerator for at least 2 hours before loading.
WARNING: : Do not store explosive substances such as aerosol cans with a flammable propellant inside the appliance.

Start-up

  • Clean the interior surface with a soft cloth and warm water before loading.
  • Ensure there is free circulation of air between the products.
  • Do not block the evaporator fan.
  • Keep refrigerator door openings to a minimum.
  • Some products are sensitive to ultraviolet (UV) light, please see storage guidelines from the manufacturer before removing from packaging.
  • Do not block the top or bottom grills when loading the cabinet. This can reduce cooling performance.
  • Do not overstock the cabinet: goods touching the cabinet walls and glass will not cool properly.

NOTE: Bromic cannot be responsible for loss of stock or damage to stock.

MAINTENANCE

  • WARNING: Disconnect the appliance from the power supply before performing any maintenance. Never unplug the appliance by pulling on the cord. Always grasp the plug firmly and pull straight out of the outlet.
  • WARNING: Exposure to significant water ingress will void warranty and cause potential safety issues. If the unit should be exposed to water, please contact the manufacturer immediately.
  • IMPORTANT: Warranty may be void if there is no evidence of preventative maintenance is performed on the appliance.

Cleaning the Cabinet

  • Remove the products and transfer to a suitable location prior to cleaning the inside of the cabinet.
  • Do not use any aggressive or abrasive cleaning agents.
  • Never use a water hose or a high-pressure jet to clean.
  • Do not use sharp or pointed objects for cleaning.
  • Clean the inside and outside of the appliance with a clean damp cloth or with a neutral cleanser.
  • Dry all surfaces with a dry cloth.

Condenser Coil/Filter
IMPORTANT: The filter and the condenser coil must be cleaned once a month.
The condenser coil must be cleaned with vacuum/brush monthly to maintain the performance and minimise power consumption. A poorly maintained condenser coil can lead to failure of the unit and higher cabinet temperatures.

General cleaning

  • The Semi-Vertical display must be wiped down regularly.
  • Preventing the build-up of oil and sediments will increase the longevity of the unit.

Condenser cleaning

  • A clogged condenser can result reduced cooling performance.
  • The condenser must be cleaned every 6 weeks.
  • Recommended cleaning methods includes:
  • Vacuum cleaner
  • Cleaning brush
  • Compressed air

Drain hose cleaning

  • The drainage hose must be kept clean and clear.
  • A clogged drainage hose can cause the unit to leak.

BROMIC-REFREGERATION-SVM1875SD-NR-Semi-Vertical-Display-Fridge (11)

TROUBLESHOOTING

IMPORTANT: Repairs on the unit must be carried out by an authorised and licensed person only. Contact the manufacturer or an approved service agent for any repairs needed.

BROMIC-REFREGERATION-SVM1875SD-NR-Semi-Vertical-Display-Fridge (12)

 

 MULTIPLEXING PROCEDURE

The multiplexing procedure can be used to connect multiple Bromic Semi Vertical units together.
A Bromic multiplexing kit must be used for this procedure.
The multiplexing procedure must be performed a licensed technician

BROMIC-REFREGERATION-SVM1875SD-NR-Semi-Vertical-Display-Fridge (13)

ALTERNATE CONFIGURATIONS

The Bromic Semi Vertical cabinet is available in alternate configurations upon special order. Contact your local Bromic sales representative for detailed information.

Default Configuration Alternate Configuration
Depth options Thin version (790mm depth) Wide version (930mm depth)
Door options Hinged doors Sliding doors

Open-front (no doors)

Colour options Black interior Alternate colours available upon
Black exterior special order
Black door frame
Black shelves
Black bumper

Product Specification for alternate options

Height, mm 1500 1500 1500 1500
Dimensions

(wide option)

Width, mm 1018 1330 1955 2580
Depth, mm 930 930 930 930
Net Volume Litres 478 678 956 1275
Solid/Glass Glass Glass Glass Glass
Sliding Door

(alternative

Type Sliding Sliding Sliding Sliding
option) Self-Closing No No No No
Door Lock No No No No
Voltage, V 230 230 230 230
Frequency, Hz 50 50 50 50
Nominal Power, W 816 1062 1625 2137
Electrical Door

(open-front

Rated Current, A 3.55 4.62 7.07 9.29
option) Fuse, A 16 16 16 16
Energy Consumption 11.92 14.4 17.8 24

ENVIRONMENTAL AND DISPOSAL NOTES

These refrigerated cabinets are designed to high standards of environmental protection and recycling convenience. Cyclopentane, an environmentally friendly foaming agent, has been used. Cyclopentane is distinguished by zero ozone depletion potential (ODP) and zero global warming potential (GWP). The refrigerant used and contained within a hermetically tight circuit is environmentally friendly and does not contain chlorine and zero ODP.
The device must be disposed of in accordance with applicable regulations. The WEEE regulations must be observed.
In the interest of preventing environmental nuisance and promoting re-use of the high quality materials employed, used commercial refrigeration equipment must be collected for expert disposal and recycling. Therefore, observe the following disposal regulations:

  • The cabinet must not be discarded with regular waste.
  • The refrigeration circuit must not be damaged.
  • Before disposal, make it unserviceable by disconnecting the power plug and cutting off the power cable.
  • Consult your local authorities or authorised dealers for details of collection and disposal facilities.
  • Children are often unable to recognise the dangers associated with commercial refrigeration equipment. Proper supervision must be maintained and children must be prevented from playing with discarded refrigerated cabinets.
  • The refrigerant used in all appliances covered by this manual are flammable.

WARRANTY

BROMIC-REFREGERATION-SVM1875SD-NR-Semi-Vertical-Display-Fridge (15)

All Bromic products are manufactured  to the highest quality standard and are supported by our Extra Care Service Warranty, including guarantees against any material or workmanship defects; guarantees that cannot be excluded under Australian Consumer Law.

Warranty Terms vary across the range. Please ensure you are familiar with the Terms and Conditions that apply to the purchase of your Bromic product by referring to the Warranty Policy included with your purchased product.
Alternatively, you can also download the Warranty Policy at   https://bromicrefrigeration.com.au/extra-care-warranty

HOW TO PLACE A SERVICE REQUEST

  • Please call 1300 276 642 to place a warranty service request and let the operator know whether you need Priority A or B service. More information can be found below.
  • Ensure you have the serial number of your product ready before contacting us.
  • The serial number of your product can be found on a compliance plate located on the inside right and at the rear of your cabinet.

BROMIC-REFREGERATION-SVM1875SD-NR-Semi-Vertical-Display-Fridge (1)

SERVICE REQUEST PRIORITY

  • PRIORITY A SERVICE
    When the unit is NOT performing its primary function such as cooling or heating, or presents an OH&S or food safety risk
  • PRIORITY B SERVICE
    When the unit is performing its primary function, and presents no OH&S or food safety risk. i.e. lights, gaskets. locks, door adjustment
  • SERVICE CALL PLACED BEFORE MIDDAY
    Priority A – Technician to attend site within 4 hours
    Priority B – Technician to attend site within 8 business hours
  • SERVICE CALL PLACED AFTER MIDDAY
    Priority A – Technician attends site before midday on the following business day
    Priority B – Technician attends site before 4pm on the following business day

BROMIC REFRIGERATION
10 Phiney Place, Ingleburn (Sydney) NSW 2565 Australia
T. 1300 276 642
For further product information bromicrefrigeration.com.au 

Documents / Resources

BROMIC REFREGERATION SVM1875SD-NR Semi Vertical Display Fridge [pdf] User Guide
SVM1875SD-NR, SVM1875SD-NR Semi Vertical Display Fridge, SVM1875SD-NR, Semi Vertical Display Fridge, Display Fridge, Fridge

References

Leave a comment

Your email address will not be published. Required fields are marked *